Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence

This article reviews the recent development of two solid-phase chemiluminescence-based techniques, fluorogenic-chemiluminescence (FCL) and electro-chemiluminescence (ECL) for detection of biological threat agents. Both techniques entail a labeled sandwich immunoassay. The objectives of this work are...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2000, Vol.14 (10), p.829-840
Hauptverfasser: Yu, H., Raymonda, J.W., McMahon, T.M., Campagnari, A.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 840
container_issue 10
container_start_page 829
container_title Biosensors & bioelectronics
container_volume 14
creator Yu, H.
Raymonda, J.W.
McMahon, T.M.
Campagnari, A.A.
description This article reviews the recent development of two solid-phase chemiluminescence-based techniques, fluorogenic-chemiluminescence (FCL) and electro-chemiluminescence (ECL) for detection of biological threat agents. Both techniques entail a labeled sandwich immunoassay. The objectives of this work are to develop advanced techniques for sensitive and effective detection of a target analyte, particularly in cases where the analysis includes complex samples containing multiple contaminating factors. Other important considerations in developing such detection techniques include the ease of use, the rapid determination of the results, and system automation for field applications. In FCL, alkaline phosphatase is used as a label and this technique utilizes the dual features of fluorescence and visual color generated upon the presence of the fluorogenic compound, AttoPhos ™. The assay reaction is determined by measuring the fluorescence. In ECL, the label is a ruthenium-trisbipyridal, which is excited to a higher energy state by an electric current-driven redox reaction, and the extent of the reaction is assessed via photon emission. Both techniques depend upon the magnetic separation technique as a means to isolate the target immunological agents from the sample for analysis. This magnetic capture system allows for a reaction to occur on the electron effective-transfer zone in the ECL and also provides the reaction site for the labeled sandwich in the FCL. Comparative studies of these two techniques for detection of biological threat agents have been performed and the advantages of using magnetic microspheres versus conventional solid-phase matrices are discussed.
doi_str_mv 10.1016/S0956-5663(99)00068-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71745576</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956566399000688</els_id><sourcerecordid>17560682</sourcerecordid><originalsourceid>FETCH-LOGICAL-c423t-418a6101d5d45abfda3352ed77ab02278f75756456ebf670027a581c1c2319833</originalsourceid><addsrcrecordid>eNqFkU9vFSEUxYmxsc_qR9CwMrqgwjDAsDJN_dekiQt1TRi48x4GhifMmHTXjy6vrzHu3oqQ_M49956D0CtGLxll8v13qoUkQkr-Vut3lFI5kOEJ2rBBcdJ3XDxFm3_IOXpe668GKabpM3TOqO5FL9QG3X-EBdwS8ozzhMeQY94GZyNedgXsgu0W5qXi8Q6HlNY5J7udYQkOp-BKrvsdFCCjreBxzTF4vN-1D57imktu2uAItrPHEJtLycTtIIW4pjBDdTA7eIHOJhsrvHx8L9DPz59-XH8lt9--3Fxf3RLXjllIzwYr2-Fe-F7YcfKWc9GBV8qOtOvUMCmhhOyFhHGSitJOWTEwx1zHmR44v0BvjnP3Jf9eoS4mhbZBjHaGvFajmOqFUPIk2Kl-4EqLkyBr-7RWugaKI3hIrBaYzL6EZMudYdQcyjQPZZpDU0Zr81CmGZru9aPBOibw_6mO7TXgwxGAFtyfAMVUFw6h-lBa3MbncMLiL1YRsHk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17560682</pqid></control><display><type>article</type><title>Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Yu, H. ; Raymonda, J.W. ; McMahon, T.M. ; Campagnari, A.A.</creator><creatorcontrib>Yu, H. ; Raymonda, J.W. ; McMahon, T.M. ; Campagnari, A.A.</creatorcontrib><description>This article reviews the recent development of two solid-phase chemiluminescence-based techniques, fluorogenic-chemiluminescence (FCL) and electro-chemiluminescence (ECL) for detection of biological threat agents. Both techniques entail a labeled sandwich immunoassay. The objectives of this work are to develop advanced techniques for sensitive and effective detection of a target analyte, particularly in cases where the analysis includes complex samples containing multiple contaminating factors. Other important considerations in developing such detection techniques include the ease of use, the rapid determination of the results, and system automation for field applications. In FCL, alkaline phosphatase is used as a label and this technique utilizes the dual features of fluorescence and visual color generated upon the presence of the fluorogenic compound, AttoPhos ™. The assay reaction is determined by measuring the fluorescence. In ECL, the label is a ruthenium-trisbipyridal, which is excited to a higher energy state by an electric current-driven redox reaction, and the extent of the reaction is assessed via photon emission. Both techniques depend upon the magnetic separation technique as a means to isolate the target immunological agents from the sample for analysis. This magnetic capture system allows for a reaction to occur on the electron effective-transfer zone in the ECL and also provides the reaction site for the labeled sandwich in the FCL. Comparative studies of these two techniques for detection of biological threat agents have been performed and the advantages of using magnetic microspheres versus conventional solid-phase matrices are discussed.</description><identifier>ISSN: 0956-5663</identifier><identifier>EISSN: 1873-4235</identifier><identifier>DOI: 10.1016/S0956-5663(99)00068-8</identifier><identifier>PMID: 10945457</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Biological detection ; Biological threat agent ; Biological Warfare ; biological warfare agents ; Biosensing Techniques ; Electro-chemiluminescence and fluorogenic-chemiluminescence ; Immunomagnetic Separation ; Luminescent Measurements ; Magnetic microspheres ; Solid-phase immunoassay</subject><ispartof>Biosensors &amp; bioelectronics, 2000, Vol.14 (10), p.829-840</ispartof><rights>2000 Elsevier Science S.A.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c423t-418a6101d5d45abfda3352ed77ab02278f75756456ebf670027a581c1c2319833</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0956566399000688$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,4009,27902,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10945457$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yu, H.</creatorcontrib><creatorcontrib>Raymonda, J.W.</creatorcontrib><creatorcontrib>McMahon, T.M.</creatorcontrib><creatorcontrib>Campagnari, A.A.</creatorcontrib><title>Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence</title><title>Biosensors &amp; bioelectronics</title><addtitle>Biosens Bioelectron</addtitle><description>This article reviews the recent development of two solid-phase chemiluminescence-based techniques, fluorogenic-chemiluminescence (FCL) and electro-chemiluminescence (ECL) for detection of biological threat agents. Both techniques entail a labeled sandwich immunoassay. The objectives of this work are to develop advanced techniques for sensitive and effective detection of a target analyte, particularly in cases where the analysis includes complex samples containing multiple contaminating factors. Other important considerations in developing such detection techniques include the ease of use, the rapid determination of the results, and system automation for field applications. In FCL, alkaline phosphatase is used as a label and this technique utilizes the dual features of fluorescence and visual color generated upon the presence of the fluorogenic compound, AttoPhos ™. The assay reaction is determined by measuring the fluorescence. In ECL, the label is a ruthenium-trisbipyridal, which is excited to a higher energy state by an electric current-driven redox reaction, and the extent of the reaction is assessed via photon emission. Both techniques depend upon the magnetic separation technique as a means to isolate the target immunological agents from the sample for analysis. This magnetic capture system allows for a reaction to occur on the electron effective-transfer zone in the ECL and also provides the reaction site for the labeled sandwich in the FCL. Comparative studies of these two techniques for detection of biological threat agents have been performed and the advantages of using magnetic microspheres versus conventional solid-phase matrices are discussed.</description><subject>Biological detection</subject><subject>Biological threat agent</subject><subject>Biological Warfare</subject><subject>biological warfare agents</subject><subject>Biosensing Techniques</subject><subject>Electro-chemiluminescence and fluorogenic-chemiluminescence</subject><subject>Immunomagnetic Separation</subject><subject>Luminescent Measurements</subject><subject>Magnetic microspheres</subject><subject>Solid-phase immunoassay</subject><issn>0956-5663</issn><issn>1873-4235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU9vFSEUxYmxsc_qR9CwMrqgwjDAsDJN_dekiQt1TRi48x4GhifMmHTXjy6vrzHu3oqQ_M49956D0CtGLxll8v13qoUkQkr-Vut3lFI5kOEJ2rBBcdJ3XDxFm3_IOXpe668GKabpM3TOqO5FL9QG3X-EBdwS8ozzhMeQY94GZyNedgXsgu0W5qXi8Q6HlNY5J7udYQkOp-BKrvsdFCCjreBxzTF4vN-1D57imktu2uAItrPHEJtLycTtIIW4pjBDdTA7eIHOJhsrvHx8L9DPz59-XH8lt9--3Fxf3RLXjllIzwYr2-Fe-F7YcfKWc9GBV8qOtOvUMCmhhOyFhHGSitJOWTEwx1zHmR44v0BvjnP3Jf9eoS4mhbZBjHaGvFajmOqFUPIk2Kl-4EqLkyBr-7RWugaKI3hIrBaYzL6EZMudYdQcyjQPZZpDU0Zr81CmGZru9aPBOibw_6mO7TXgwxGAFtyfAMVUFw6h-lBa3MbncMLiL1YRsHk</recordid><startdate>2000</startdate><enddate>2000</enddate><creator>Yu, H.</creator><creator>Raymonda, J.W.</creator><creator>McMahon, T.M.</creator><creator>Campagnari, A.A.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>7U5</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>2000</creationdate><title>Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence</title><author>Yu, H. ; Raymonda, J.W. ; McMahon, T.M. ; Campagnari, A.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c423t-418a6101d5d45abfda3352ed77ab02278f75756456ebf670027a581c1c2319833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Biological detection</topic><topic>Biological threat agent</topic><topic>Biological Warfare</topic><topic>biological warfare agents</topic><topic>Biosensing Techniques</topic><topic>Electro-chemiluminescence and fluorogenic-chemiluminescence</topic><topic>Immunomagnetic Separation</topic><topic>Luminescent Measurements</topic><topic>Magnetic microspheres</topic><topic>Solid-phase immunoassay</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yu, H.</creatorcontrib><creatorcontrib>Raymonda, J.W.</creatorcontrib><creatorcontrib>McMahon, T.M.</creatorcontrib><creatorcontrib>Campagnari, A.A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Biosensors &amp; bioelectronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yu, H.</au><au>Raymonda, J.W.</au><au>McMahon, T.M.</au><au>Campagnari, A.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence</atitle><jtitle>Biosensors &amp; bioelectronics</jtitle><addtitle>Biosens Bioelectron</addtitle><date>2000</date><risdate>2000</risdate><volume>14</volume><issue>10</issue><spage>829</spage><epage>840</epage><pages>829-840</pages><issn>0956-5663</issn><eissn>1873-4235</eissn><abstract>This article reviews the recent development of two solid-phase chemiluminescence-based techniques, fluorogenic-chemiluminescence (FCL) and electro-chemiluminescence (ECL) for detection of biological threat agents. Both techniques entail a labeled sandwich immunoassay. The objectives of this work are to develop advanced techniques for sensitive and effective detection of a target analyte, particularly in cases where the analysis includes complex samples containing multiple contaminating factors. Other important considerations in developing such detection techniques include the ease of use, the rapid determination of the results, and system automation for field applications. In FCL, alkaline phosphatase is used as a label and this technique utilizes the dual features of fluorescence and visual color generated upon the presence of the fluorogenic compound, AttoPhos ™. The assay reaction is determined by measuring the fluorescence. In ECL, the label is a ruthenium-trisbipyridal, which is excited to a higher energy state by an electric current-driven redox reaction, and the extent of the reaction is assessed via photon emission. Both techniques depend upon the magnetic separation technique as a means to isolate the target immunological agents from the sample for analysis. This magnetic capture system allows for a reaction to occur on the electron effective-transfer zone in the ECL and also provides the reaction site for the labeled sandwich in the FCL. Comparative studies of these two techniques for detection of biological threat agents have been performed and the advantages of using magnetic microspheres versus conventional solid-phase matrices are discussed.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>10945457</pmid><doi>10.1016/S0956-5663(99)00068-8</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0956-5663
ispartof Biosensors & bioelectronics, 2000, Vol.14 (10), p.829-840
issn 0956-5663
1873-4235
language eng
recordid cdi_proquest_miscellaneous_71745576
source MEDLINE; Elsevier ScienceDirect Journals
subjects Biological detection
Biological threat agent
Biological Warfare
biological warfare agents
Biosensing Techniques
Electro-chemiluminescence and fluorogenic-chemiluminescence
Immunomagnetic Separation
Luminescent Measurements
Magnetic microspheres
Solid-phase immunoassay
title Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T21%3A33%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20biological%20threat%20agents%20by%20immunomagnetic%20microsphere-based%20solid%20phase%20fluorogenic-%20and%20electro-chemiluminescence&rft.jtitle=Biosensors%20&%20bioelectronics&rft.au=Yu,%20H.&rft.date=2000&rft.volume=14&rft.issue=10&rft.spage=829&rft.epage=840&rft.pages=829-840&rft.issn=0956-5663&rft.eissn=1873-4235&rft_id=info:doi/10.1016/S0956-5663(99)00068-8&rft_dat=%3Cproquest_cross%3E17560682%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17560682&rft_id=info:pmid/10945457&rft_els_id=S0956566399000688&rfr_iscdi=true