Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system

The purpose of this study was to investigate the clinical application possibility of pure titanium konus telescope crowns fabricated using a CAD/CAM system. For the CAD/CAM system, Dental Cadim (Advance Co.) was used. For the material, exclusive pure titanium block for this system was used in this e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Dental materials journal 2008-03, Vol.27 (2), p.211-215
Hauptverfasser: Shimakura, Michio, Nagata, Tomohisa, Takeuchi, Misao, Nemoto, Toru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 215
container_issue 2
container_start_page 211
container_title Dental materials journal
container_volume 27
creator Shimakura, Michio
Nagata, Tomohisa
Takeuchi, Misao
Nemoto, Toru
description The purpose of this study was to investigate the clinical application possibility of pure titanium konus telescope crowns fabricated using a CAD/CAM system. For the CAD/CAM system, Dental Cadim (Advance Co.) was used. For the material, exclusive pure titanium block for this system was used in this experiment. Two types of experimental dies with different heights assumed the konus inner crown and three types of konus outer crowns with different gap widths at the occlusal part were prepared. The outer crown was seated on the inner crown die, and a load was applied perpendicularly to the upper surface of the outer crown for 10 seconds. Pullout test was performed at a crosshead speed of 5 mm/min, and the retentive force was measured. With increase in the height of the inner crown die and the applied load, the retentive force of konus telescope crown increased. Similarly, as the gap width at the occlusal part between the inner crown die and outer crown increased, the retentive force of konus telescope crown also increased.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_71655083</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71655083</sourcerecordid><originalsourceid>FETCH-LOGICAL-p544-ea3fb2089a9081cb7a0796b28435a468ffc21351c732a338c47025ff2161f08e3</originalsourceid><addsrcrecordid>eNo1kDtPwzAYAD2AaCn8BeSJLcLP2Bmr8ChSERKqxBg57mdkSOLgB6j_HiTKdMvphjtBS8K0qoQUaoHOU3onRDS11mdoQbUUhDdiiV5fIMOU_RdgF6IFHByeSwScfTaTLyP-CFNJOMMAyYYZsI3he0rYmT56azLscUl-esPt-vamXT_hdEgZxgt06syQ4PLIFdrd3-3aTbV9fnhs19tqlkJUYLjrGdGNaYimtleGqKbumRZcGlFr5yyjXFKrODOcaysUYdI5RmvqiAa-Qtd_2TmGzwIpd6NPFobBTBBK6hStpSSa_4pXR7H0I-y7OfrRxEP3f4L_APgFWLY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71655083</pqid></control><display><type>article</type><title>Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Shimakura, Michio ; Nagata, Tomohisa ; Takeuchi, Misao ; Nemoto, Toru</creator><creatorcontrib>Shimakura, Michio ; Nagata, Tomohisa ; Takeuchi, Misao ; Nemoto, Toru</creatorcontrib><description>The purpose of this study was to investigate the clinical application possibility of pure titanium konus telescope crowns fabricated using a CAD/CAM system. For the CAD/CAM system, Dental Cadim (Advance Co.) was used. For the material, exclusive pure titanium block for this system was used in this experiment. Two types of experimental dies with different heights assumed the konus inner crown and three types of konus outer crowns with different gap widths at the occlusal part were prepared. The outer crown was seated on the inner crown die, and a load was applied perpendicularly to the upper surface of the outer crown for 10 seconds. Pullout test was performed at a crosshead speed of 5 mm/min, and the retentive force was measured. With increase in the height of the inner crown die and the applied load, the retentive force of konus telescope crown increased. Similarly, as the gap width at the occlusal part between the inner crown die and outer crown increased, the retentive force of konus telescope crown also increased.</description><identifier>ISSN: 0287-4547</identifier><identifier>PMID: 18540394</identifier><language>eng</language><publisher>Japan</publisher><subject>Computer-Aided Design ; Crowns ; Dental Casting Technique ; Dental Prosthesis Design ; Dental Prosthesis Retention - instrumentation ; Dental Stress Analysis ; Dentistry ; Titanium</subject><ispartof>Dental materials journal, 2008-03, Vol.27 (2), p.211-215</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18540394$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shimakura, Michio</creatorcontrib><creatorcontrib>Nagata, Tomohisa</creatorcontrib><creatorcontrib>Takeuchi, Misao</creatorcontrib><creatorcontrib>Nemoto, Toru</creatorcontrib><title>Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system</title><title>Dental materials journal</title><addtitle>Dent Mater J</addtitle><description>The purpose of this study was to investigate the clinical application possibility of pure titanium konus telescope crowns fabricated using a CAD/CAM system. For the CAD/CAM system, Dental Cadim (Advance Co.) was used. For the material, exclusive pure titanium block for this system was used in this experiment. Two types of experimental dies with different heights assumed the konus inner crown and three types of konus outer crowns with different gap widths at the occlusal part were prepared. The outer crown was seated on the inner crown die, and a load was applied perpendicularly to the upper surface of the outer crown for 10 seconds. Pullout test was performed at a crosshead speed of 5 mm/min, and the retentive force was measured. With increase in the height of the inner crown die and the applied load, the retentive force of konus telescope crown increased. Similarly, as the gap width at the occlusal part between the inner crown die and outer crown increased, the retentive force of konus telescope crown also increased.</description><subject>Computer-Aided Design</subject><subject>Crowns</subject><subject>Dental Casting Technique</subject><subject>Dental Prosthesis Design</subject><subject>Dental Prosthesis Retention - instrumentation</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Titanium</subject><issn>0287-4547</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1kDtPwzAYAD2AaCn8BeSJLcLP2Bmr8ChSERKqxBg57mdkSOLgB6j_HiTKdMvphjtBS8K0qoQUaoHOU3onRDS11mdoQbUUhDdiiV5fIMOU_RdgF6IFHByeSwScfTaTLyP-CFNJOMMAyYYZsI3he0rYmT56azLscUl-esPt-vamXT_hdEgZxgt06syQ4PLIFdrd3-3aTbV9fnhs19tqlkJUYLjrGdGNaYimtleGqKbumRZcGlFr5yyjXFKrODOcaysUYdI5RmvqiAa-Qtd_2TmGzwIpd6NPFobBTBBK6hStpSSa_4pXR7H0I-y7OfrRxEP3f4L_APgFWLY</recordid><startdate>200803</startdate><enddate>200803</enddate><creator>Shimakura, Michio</creator><creator>Nagata, Tomohisa</creator><creator>Takeuchi, Misao</creator><creator>Nemoto, Toru</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200803</creationdate><title>Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system</title><author>Shimakura, Michio ; Nagata, Tomohisa ; Takeuchi, Misao ; Nemoto, Toru</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p544-ea3fb2089a9081cb7a0796b28435a468ffc21351c732a338c47025ff2161f08e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Computer-Aided Design</topic><topic>Crowns</topic><topic>Dental Casting Technique</topic><topic>Dental Prosthesis Design</topic><topic>Dental Prosthesis Retention - instrumentation</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Titanium</topic><toplevel>online_resources</toplevel><creatorcontrib>Shimakura, Michio</creatorcontrib><creatorcontrib>Nagata, Tomohisa</creatorcontrib><creatorcontrib>Takeuchi, Misao</creatorcontrib><creatorcontrib>Nemoto, Toru</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Dental materials journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shimakura, Michio</au><au>Nagata, Tomohisa</au><au>Takeuchi, Misao</au><au>Nemoto, Toru</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system</atitle><jtitle>Dental materials journal</jtitle><addtitle>Dent Mater J</addtitle><date>2008-03</date><risdate>2008</risdate><volume>27</volume><issue>2</issue><spage>211</spage><epage>215</epage><pages>211-215</pages><issn>0287-4547</issn><abstract>The purpose of this study was to investigate the clinical application possibility of pure titanium konus telescope crowns fabricated using a CAD/CAM system. For the CAD/CAM system, Dental Cadim (Advance Co.) was used. For the material, exclusive pure titanium block for this system was used in this experiment. Two types of experimental dies with different heights assumed the konus inner crown and three types of konus outer crowns with different gap widths at the occlusal part were prepared. The outer crown was seated on the inner crown die, and a load was applied perpendicularly to the upper surface of the outer crown for 10 seconds. Pullout test was performed at a crosshead speed of 5 mm/min, and the retentive force was measured. With increase in the height of the inner crown die and the applied load, the retentive force of konus telescope crown increased. Similarly, as the gap width at the occlusal part between the inner crown die and outer crown increased, the retentive force of konus telescope crown also increased.</abstract><cop>Japan</cop><pmid>18540394</pmid><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0287-4547
ispartof Dental materials journal, 2008-03, Vol.27 (2), p.211-215
issn 0287-4547
language eng
recordid cdi_proquest_miscellaneous_71655083
source J-STAGE Free; MEDLINE; Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals
subjects Computer-Aided Design
Crowns
Dental Casting Technique
Dental Prosthesis Design
Dental Prosthesis Retention - instrumentation
Dental Stress Analysis
Dentistry
Titanium
title Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T10%3A06%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Retentive%20force%20of%20pure%20titanium%20konus%20telescope%20crowns%20fabricated%20using%20CAD/CAM%20system&rft.jtitle=Dental%20materials%20journal&rft.au=Shimakura,%20Michio&rft.date=2008-03&rft.volume=27&rft.issue=2&rft.spage=211&rft.epage=215&rft.pages=211-215&rft.issn=0287-4547&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E71655083%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71655083&rft_id=info:pmid/18540394&rfr_iscdi=true