Comparison of techniques used to screen blood donations for malaria antibodies

In France all but one of the serological tests used to screen blood donations rely on ELISA-based techniques. The exception is malaria antibody detection that is performed by the indirect fluorescent antibody technique using commercially available kits. The reagent kit used at the French Army Blood...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Médecine tropicale 2003, Vol.63 (6), p.587-589
Hauptverfasser: Soler, C P, Gerome, P, Soullie, B, Tissedre, F, Bejan, H, Yvetot, J, Joussemet, M
Format: Magazinearticle
Sprache:fre
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 589
container_issue 6
container_start_page 587
container_title Médecine tropicale
container_volume 63
creator Soler, C P
Gerome, P
Soullie, B
Tissedre, F
Bejan, H
Yvetot, J
Joussemet, M
description In France all but one of the serological tests used to screen blood donations rely on ELISA-based techniques. The exception is malaria antibody detection that is performed by the indirect fluorescent antibody technique using commercially available kits. The reagent kit used at the French Army Blood Bank (FABB) is Falciparum-Spot IF (bioMerieux). However since the antigens in this kit are obtained from group A1 red blood cell cultures, false positive results can occur due to binding of natural antiglobulins. Over a 10-month period at the FABB, we disqualified a total of 55 donations (5.02% of total donations) because of positive Falciparum-Spot IF@1000 test results. Most disqualified donations (84%) involved donations with group O red blood cells. In the present retrospective study, these 55 disqualified donations were used to compare the specificity of three other serological tests used for detection of malaria antibodies: Falciparum-SpotIF after elimination of natural antiglobulins by absorption and neutralization with Witebski reagent and Paludix (Diagast). Use of all three techniques provided a specificity gain of over 87% but elimination using Witebski reagent led to a loss of sensitivity. At the FABB we have been using the Falciparum-Spot IF kit after elimination of natural antiglobulins since April 2001. Only 1.62% of donations tested have been disqualified due to the presence of malaria antibodies including 52% with group O red blood cells.
format Magazinearticle
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_71575439</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71575439</sourcerecordid><originalsourceid>FETCH-LOGICAL-p540-925e3d16f5ddd4cc61779ae2c9ee5996eefb33af7c458325f067f41ce98317283</originalsourceid><addsrcrecordid>eNo1kD1PwzAYhD2AaFX6F5Antkj-djyiii-pKksHtsixXwujxA52MvDvCaLccstzp9NdoS0hTDaqZe8btK_1k6xShBPJbtCGSqK1YGSLToc8TrbEmhPOAc_gPlL8WqDipYLHc8bVFYCE-yFnj31Odo45VRxywaMd1qjFNs2xzz5CvUXXwQ4V9hffofPT4_nw0hzfnl8PD8dmkoI0hkngnqogvffCOUW1NhaYMwDSGAUQes5t0E7IljMZiNJBUAem5VSzlu_Q_V_tVPLv2LkbY3UwDDZBXmqnqdRScLOCdxdw6Ufw3VTiaMt3938A_wHTyld9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>magazinearticle</recordtype><pqid>71575439</pqid></control><display><type>magazinearticle</type><title>Comparison of techniques used to screen blood donations for malaria antibodies</title><source>MEDLINE</source><source>Gallica Periodicals</source><creator>Soler, C P ; Gerome, P ; Soullie, B ; Tissedre, F ; Bejan, H ; Yvetot, J ; Joussemet, M</creator><creatorcontrib>Soler, C P ; Gerome, P ; Soullie, B ; Tissedre, F ; Bejan, H ; Yvetot, J ; Joussemet, M</creatorcontrib><description>In France all but one of the serological tests used to screen blood donations rely on ELISA-based techniques. The exception is malaria antibody detection that is performed by the indirect fluorescent antibody technique using commercially available kits. The reagent kit used at the French Army Blood Bank (FABB) is Falciparum-Spot IF (bioMerieux). However since the antigens in this kit are obtained from group A1 red blood cell cultures, false positive results can occur due to binding of natural antiglobulins. Over a 10-month period at the FABB, we disqualified a total of 55 donations (5.02% of total donations) because of positive Falciparum-Spot IF@1000 test results. Most disqualified donations (84%) involved donations with group O red blood cells. In the present retrospective study, these 55 disqualified donations were used to compare the specificity of three other serological tests used for detection of malaria antibodies: Falciparum-SpotIF after elimination of natural antiglobulins by absorption and neutralization with Witebski reagent and Paludix (Diagast). Use of all three techniques provided a specificity gain of over 87% but elimination using Witebski reagent led to a loss of sensitivity. At the FABB we have been using the Falciparum-Spot IF kit after elimination of natural antiglobulins since April 2001. Only 1.62% of donations tested have been disqualified due to the presence of malaria antibodies including 52% with group O red blood cells.</description><identifier>ISSN: 0025-682X</identifier><identifier>PMID: 15077420</identifier><language>fre</language><publisher>France</publisher><subject>Antibodies, Protozoan - analysis ; Blood Donors ; Blood Transfusion ; Enzyme-Linked Immunosorbent Assay ; Fluorescent Antibody Technique, Indirect ; Humans ; Malaria, Falciparum - diagnosis ; Malaria, Falciparum - prevention &amp; control ; Malaria, Falciparum - transmission ; Sensitivity and Specificity ; Serologic Tests</subject><ispartof>Médecine tropicale, 2003, Vol.63 (6), p.587-589</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15077420$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Soler, C P</creatorcontrib><creatorcontrib>Gerome, P</creatorcontrib><creatorcontrib>Soullie, B</creatorcontrib><creatorcontrib>Tissedre, F</creatorcontrib><creatorcontrib>Bejan, H</creatorcontrib><creatorcontrib>Yvetot, J</creatorcontrib><creatorcontrib>Joussemet, M</creatorcontrib><title>Comparison of techniques used to screen blood donations for malaria antibodies</title><title>Médecine tropicale</title><addtitle>Med Trop (Mars)</addtitle><description>In France all but one of the serological tests used to screen blood donations rely on ELISA-based techniques. The exception is malaria antibody detection that is performed by the indirect fluorescent antibody technique using commercially available kits. The reagent kit used at the French Army Blood Bank (FABB) is Falciparum-Spot IF (bioMerieux). However since the antigens in this kit are obtained from group A1 red blood cell cultures, false positive results can occur due to binding of natural antiglobulins. Over a 10-month period at the FABB, we disqualified a total of 55 donations (5.02% of total donations) because of positive Falciparum-Spot IF@1000 test results. Most disqualified donations (84%) involved donations with group O red blood cells. In the present retrospective study, these 55 disqualified donations were used to compare the specificity of three other serological tests used for detection of malaria antibodies: Falciparum-SpotIF after elimination of natural antiglobulins by absorption and neutralization with Witebski reagent and Paludix (Diagast). Use of all three techniques provided a specificity gain of over 87% but elimination using Witebski reagent led to a loss of sensitivity. At the FABB we have been using the Falciparum-Spot IF kit after elimination of natural antiglobulins since April 2001. Only 1.62% of donations tested have been disqualified due to the presence of malaria antibodies including 52% with group O red blood cells.</description><subject>Antibodies, Protozoan - analysis</subject><subject>Blood Donors</subject><subject>Blood Transfusion</subject><subject>Enzyme-Linked Immunosorbent Assay</subject><subject>Fluorescent Antibody Technique, Indirect</subject><subject>Humans</subject><subject>Malaria, Falciparum - diagnosis</subject><subject>Malaria, Falciparum - prevention &amp; control</subject><subject>Malaria, Falciparum - transmission</subject><subject>Sensitivity and Specificity</subject><subject>Serologic Tests</subject><issn>0025-682X</issn><fulltext>true</fulltext><rsrctype>magazinearticle</rsrctype><creationdate>2003</creationdate><recordtype>magazinearticle</recordtype><sourceid>EIF</sourceid><recordid>eNo1kD1PwzAYhD2AaFX6F5Antkj-djyiii-pKksHtsixXwujxA52MvDvCaLccstzp9NdoS0hTDaqZe8btK_1k6xShBPJbtCGSqK1YGSLToc8TrbEmhPOAc_gPlL8WqDipYLHc8bVFYCE-yFnj31Odo45VRxywaMd1qjFNs2xzz5CvUXXwQ4V9hffofPT4_nw0hzfnl8PD8dmkoI0hkngnqogvffCOUW1NhaYMwDSGAUQes5t0E7IljMZiNJBUAem5VSzlu_Q_V_tVPLv2LkbY3UwDDZBXmqnqdRScLOCdxdw6Ufw3VTiaMt3938A_wHTyld9</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Soler, C P</creator><creator>Gerome, P</creator><creator>Soullie, B</creator><creator>Tissedre, F</creator><creator>Bejan, H</creator><creator>Yvetot, J</creator><creator>Joussemet, M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>2003</creationdate><title>Comparison of techniques used to screen blood donations for malaria antibodies</title><author>Soler, C P ; Gerome, P ; Soullie, B ; Tissedre, F ; Bejan, H ; Yvetot, J ; Joussemet, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p540-925e3d16f5ddd4cc61779ae2c9ee5996eefb33af7c458325f067f41ce98317283</frbrgroupid><rsrctype>magazinearticle</rsrctype><prefilter>magazinearticle</prefilter><language>fre</language><creationdate>2003</creationdate><topic>Antibodies, Protozoan - analysis</topic><topic>Blood Donors</topic><topic>Blood Transfusion</topic><topic>Enzyme-Linked Immunosorbent Assay</topic><topic>Fluorescent Antibody Technique, Indirect</topic><topic>Humans</topic><topic>Malaria, Falciparum - diagnosis</topic><topic>Malaria, Falciparum - prevention &amp; control</topic><topic>Malaria, Falciparum - transmission</topic><topic>Sensitivity and Specificity</topic><topic>Serologic Tests</topic><toplevel>online_resources</toplevel><creatorcontrib>Soler, C P</creatorcontrib><creatorcontrib>Gerome, P</creatorcontrib><creatorcontrib>Soullie, B</creatorcontrib><creatorcontrib>Tissedre, F</creatorcontrib><creatorcontrib>Bejan, H</creatorcontrib><creatorcontrib>Yvetot, J</creatorcontrib><creatorcontrib>Joussemet, M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Médecine tropicale</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soler, C P</au><au>Gerome, P</au><au>Soullie, B</au><au>Tissedre, F</au><au>Bejan, H</au><au>Yvetot, J</au><au>Joussemet, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of techniques used to screen blood donations for malaria antibodies</atitle><jtitle>Médecine tropicale</jtitle><addtitle>Med Trop (Mars)</addtitle><date>2003</date><risdate>2003</risdate><volume>63</volume><issue>6</issue><spage>587</spage><epage>589</epage><pages>587-589</pages><issn>0025-682X</issn><abstract>In France all but one of the serological tests used to screen blood donations rely on ELISA-based techniques. The exception is malaria antibody detection that is performed by the indirect fluorescent antibody technique using commercially available kits. The reagent kit used at the French Army Blood Bank (FABB) is Falciparum-Spot IF (bioMerieux). However since the antigens in this kit are obtained from group A1 red blood cell cultures, false positive results can occur due to binding of natural antiglobulins. Over a 10-month period at the FABB, we disqualified a total of 55 donations (5.02% of total donations) because of positive Falciparum-Spot IF@1000 test results. Most disqualified donations (84%) involved donations with group O red blood cells. In the present retrospective study, these 55 disqualified donations were used to compare the specificity of three other serological tests used for detection of malaria antibodies: Falciparum-SpotIF after elimination of natural antiglobulins by absorption and neutralization with Witebski reagent and Paludix (Diagast). Use of all three techniques provided a specificity gain of over 87% but elimination using Witebski reagent led to a loss of sensitivity. At the FABB we have been using the Falciparum-Spot IF kit after elimination of natural antiglobulins since April 2001. Only 1.62% of donations tested have been disqualified due to the presence of malaria antibodies including 52% with group O red blood cells.</abstract><cop>France</cop><pmid>15077420</pmid><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0025-682X
ispartof Médecine tropicale, 2003, Vol.63 (6), p.587-589
issn 0025-682X
language fre
recordid cdi_proquest_miscellaneous_71575439
source MEDLINE; Gallica Periodicals
subjects Antibodies, Protozoan - analysis
Blood Donors
Blood Transfusion
Enzyme-Linked Immunosorbent Assay
Fluorescent Antibody Technique, Indirect
Humans
Malaria, Falciparum - diagnosis
Malaria, Falciparum - prevention & control
Malaria, Falciparum - transmission
Sensitivity and Specificity
Serologic Tests
title Comparison of techniques used to screen blood donations for malaria antibodies
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T08%3A48%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20techniques%20used%20to%20screen%20blood%20donations%20for%20malaria%20antibodies&rft.jtitle=M%C3%A9decine%20tropicale&rft.au=Soler,%20C%20P&rft.date=2003&rft.volume=63&rft.issue=6&rft.spage=587&rft.epage=589&rft.pages=587-589&rft.issn=0025-682X&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E71575439%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71575439&rft_id=info:pmid/15077420&rfr_iscdi=true