Electrically actuated, pressure-driven microfluidic pumps

In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2003-01, Vol.3 (4), p.217-220
Hauptverfasser: Munyan, Jason W, Fuentes, Hernan V, Draper, Melissa, Kelly, Ryan T, Woolley, Adam T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 220
container_issue 4
container_start_page 217
container_title Lab on a chip
container_volume 3
creator Munyan, Jason W
Fuentes, Hernan V
Draper, Melissa
Kelly, Ryan T
Woolley, Adam T
description In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.
doi_str_mv 10.1039/b309788a
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71544647</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71544647</sourcerecordid><originalsourceid>FETCH-LOGICAL-c336t-12a15234a2d8a64b6893204ce26228463841bcaa701d22aa4e367d402032ce4a3</originalsourceid><addsrcrecordid>eNpFkEtLxDAUhYMozjgK_gLpSlxYzatJupRhfMCAG12X2-QWIulMTRph_r2VGXV17-LjcM5HyCWjd4yK-r4VtNbGwBGZM6lFSZmpj__-Ws_IWUoflLJKKnNKZqyiVEtp5qReBbRj9BZC2BVgxwwjuttiiJhSjli66L9wU_Texm0XsnfeFkPuh3ROTjoICS8Od0HeH1dvy-dy_fr0snxYl1YINZaMA6u4kMCdASVbZWrBqbTIFedGKmEkay2ApsxxDiBRKO0k5VRwixLEglzvc4e4_cyYxqb3yWIIsMFtTo2eRkk1LV2Qmz04NU0pYtcM0fcQdw2jzY-m5lfThF4dMnPbo_sHD17EN3IyYQk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71544647</pqid></control><display><type>article</type><title>Electrically actuated, pressure-driven microfluidic pumps</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals</source><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Alma/SFX Local Collection</source><creator>Munyan, Jason W ; Fuentes, Hernan V ; Draper, Melissa ; Kelly, Ryan T ; Woolley, Adam T</creator><creatorcontrib>Munyan, Jason W ; Fuentes, Hernan V ; Draper, Melissa ; Kelly, Ryan T ; Woolley, Adam T</creatorcontrib><description>In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/b309788a</identifier><identifier>PMID: 15007448</identifier><language>eng</language><publisher>England</publisher><subject>Microcomputers ; Nanotechnology ; Polymethyl Methacrylate</subject><ispartof>Lab on a chip, 2003-01, Vol.3 (4), p.217-220</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c336t-12a15234a2d8a64b6893204ce26228463841bcaa701d22aa4e367d402032ce4a3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15007448$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Munyan, Jason W</creatorcontrib><creatorcontrib>Fuentes, Hernan V</creatorcontrib><creatorcontrib>Draper, Melissa</creatorcontrib><creatorcontrib>Kelly, Ryan T</creatorcontrib><creatorcontrib>Woolley, Adam T</creatorcontrib><title>Electrically actuated, pressure-driven microfluidic pumps</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.</description><subject>Microcomputers</subject><subject>Nanotechnology</subject><subject>Polymethyl Methacrylate</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkEtLxDAUhYMozjgK_gLpSlxYzatJupRhfMCAG12X2-QWIulMTRph_r2VGXV17-LjcM5HyCWjd4yK-r4VtNbGwBGZM6lFSZmpj__-Ws_IWUoflLJKKnNKZqyiVEtp5qReBbRj9BZC2BVgxwwjuttiiJhSjli66L9wU_Texm0XsnfeFkPuh3ROTjoICS8Od0HeH1dvy-dy_fr0snxYl1YINZaMA6u4kMCdASVbZWrBqbTIFedGKmEkay2ApsxxDiBRKO0k5VRwixLEglzvc4e4_cyYxqb3yWIIsMFtTo2eRkk1LV2Qmz04NU0pYtcM0fcQdw2jzY-m5lfThF4dMnPbo_sHD17EN3IyYQk</recordid><startdate>20030101</startdate><enddate>20030101</enddate><creator>Munyan, Jason W</creator><creator>Fuentes, Hernan V</creator><creator>Draper, Melissa</creator><creator>Kelly, Ryan T</creator><creator>Woolley, Adam T</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030101</creationdate><title>Electrically actuated, pressure-driven microfluidic pumps</title><author>Munyan, Jason W ; Fuentes, Hernan V ; Draper, Melissa ; Kelly, Ryan T ; Woolley, Adam T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c336t-12a15234a2d8a64b6893204ce26228463841bcaa701d22aa4e367d402032ce4a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Microcomputers</topic><topic>Nanotechnology</topic><topic>Polymethyl Methacrylate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Munyan, Jason W</creatorcontrib><creatorcontrib>Fuentes, Hernan V</creatorcontrib><creatorcontrib>Draper, Melissa</creatorcontrib><creatorcontrib>Kelly, Ryan T</creatorcontrib><creatorcontrib>Woolley, Adam T</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Munyan, Jason W</au><au>Fuentes, Hernan V</au><au>Draper, Melissa</au><au>Kelly, Ryan T</au><au>Woolley, Adam T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrically actuated, pressure-driven microfluidic pumps</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2003-01-01</date><risdate>2003</risdate><volume>3</volume><issue>4</issue><spage>217</spage><epage>220</epage><pages>217-220</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.</abstract><cop>England</cop><pmid>15007448</pmid><doi>10.1039/b309788a</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2003-01, Vol.3 (4), p.217-220
issn 1473-0197
1473-0189
language eng
recordid cdi_proquest_miscellaneous_71544647
source MEDLINE; Royal Society Of Chemistry Journals; Royal Society of Chemistry Journals Archive (1841-2007); Alma/SFX Local Collection
subjects Microcomputers
Nanotechnology
Polymethyl Methacrylate
title Electrically actuated, pressure-driven microfluidic pumps
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T18%3A19%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrically%20actuated,%20pressure-driven%20microfluidic%20pumps&rft.jtitle=Lab%20on%20a%20chip&rft.au=Munyan,%20Jason%20W&rft.date=2003-01-01&rft.volume=3&rft.issue=4&rft.spage=217&rft.epage=220&rft.pages=217-220&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/b309788a&rft_dat=%3Cproquest_cross%3E71544647%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71544647&rft_id=info:pmid/15007448&rfr_iscdi=true