D.I. Mendeleyev Institute for Metrology (VNIIM) participated in two international comparisons of 204Tl and 89Sr solutions organized by the BIPM. The activity concentration was measured using the 4 π PC β-counting method. Special attention was paid for investigating the dependence of the result on th...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 2002, Vol.56 (1), p.453-456 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 456 |
---|---|
container_issue | 1 |
container_start_page | 453 |
container_title | Applied radiation and isotopes |
container_volume | 56 |
creator | Sazonova, T.E. Kochin, A.E. Karmalitsyn, N.I. Sepman, S.V. Zanevsky, A.V. Shilnikova, T.I. |
description | D.I. Mendeleyev Institute for Metrology (VNIIM) participated in two international comparisons of
204Tl and
89Sr solutions organized by the BIPM. The activity concentration was measured using the 4
π PC
β-counting method. Special attention was paid for investigating the dependence of the result on the inner diameter of the source support ring. For thin Al rings (100–200
μm), no dependence was detected. The
β-impurities in the
89Sr solution were determined using a scintillation plastic spectrometer. The combined standard uncertainty of the standardization of the
89Sr solution is 0.2%, and that for
204Tl is 0.4%. |
doi_str_mv | 10.1016/S0969-8043(01)00230-5 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71452568</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804301002305</els_id><sourcerecordid>71452568</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2085-fb98780e66f985e7d1e7fbd497d8d206b2771fb88163c4300bddbbbbb7a65a093</originalsourceid><addsrcrecordid>eNqFkEtLw0AQxxdRbK1-BCUnUSE6u8m-TiLFR6HqodXrsq_ASprobiropzd9oEfnMjD8_jPMD6FjDJcYMLuagWQyF1AWZ4DPAUgBOd1BQyw4yaUA2EXDX2SADlJ6A4BSSLKPBhiLQgKlQ3Qx63TjdHThW3ehbbK2ygiU8zrrx5mQs5jpLnt9mkweD9Fepevkj7Z9hF7ubufjh3z6fD8Z30xzS0DQvDJScAGesUoK6rnDnlfGlZI74QgwQzjHlRECs8KWBYBxzqyKa0Y1yGKETjd732P7sfSpU4uQrK9r3fh2mRTHJSWUiR6kG9DGNqXoK_Uew0LHL4VBrSSptSS1MqAAq7UkRfvcyfbA0iy8-0ttrfTA9Qbw_ZufwUeVbPCN9S5Ebzvl2vDPiR8B2HNG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71452568</pqid></control><display><type>article</type><title>Standardization of 204Tl and 89Sr at VNIIM</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Sazonova, T.E. ; Kochin, A.E. ; Karmalitsyn, N.I. ; Sepman, S.V. ; Zanevsky, A.V. ; Shilnikova, T.I.</creator><creatorcontrib>Sazonova, T.E. ; Kochin, A.E. ; Karmalitsyn, N.I. ; Sepman, S.V. ; Zanevsky, A.V. ; Shilnikova, T.I.</creatorcontrib><description>D.I. Mendeleyev Institute for Metrology (VNIIM) participated in two international comparisons of
204Tl and
89Sr solutions organized by the BIPM. The activity concentration was measured using the 4
π PC
β-counting method. Special attention was paid for investigating the dependence of the result on the inner diameter of the source support ring. For thin Al rings (100–200
μm), no dependence was detected. The
β-impurities in the
89Sr solution were determined using a scintillation plastic spectrometer. The combined standard uncertainty of the standardization of the
89Sr solution is 0.2%, and that for
204Tl is 0.4%.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/S0969-8043(01)00230-5</identifier><identifier>PMID: 11839055</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><ispartof>Applied radiation and isotopes, 2002, Vol.56 (1), p.453-456</ispartof><rights>2002 Elsevier Science Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2085-fb98780e66f985e7d1e7fbd497d8d206b2771fb88163c4300bddbbbbb7a65a093</citedby><cites>FETCH-LOGICAL-c2085-fb98780e66f985e7d1e7fbd497d8d206b2771fb88163c4300bddbbbbb7a65a093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0969-8043(01)00230-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11839055$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sazonova, T.E.</creatorcontrib><creatorcontrib>Kochin, A.E.</creatorcontrib><creatorcontrib>Karmalitsyn, N.I.</creatorcontrib><creatorcontrib>Sepman, S.V.</creatorcontrib><creatorcontrib>Zanevsky, A.V.</creatorcontrib><creatorcontrib>Shilnikova, T.I.</creatorcontrib><title>Standardization of 204Tl and 89Sr at VNIIM</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>D.I. Mendeleyev Institute for Metrology (VNIIM) participated in two international comparisons of
204Tl and
89Sr solutions organized by the BIPM. The activity concentration was measured using the 4
π PC
β-counting method. Special attention was paid for investigating the dependence of the result on the inner diameter of the source support ring. For thin Al rings (100–200
μm), no dependence was detected. The
β-impurities in the
89Sr solution were determined using a scintillation plastic spectrometer. The combined standard uncertainty of the standardization of the
89Sr solution is 0.2%, and that for
204Tl is 0.4%.</description><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLw0AQxxdRbK1-BCUnUSE6u8m-TiLFR6HqodXrsq_ASprobiropzd9oEfnMjD8_jPMD6FjDJcYMLuagWQyF1AWZ4DPAUgBOd1BQyw4yaUA2EXDX2SADlJ6A4BSSLKPBhiLQgKlQ3Qx63TjdHThW3ehbbK2ygiU8zrrx5mQs5jpLnt9mkweD9Fepevkj7Z9hF7ubufjh3z6fD8Z30xzS0DQvDJScAGesUoK6rnDnlfGlZI74QgwQzjHlRECs8KWBYBxzqyKa0Y1yGKETjd732P7sfSpU4uQrK9r3fh2mRTHJSWUiR6kG9DGNqXoK_Uew0LHL4VBrSSptSS1MqAAq7UkRfvcyfbA0iy8-0ttrfTA9Qbw_ZufwUeVbPCN9S5Ebzvl2vDPiR8B2HNG</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Sazonova, T.E.</creator><creator>Kochin, A.E.</creator><creator>Karmalitsyn, N.I.</creator><creator>Sepman, S.V.</creator><creator>Zanevsky, A.V.</creator><creator>Shilnikova, T.I.</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2002</creationdate><title>Standardization of 204Tl and 89Sr at VNIIM</title><author>Sazonova, T.E. ; Kochin, A.E. ; Karmalitsyn, N.I. ; Sepman, S.V. ; Zanevsky, A.V. ; Shilnikova, T.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2085-fb98780e66f985e7d1e7fbd497d8d206b2771fb88163c4300bddbbbbb7a65a093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sazonova, T.E.</creatorcontrib><creatorcontrib>Kochin, A.E.</creatorcontrib><creatorcontrib>Karmalitsyn, N.I.</creatorcontrib><creatorcontrib>Sepman, S.V.</creatorcontrib><creatorcontrib>Zanevsky, A.V.</creatorcontrib><creatorcontrib>Shilnikova, T.I.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sazonova, T.E.</au><au>Kochin, A.E.</au><au>Karmalitsyn, N.I.</au><au>Sepman, S.V.</au><au>Zanevsky, A.V.</au><au>Shilnikova, T.I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Standardization of 204Tl and 89Sr at VNIIM</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2002</date><risdate>2002</risdate><volume>56</volume><issue>1</issue><spage>453</spage><epage>456</epage><pages>453-456</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>D.I. Mendeleyev Institute for Metrology (VNIIM) participated in two international comparisons of
204Tl and
89Sr solutions organized by the BIPM. The activity concentration was measured using the 4
π PC
β-counting method. Special attention was paid for investigating the dependence of the result on the inner diameter of the source support ring. For thin Al rings (100–200
μm), no dependence was detected. The
β-impurities in the
89Sr solution were determined using a scintillation plastic spectrometer. The combined standard uncertainty of the standardization of the
89Sr solution is 0.2%, and that for
204Tl is 0.4%.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>11839055</pmid><doi>10.1016/S0969-8043(01)00230-5</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0969-8043 |
ispartof | Applied radiation and isotopes, 2002, Vol.56 (1), p.453-456 |
issn | 0969-8043 1872-9800 |
language | eng |
recordid | cdi_proquest_miscellaneous_71452568 |
source | Elsevier ScienceDirect Journals Complete |
title | Standardization of 204Tl and 89Sr at VNIIM |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A13%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Standardization%20of%20204Tl%20and%2089Sr%20at%20VNIIM&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Sazonova,%20T.E.&rft.date=2002&rft.volume=56&rft.issue=1&rft.spage=453&rft.epage=456&rft.pages=453-456&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/S0969-8043(01)00230-5&rft_dat=%3Cproquest_cross%3E71452568%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71452568&rft_id=info:pmid/11839055&rft_els_id=S0969804301002305&rfr_iscdi=true |