Direct quantification of autologous serum albumin leakage after burn injury in mice

The current technique determining the extent of capillary leakage after injury is to measure the leakage of dye-labeled foreign albumin. A recent report, however, demonstrated that albumin leakage is dependent upon the type of fluorescent dye used for labeling. We chose to develop and test a techniq...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Burns 2002-02, Vol.28 (1), p.53-56
Hauptverfasser: Cho, Kiho, Adamson, Lee K., Hobson, Kristina G., Greenhalgh, David G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 56
container_issue 1
container_start_page 53
container_title Burns
container_volume 28
creator Cho, Kiho
Adamson, Lee K.
Hobson, Kristina G.
Greenhalgh, David G.
description The current technique determining the extent of capillary leakage after injury is to measure the leakage of dye-labeled foreign albumin. A recent report, however, demonstrated that albumin leakage is dependent upon the type of fluorescent dye used for labeling. We chose to develop and test a technique for determining the extent of vascular albumin leakage after burn injury without the use of dyes. Skin and blood samples were harvested at 3 h and 7 days after burn injury in mice. Total skin lysates and extracts as well as sera were analyzed for albumin leakage. Coomassie staining and Western blot analyses of skin preparations followed by the densitometric measurement revealed increased levels of albumin, suggesting that the leakage of serum albumin started within 3 h after burn injury. Instead of employing dye-labeled foreign albumin, the use of SDS-polyacrylamide gel electrophoresis of tissue extracts followed by Coomassie staining will allow for a simple and direct quantification of autologous albumin leakage due to burn as well as other types of injury.
doi_str_mv 10.1016/S0305-4179(01)00076-6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71449041</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0305417901000766</els_id><sourcerecordid>71449041</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-8b3cbfa0af8aec9dc6a503a9eb6f262e1610e5106efbbd030baed2f3da16e3a03</originalsourceid><addsrcrecordid>eNqFkMtOHDEQRS1EBBOSTyDyhihZdKgad3u6VygiTwmJBcnaKrvLyKQfYLcj8fcxMyNYZnU359bjCHGK8AkB9fkNKGiqGjfdB8CPALDRlT4QK2w3XYU1dIdi9Ywci9cp3RUImhaOxDFiq2qlYCVuvoTIbpEPmaYl-OBoCfMkZy8pL_Mw3845ycQxj5IGm8cwyYHpD92yJL9wlDbHSYbpLsfHEnIMjt-IV56GxG_3eSJ-f_v66_JHdXX9_efl56vKqQ6XqrXKWU9AviV2Xe80NaCoY6v9Wq8ZNQI3CJq9tX35xRL3a696Qs2KQJ2I97u593F-yJwWM4bkeBho4nK22WBdd1BjAZsd6OKcUmRv7mMYKT4aBPNk02xtmidVBtBsbRpdeu_2C7IduX9p7fUV4GwPUHI0-EiTC-mFU01T1neFu9hxXHT8DRxNcoEnx_3Wvunn8J9T_gFfQpLp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71449041</pqid></control><display><type>article</type><title>Direct quantification of autologous serum albumin leakage after burn injury in mice</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Cho, Kiho ; Adamson, Lee K. ; Hobson, Kristina G. ; Greenhalgh, David G.</creator><creatorcontrib>Cho, Kiho ; Adamson, Lee K. ; Hobson, Kristina G. ; Greenhalgh, David G.</creatorcontrib><description>The current technique determining the extent of capillary leakage after injury is to measure the leakage of dye-labeled foreign albumin. A recent report, however, demonstrated that albumin leakage is dependent upon the type of fluorescent dye used for labeling. We chose to develop and test a technique for determining the extent of vascular albumin leakage after burn injury without the use of dyes. Skin and blood samples were harvested at 3 h and 7 days after burn injury in mice. Total skin lysates and extracts as well as sera were analyzed for albumin leakage. Coomassie staining and Western blot analyses of skin preparations followed by the densitometric measurement revealed increased levels of albumin, suggesting that the leakage of serum albumin started within 3 h after burn injury. Instead of employing dye-labeled foreign albumin, the use of SDS-polyacrylamide gel electrophoresis of tissue extracts followed by Coomassie staining will allow for a simple and direct quantification of autologous albumin leakage due to burn as well as other types of injury.</description><identifier>ISSN: 0305-4179</identifier><identifier>EISSN: 1879-1409</identifier><identifier>DOI: 10.1016/S0305-4179(01)00076-6</identifier><identifier>PMID: 11834330</identifier><identifier>CODEN: BURND8</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Albumin ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Animals ; Biological and medical sciences ; Blotting, Western ; Burn injury ; Burns - blood ; Densitometry ; Disease Models, Animal ; Emergency and intensive care: burns ; Female ; Indicators and Reagents ; Intensive care medicine ; Medical sciences ; Mice ; Mice, Inbred C57BL ; Quantification ; Rosaniline Dyes ; Serum Albumin - analysis ; Severity of Illness Index ; Time Factors</subject><ispartof>Burns, 2002-02, Vol.28 (1), p.53-56</ispartof><rights>2002 Elsevier Science Ltd and ISBI</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-8b3cbfa0af8aec9dc6a503a9eb6f262e1610e5106efbbd030baed2f3da16e3a03</citedby><cites>FETCH-LOGICAL-c391t-8b3cbfa0af8aec9dc6a503a9eb6f262e1610e5106efbbd030baed2f3da16e3a03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0305-4179(01)00076-6$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13554139$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11834330$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Kiho</creatorcontrib><creatorcontrib>Adamson, Lee K.</creatorcontrib><creatorcontrib>Hobson, Kristina G.</creatorcontrib><creatorcontrib>Greenhalgh, David G.</creatorcontrib><title>Direct quantification of autologous serum albumin leakage after burn injury in mice</title><title>Burns</title><addtitle>Burns</addtitle><description>The current technique determining the extent of capillary leakage after injury is to measure the leakage of dye-labeled foreign albumin. A recent report, however, demonstrated that albumin leakage is dependent upon the type of fluorescent dye used for labeling. We chose to develop and test a technique for determining the extent of vascular albumin leakage after burn injury without the use of dyes. Skin and blood samples were harvested at 3 h and 7 days after burn injury in mice. Total skin lysates and extracts as well as sera were analyzed for albumin leakage. Coomassie staining and Western blot analyses of skin preparations followed by the densitometric measurement revealed increased levels of albumin, suggesting that the leakage of serum albumin started within 3 h after burn injury. Instead of employing dye-labeled foreign albumin, the use of SDS-polyacrylamide gel electrophoresis of tissue extracts followed by Coomassie staining will allow for a simple and direct quantification of autologous albumin leakage due to burn as well as other types of injury.</description><subject>Albumin</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Blotting, Western</subject><subject>Burn injury</subject><subject>Burns - blood</subject><subject>Densitometry</subject><subject>Disease Models, Animal</subject><subject>Emergency and intensive care: burns</subject><subject>Female</subject><subject>Indicators and Reagents</subject><subject>Intensive care medicine</subject><subject>Medical sciences</subject><subject>Mice</subject><subject>Mice, Inbred C57BL</subject><subject>Quantification</subject><subject>Rosaniline Dyes</subject><subject>Serum Albumin - analysis</subject><subject>Severity of Illness Index</subject><subject>Time Factors</subject><issn>0305-4179</issn><issn>1879-1409</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtOHDEQRS1EBBOSTyDyhihZdKgad3u6VygiTwmJBcnaKrvLyKQfYLcj8fcxMyNYZnU359bjCHGK8AkB9fkNKGiqGjfdB8CPALDRlT4QK2w3XYU1dIdi9Ywci9cp3RUImhaOxDFiq2qlYCVuvoTIbpEPmaYl-OBoCfMkZy8pL_Mw3845ycQxj5IGm8cwyYHpD92yJL9wlDbHSYbpLsfHEnIMjt-IV56GxG_3eSJ-f_v66_JHdXX9_efl56vKqQ6XqrXKWU9AviV2Xe80NaCoY6v9Wq8ZNQI3CJq9tX35xRL3a696Qs2KQJ2I97u593F-yJwWM4bkeBho4nK22WBdd1BjAZsd6OKcUmRv7mMYKT4aBPNk02xtmidVBtBsbRpdeu_2C7IduX9p7fUV4GwPUHI0-EiTC-mFU01T1neFu9hxXHT8DRxNcoEnx_3Wvunn8J9T_gFfQpLp</recordid><startdate>20020201</startdate><enddate>20020201</enddate><creator>Cho, Kiho</creator><creator>Adamson, Lee K.</creator><creator>Hobson, Kristina G.</creator><creator>Greenhalgh, David G.</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020201</creationdate><title>Direct quantification of autologous serum albumin leakage after burn injury in mice</title><author>Cho, Kiho ; Adamson, Lee K. ; Hobson, Kristina G. ; Greenhalgh, David G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-8b3cbfa0af8aec9dc6a503a9eb6f262e1610e5106efbbd030baed2f3da16e3a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Albumin</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Blotting, Western</topic><topic>Burn injury</topic><topic>Burns - blood</topic><topic>Densitometry</topic><topic>Disease Models, Animal</topic><topic>Emergency and intensive care: burns</topic><topic>Female</topic><topic>Indicators and Reagents</topic><topic>Intensive care medicine</topic><topic>Medical sciences</topic><topic>Mice</topic><topic>Mice, Inbred C57BL</topic><topic>Quantification</topic><topic>Rosaniline Dyes</topic><topic>Serum Albumin - analysis</topic><topic>Severity of Illness Index</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cho, Kiho</creatorcontrib><creatorcontrib>Adamson, Lee K.</creatorcontrib><creatorcontrib>Hobson, Kristina G.</creatorcontrib><creatorcontrib>Greenhalgh, David G.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Burns</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Kiho</au><au>Adamson, Lee K.</au><au>Hobson, Kristina G.</au><au>Greenhalgh, David G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct quantification of autologous serum albumin leakage after burn injury in mice</atitle><jtitle>Burns</jtitle><addtitle>Burns</addtitle><date>2002-02-01</date><risdate>2002</risdate><volume>28</volume><issue>1</issue><spage>53</spage><epage>56</epage><pages>53-56</pages><issn>0305-4179</issn><eissn>1879-1409</eissn><coden>BURND8</coden><abstract>The current technique determining the extent of capillary leakage after injury is to measure the leakage of dye-labeled foreign albumin. A recent report, however, demonstrated that albumin leakage is dependent upon the type of fluorescent dye used for labeling. We chose to develop and test a technique for determining the extent of vascular albumin leakage after burn injury without the use of dyes. Skin and blood samples were harvested at 3 h and 7 days after burn injury in mice. Total skin lysates and extracts as well as sera were analyzed for albumin leakage. Coomassie staining and Western blot analyses of skin preparations followed by the densitometric measurement revealed increased levels of albumin, suggesting that the leakage of serum albumin started within 3 h after burn injury. Instead of employing dye-labeled foreign albumin, the use of SDS-polyacrylamide gel electrophoresis of tissue extracts followed by Coomassie staining will allow for a simple and direct quantification of autologous albumin leakage due to burn as well as other types of injury.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>11834330</pmid><doi>10.1016/S0305-4179(01)00076-6</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0305-4179
ispartof Burns, 2002-02, Vol.28 (1), p.53-56
issn 0305-4179
1879-1409
language eng
recordid cdi_proquest_miscellaneous_71449041
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Albumin
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Animals
Biological and medical sciences
Blotting, Western
Burn injury
Burns - blood
Densitometry
Disease Models, Animal
Emergency and intensive care: burns
Female
Indicators and Reagents
Intensive care medicine
Medical sciences
Mice
Mice, Inbred C57BL
Quantification
Rosaniline Dyes
Serum Albumin - analysis
Severity of Illness Index
Time Factors
title Direct quantification of autologous serum albumin leakage after burn injury in mice
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T05%3A50%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20quantification%20of%20autologous%20serum%20albumin%20leakage%20after%20burn%20injury%20in%20mice&rft.jtitle=Burns&rft.au=Cho,%20Kiho&rft.date=2002-02-01&rft.volume=28&rft.issue=1&rft.spage=53&rft.epage=56&rft.pages=53-56&rft.issn=0305-4179&rft.eissn=1879-1409&rft.coden=BURND8&rft_id=info:doi/10.1016/S0305-4179(01)00076-6&rft_dat=%3Cproquest_cross%3E71449041%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71449041&rft_id=info:pmid/11834330&rft_els_id=S0305417901000766&rfr_iscdi=true