Purpose: The purpose of this research was to develop a quantitative real-time reverse transcription-PCR (RT-PCR) for CK19-mRNA and evaluate its clinical potential for the molecular detection of occult carcinoma cells in the peripheral blood of breast cancer patients. Experimental Design: The method...
Gespeichert in:
Veröffentlicht in: | Clinical cancer research 2003-11, Vol.9 (14), p.5145-5151 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: The purpose of this research was to develop a quantitative real-time reverse transcription-PCR (RT-PCR) for CK19-mRNA and
evaluate its clinical potential for the molecular detection of occult carcinoma cells in the peripheral blood of breast cancer
patients.
Experimental Design: The method is based on real-time monitoring during PCR of fluorescently labeled specific hybridization probes for CK19-mRNA.
The breast cancer cell line MCF-7 was used for the development and analytical evaluation of the assay. We analyzed blood samples
from 89 healthy blood donors, 77 patients with early breast cancer (stage I-II) postoperatively, and 47 patients with previously
untreated metastatic disease (stage IV) before and after chemotherapy. All of the samples were also analyzed by nested RT-PCR.
Results: The method is highly sensitive and specific, because only 2 of 89 (2.2%) of the healthy control subjects had detectable CK19-mRNA+
cells. In 77 patients with early breast cancer, CK19-mRNA+ cells were detected in 24 (31.2%) before and 5 (6.5%) after adjuvant
chemotherapy, and their levels differed significantly ( P < 0.001, Wilcoxon test). In 47 patients with verified metastases 19 (40.4%) and 20 (42.6%) were found positive before and
after chemotherapy, and no significant difference in CK19-mRNA+ cell levels was observed ( P = 0.96, Wilcoxon test). Results obtained by the proposed real-time RT-PCR method correlated well with those obtained for
the same samples by nested RT-PCR [concordance in 312 of 337 (92.6%); P = 0.69, McNemar test].
Conclusions: The developed method is highly sensitive and specific, and can be used for high-throughput continuous monitoring and quantification
of circulating epithelial cells in the peripheral blood of breast cancer patients. |
---|---|
ISSN: | 1078-0432 1557-3265 |