Polytetrafluoroethylene-covered stent for the treatment of narrowings in aorticocoronary saphenous vein grafts

We compared the outcome of patients with saphenous graft disease treated with polytetrafluoroethylene (PTFE)-covered stents or noncovered stents. Angiographic success was similar; non-Q-wave myocardial infarction was lower in the PTFE group (p = 0.06) and long-term major cardiac events and restenosi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology 2000-08, Vol.86 (3), p.343-346
Hauptverfasser: Briguori, C, De Gregorio, J, Nishida, T, Adamian, M, Albiero, R, Tucci, G, Di Mario, C, Colombo, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We compared the outcome of patients with saphenous graft disease treated with polytetrafluoroethylene (PTFE)-covered stents or noncovered stents. Angiographic success was similar; non-Q-wave myocardial infarction was lower in the PTFE group (p = 0.06) and long-term major cardiac events and restenosis rate were similar in the 2 groups. Implantation of PTFE-covered stent in vein graft disease seems to reduce the occurrence of distal embolization.
ISSN:0002-9149
DOI:10.1016/S0002-9149(00)00930-9