Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection

The possibility of using monosodium l-glutamate (MSG) (20 m M MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background cur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2000-06, Vol.881 (1), p.317-326
1. Verfasser: Iwase, Hiroshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 326
container_issue 1
container_start_page 317
container_title Journal of Chromatography A
container_volume 881
creator Iwase, Hiroshi
description The possibility of using monosodium l-glutamate (MSG) (20 m M MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background current were also examined. The applied potential was set at 400 mV versus an Ag/AgCl reference electrode. It was demonstrated that MSG was a useful mobile phase for the determination of AA in foods. This paper also examines the stability of AA under various conditions in order to optimize HPLC conditions and the pre-run sample stabilization. The proposed method is simple, rapid (analysis time: ∼6 min), sensitive (detection limit: ∼0.1 ng per injection (5 μl) at a signal-to-noise ratio of 3), highly selective and reproducible (relative standard deviation: ∼2.5%, n=7). The calibration graph of AA was linear in the range 0.1–50 ng per injection (5 μl). Recovery of AA was over 90% by the standard addition method.
doi_str_mv 10.1016/S0021-9673(00)00199-0
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71229260</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967300001990</els_id><sourcerecordid>71229260</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-91ff0085679f6a46b986feb54147338b1eb055e17701b27553b1d605f7f982033</originalsourceid><addsrcrecordid>eNqFkc1u2zAQhHlokaRJH6EFT0V7ULKUTNE8FUXQ_AAGckhyJkhqGbGQRJmUW_ht8qihZcPoLScCy292sDOEfGFwyYDVV48AJStkLarvAD8AmJQFfCBnx_Ep-ZTSn_whQJQn5JSBBC4YPyOvzwlpcFQPVPd-CFRb31A_0KlF2gfjO6RjqzPkQpyHDU4YM6onH4ZZmmyIxtuj1IXQULOlrX9pixFjVvZ6sEg7v95kxLYx9HoKL1GP7Zb-81NLsUM7xWBb7L3V3exidw4X5KPTXcLPh_ecPN_8frq-K1YPt_fXv1aFrSRMhWTOASx5LaSr9aI2clk7NHzBFqKqloahAc6RCQHMlILzyrCmBu6Ek8sSquqcfNvvHWNYbzBNqvfJYtfpAcMmKcHKUpY1ZJDvQRtDShGdGqPvddwqBmpXh5rrULvcFYCa61A73deDwcb02Pyn2neRgZ97APOZfz1GlazHnFvjY85CNcG_Y_EGXS6dzQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71229260</pqid></control><display><type>article</type><title>Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Iwase, Hiroshi</creator><creatorcontrib>Iwase, Hiroshi</creatorcontrib><description>The possibility of using monosodium l-glutamate (MSG) (20 m M MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background current were also examined. The applied potential was set at 400 mV versus an Ag/AgCl reference electrode. It was demonstrated that MSG was a useful mobile phase for the determination of AA in foods. This paper also examines the stability of AA under various conditions in order to optimize HPLC conditions and the pre-run sample stabilization. The proposed method is simple, rapid (analysis time: ∼6 min), sensitive (detection limit: ∼0.1 ng per injection (5 μl) at a signal-to-noise ratio of 3), highly selective and reproducible (relative standard deviation: ∼2.5%, n=7). The calibration graph of AA was linear in the range 0.1–50 ng per injection (5 μl). Recovery of AA was over 90% by the standard addition method.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/S0021-9673(00)00199-0</identifier><identifier>PMID: 10905715</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Amino acids ; Amino Acids - chemistry ; Ascorbic acid ; Ascorbic Acid - analysis ; Chromatography, High Pressure Liquid - methods ; Electrochemistry ; Food Analysis ; Monosodium glutamate ; Reproducibility of Results ; Sensitivity and Specificity ; Vitamins</subject><ispartof>Journal of Chromatography A, 2000-06, Vol.881 (1), p.317-326</ispartof><rights>2000 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-91ff0085679f6a46b986feb54147338b1eb055e17701b27553b1d605f7f982033</citedby><cites>FETCH-LOGICAL-c390t-91ff0085679f6a46b986feb54147338b1eb055e17701b27553b1d605f7f982033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0021-9673(00)00199-0$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10905715$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Iwase, Hiroshi</creatorcontrib><title>Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>The possibility of using monosodium l-glutamate (MSG) (20 m M MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background current were also examined. The applied potential was set at 400 mV versus an Ag/AgCl reference electrode. It was demonstrated that MSG was a useful mobile phase for the determination of AA in foods. This paper also examines the stability of AA under various conditions in order to optimize HPLC conditions and the pre-run sample stabilization. The proposed method is simple, rapid (analysis time: ∼6 min), sensitive (detection limit: ∼0.1 ng per injection (5 μl) at a signal-to-noise ratio of 3), highly selective and reproducible (relative standard deviation: ∼2.5%, n=7). The calibration graph of AA was linear in the range 0.1–50 ng per injection (5 μl). Recovery of AA was over 90% by the standard addition method.</description><subject>Amino acids</subject><subject>Amino Acids - chemistry</subject><subject>Ascorbic acid</subject><subject>Ascorbic Acid - analysis</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Electrochemistry</subject><subject>Food Analysis</subject><subject>Monosodium glutamate</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Vitamins</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkc1u2zAQhHlokaRJH6EFT0V7ULKUTNE8FUXQ_AAGckhyJkhqGbGQRJmUW_ht8qihZcPoLScCy292sDOEfGFwyYDVV48AJStkLarvAD8AmJQFfCBnx_Ep-ZTSn_whQJQn5JSBBC4YPyOvzwlpcFQPVPd-CFRb31A_0KlF2gfjO6RjqzPkQpyHDU4YM6onH4ZZmmyIxtuj1IXQULOlrX9pixFjVvZ6sEg7v95kxLYx9HoKL1GP7Zb-81NLsUM7xWBb7L3V3exidw4X5KPTXcLPh_ecPN_8frq-K1YPt_fXv1aFrSRMhWTOASx5LaSr9aI2clk7NHzBFqKqloahAc6RCQHMlILzyrCmBu6Ek8sSquqcfNvvHWNYbzBNqvfJYtfpAcMmKcHKUpY1ZJDvQRtDShGdGqPvddwqBmpXh5rrULvcFYCa61A73deDwcb02Pyn2neRgZ97APOZfz1GlazHnFvjY85CNcG_Y_EGXS6dzQ</recordid><startdate>20000609</startdate><enddate>20000609</enddate><creator>Iwase, Hiroshi</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000609</creationdate><title>Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection</title><author>Iwase, Hiroshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-91ff0085679f6a46b986feb54147338b1eb055e17701b27553b1d605f7f982033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Amino acids</topic><topic>Amino Acids - chemistry</topic><topic>Ascorbic acid</topic><topic>Ascorbic Acid - analysis</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Electrochemistry</topic><topic>Food Analysis</topic><topic>Monosodium glutamate</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Vitamins</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Iwase, Hiroshi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Iwase, Hiroshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2000-06-09</date><risdate>2000</risdate><volume>881</volume><issue>1</issue><spage>317</spage><epage>326</epage><pages>317-326</pages><issn>0021-9673</issn><abstract>The possibility of using monosodium l-glutamate (MSG) (20 m M MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background current were also examined. The applied potential was set at 400 mV versus an Ag/AgCl reference electrode. It was demonstrated that MSG was a useful mobile phase for the determination of AA in foods. This paper also examines the stability of AA under various conditions in order to optimize HPLC conditions and the pre-run sample stabilization. The proposed method is simple, rapid (analysis time: ∼6 min), sensitive (detection limit: ∼0.1 ng per injection (5 μl) at a signal-to-noise ratio of 3), highly selective and reproducible (relative standard deviation: ∼2.5%, n=7). The calibration graph of AA was linear in the range 0.1–50 ng per injection (5 μl). Recovery of AA was over 90% by the standard addition method.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>10905715</pmid><doi>10.1016/S0021-9673(00)00199-0</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2000-06, Vol.881 (1), p.317-326
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_71229260
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Amino acids
Amino Acids - chemistry
Ascorbic acid
Ascorbic Acid - analysis
Chromatography, High Pressure Liquid - methods
Electrochemistry
Food Analysis
Monosodium glutamate
Reproducibility of Results
Sensitivity and Specificity
Vitamins
title Use of an amino acid in the mobile phase for the determination of ascorbic acid in food by high-performance liquid chromatography with electrochemical detection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T22%3A54%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20an%20amino%20acid%20in%20the%20mobile%20phase%20for%20the%20determination%20of%20ascorbic%20acid%20in%20food%20by%20high-performance%20liquid%20chromatography%20with%20electrochemical%20detection&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Iwase,%20Hiroshi&rft.date=2000-06-09&rft.volume=881&rft.issue=1&rft.spage=317&rft.epage=326&rft.pages=317-326&rft.issn=0021-9673&rft_id=info:doi/10.1016/S0021-9673(00)00199-0&rft_dat=%3Cproquest_cross%3E71229260%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71229260&rft_id=info:pmid/10905715&rft_els_id=S0021967300001990&rfr_iscdi=true