Liquid chromatographic determination of less polar ginsenosides in processed ginseng
Reversed-phase LC with an evaporative light scattering detector (ELSD) is used for the determination of less polar ginsenosides in processed ginseng. These ginsenosides include ginsenosides F 4, Rg 3, Rg 5, Rg 6, Rk 1, Rk 3, Rs 3, Rs 4, and Rs 5. The method used a C 18-bonded silica column with a CH...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2001-07, Vol.921 (2), p.335-339 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 339 |
---|---|
container_issue | 2 |
container_start_page | 335 |
container_title | Journal of Chromatography A |
container_volume | 921 |
creator | Kwon, Sung Won Han, Sang Beom Park, Il Ho Kim, Jong Moon Park, Man Ki Park, Jeong Hill |
description | Reversed-phase LC with an evaporative light scattering detector (ELSD) is used for the determination of less polar ginsenosides in processed ginseng. These ginsenosides include ginsenosides F
4, Rg
3, Rg
5, Rg
6, Rk
1, Rk
3, Rs
3, Rs
4, and Rs
5. The method used a C
18-bonded silica column with a CH
3CN/H
2O/CH
3COOH gradient elution. (20
R) and (20
S) epimers and geometric isomers at the C-20 position of ginsenosides, which are not generally separated by amino columns, were now clearly separated. |
doi_str_mv | 10.1016/S0021-9673(01)00869-X |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71033726</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S002196730100869X</els_id><sourcerecordid>71033726</sourcerecordid><originalsourceid>FETCH-LOGICAL-c508t-8710ce6afc133f2fc96a03caeb39d4b3674c53eaa8a441513d9d9038fd16838d3</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhnNQbK3-BGUPInpYzTTbJHsSKX5BwYMVegtpMttGdjdtshX8927bRb15Gph55p3hIeQM6A1Q4LdvlA4hzblgVxSuKZU8T2cHpP_T7pHjGD8oBUHF8Ij0ADIBEmSfTCduvXE2McvgK934RdCrpTOJxQZD5WrdOF8nvkhKjDFZ-VKHZOHqiLWPzmJMXJ2sgjftFG03WZyQw0KXEU-7OiDvjw_T8XM6eX16Gd9PUjOiskmlAGqQ68IAY8WwMDnXlBmNc5bbbM64yMyIodZSZxmMgNnc5pTJwgKXTFo2IJf73PaD9QZjoyoXDZalrtFvomrzGRND3oKjPWiCjzFgoVbBVTp8KaBqq1DtFKqtK0VB7RSqWbt33h3YzCu0v1udvxa46AAdjS6LoGvj4p90zoXIW-xuj2Fr49NhUNE4rA1aF9A0ynr3zyffvpGRFA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71033726</pqid></control><display><type>article</type><title>Liquid chromatographic determination of less polar ginsenosides in processed ginseng</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Kwon, Sung Won ; Han, Sang Beom ; Park, Il Ho ; Kim, Jong Moon ; Park, Man Ki ; Park, Jeong Hill</creator><creatorcontrib>Kwon, Sung Won ; Han, Sang Beom ; Park, Il Ho ; Kim, Jong Moon ; Park, Man Ki ; Park, Jeong Hill</creatorcontrib><description>Reversed-phase LC with an evaporative light scattering detector (ELSD) is used for the determination of less polar ginsenosides in processed ginseng. These ginsenosides include ginsenosides F
4, Rg
3, Rg
5, Rg
6, Rk
1, Rk
3, Rs
3, Rs
4, and Rs
5. The method used a C
18-bonded silica column with a CH
3CN/H
2O/CH
3COOH gradient elution. (20
R) and (20
S) epimers and geometric isomers at the C-20 position of ginsenosides, which are not generally separated by amino columns, were now clearly separated.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/S0021-9673(01)00869-X</identifier><identifier>PMID: 11471818</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Chromatography, Liquid - methods ; General pharmacology ; Ginsenosides ; Medical sciences ; Panax - chemistry ; Pharmacognosy. Homeopathy. Health food ; Pharmacology. Drug treatments ; Saponins - analysis ; Spectrometry, Mass, Electrospray Ionization</subject><ispartof>Journal of Chromatography A, 2001-07, Vol.921 (2), p.335-339</ispartof><rights>2001 Elsevier Science B.V.</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c508t-8710ce6afc133f2fc96a03caeb39d4b3674c53eaa8a441513d9d9038fd16838d3</citedby><cites>FETCH-LOGICAL-c508t-8710ce6afc133f2fc96a03caeb39d4b3674c53eaa8a441513d9d9038fd16838d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0021-9673(01)00869-X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1066779$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11471818$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kwon, Sung Won</creatorcontrib><creatorcontrib>Han, Sang Beom</creatorcontrib><creatorcontrib>Park, Il Ho</creatorcontrib><creatorcontrib>Kim, Jong Moon</creatorcontrib><creatorcontrib>Park, Man Ki</creatorcontrib><creatorcontrib>Park, Jeong Hill</creatorcontrib><title>Liquid chromatographic determination of less polar ginsenosides in processed ginseng</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>Reversed-phase LC with an evaporative light scattering detector (ELSD) is used for the determination of less polar ginsenosides in processed ginseng. These ginsenosides include ginsenosides F
4, Rg
3, Rg
5, Rg
6, Rk
1, Rk
3, Rs
3, Rs
4, and Rs
5. The method used a C
18-bonded silica column with a CH
3CN/H
2O/CH
3COOH gradient elution. (20
R) and (20
S) epimers and geometric isomers at the C-20 position of ginsenosides, which are not generally separated by amino columns, were now clearly separated.</description><subject>Biological and medical sciences</subject><subject>Chromatography, Liquid - methods</subject><subject>General pharmacology</subject><subject>Ginsenosides</subject><subject>Medical sciences</subject><subject>Panax - chemistry</subject><subject>Pharmacognosy. Homeopathy. Health food</subject><subject>Pharmacology. Drug treatments</subject><subject>Saponins - analysis</subject><subject>Spectrometry, Mass, Electrospray Ionization</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LAzEQhnNQbK3-BGUPInpYzTTbJHsSKX5BwYMVegtpMttGdjdtshX8927bRb15Gph55p3hIeQM6A1Q4LdvlA4hzblgVxSuKZU8T2cHpP_T7pHjGD8oBUHF8Ij0ADIBEmSfTCduvXE2McvgK934RdCrpTOJxQZD5WrdOF8nvkhKjDFZ-VKHZOHqiLWPzmJMXJ2sgjftFG03WZyQw0KXEU-7OiDvjw_T8XM6eX16Gd9PUjOiskmlAGqQ68IAY8WwMDnXlBmNc5bbbM64yMyIodZSZxmMgNnc5pTJwgKXTFo2IJf73PaD9QZjoyoXDZalrtFvomrzGRND3oKjPWiCjzFgoVbBVTp8KaBqq1DtFKqtK0VB7RSqWbt33h3YzCu0v1udvxa46AAdjS6LoGvj4p90zoXIW-xuj2Fr49NhUNE4rA1aF9A0ynr3zyffvpGRFA</recordid><startdate>20010706</startdate><enddate>20010706</enddate><creator>Kwon, Sung Won</creator><creator>Han, Sang Beom</creator><creator>Park, Il Ho</creator><creator>Kim, Jong Moon</creator><creator>Park, Man Ki</creator><creator>Park, Jeong Hill</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010706</creationdate><title>Liquid chromatographic determination of less polar ginsenosides in processed ginseng</title><author>Kwon, Sung Won ; Han, Sang Beom ; Park, Il Ho ; Kim, Jong Moon ; Park, Man Ki ; Park, Jeong Hill</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c508t-8710ce6afc133f2fc96a03caeb39d4b3674c53eaa8a441513d9d9038fd16838d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Biological and medical sciences</topic><topic>Chromatography, Liquid - methods</topic><topic>General pharmacology</topic><topic>Ginsenosides</topic><topic>Medical sciences</topic><topic>Panax - chemistry</topic><topic>Pharmacognosy. Homeopathy. Health food</topic><topic>Pharmacology. Drug treatments</topic><topic>Saponins - analysis</topic><topic>Spectrometry, Mass, Electrospray Ionization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kwon, Sung Won</creatorcontrib><creatorcontrib>Han, Sang Beom</creatorcontrib><creatorcontrib>Park, Il Ho</creatorcontrib><creatorcontrib>Kim, Jong Moon</creatorcontrib><creatorcontrib>Park, Man Ki</creatorcontrib><creatorcontrib>Park, Jeong Hill</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kwon, Sung Won</au><au>Han, Sang Beom</au><au>Park, Il Ho</au><au>Kim, Jong Moon</au><au>Park, Man Ki</au><au>Park, Jeong Hill</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Liquid chromatographic determination of less polar ginsenosides in processed ginseng</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2001-07-06</date><risdate>2001</risdate><volume>921</volume><issue>2</issue><spage>335</spage><epage>339</epage><pages>335-339</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>Reversed-phase LC with an evaporative light scattering detector (ELSD) is used for the determination of less polar ginsenosides in processed ginseng. These ginsenosides include ginsenosides F
4, Rg
3, Rg
5, Rg
6, Rk
1, Rk
3, Rs
3, Rs
4, and Rs
5. The method used a C
18-bonded silica column with a CH
3CN/H
2O/CH
3COOH gradient elution. (20
R) and (20
S) epimers and geometric isomers at the C-20 position of ginsenosides, which are not generally separated by amino columns, were now clearly separated.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>11471818</pmid><doi>10.1016/S0021-9673(01)00869-X</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9673 |
ispartof | Journal of Chromatography A, 2001-07, Vol.921 (2), p.335-339 |
issn | 0021-9673 |
language | eng |
recordid | cdi_proquest_miscellaneous_71033726 |
source | MEDLINE; ScienceDirect Journals (5 years ago - present) |
subjects | Biological and medical sciences Chromatography, Liquid - methods General pharmacology Ginsenosides Medical sciences Panax - chemistry Pharmacognosy. Homeopathy. Health food Pharmacology. Drug treatments Saponins - analysis Spectrometry, Mass, Electrospray Ionization |
title | Liquid chromatographic determination of less polar ginsenosides in processed ginseng |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T15%3A46%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Liquid%20chromatographic%20determination%20of%20less%20polar%20ginsenosides%20in%20processed%20ginseng&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Kwon,%20Sung%20Won&rft.date=2001-07-06&rft.volume=921&rft.issue=2&rft.spage=335&rft.epage=339&rft.pages=335-339&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/S0021-9673(01)00869-X&rft_dat=%3Cproquest_cross%3E71033726%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71033726&rft_id=info:pmid/11471818&rft_els_id=S002196730100869X&rfr_iscdi=true |