Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor
Gespeichert in:
Veröffentlicht in: | Journal of the American Chemical Society 2001-04, Vol.123 (14), p.3383-3384 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3384 |
---|---|
container_issue | 14 |
container_start_page | 3383 |
container_title | Journal of the American Chemical Society |
container_volume | 123 |
creator | Shoji, Eiichi Freund, Michael S |
description | |
doi_str_mv | 10.1021/ja005906j |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_71020577</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71020577</sourcerecordid><originalsourceid>FETCH-LOGICAL-a169t-3ee928ab23050c0c737e43cc562c7dd8b4ba445e3b8eb2c601274a9f2307dca73</originalsourceid><addsrcrecordid>eNo9kE1Lw0AQQBdRbK0e_AOyF0UP0f1Isom3WmotFi2o52WzmWBKsluzG6GevPo3_SWmtPU0zPB4DA-hU0quKWH0ZqEIiVISL_ZQn0aMBBFl8T7qE0JYIJKY99CRc4tuDVlCD1GP0jASJKF95ObWg_GlrcE3pcYvYJxtHL5TDnJsDfbvgKcmb7UvPwGPiwK0392Xj1hhW-C5rVaXypRVaeDq9vf7Bw_xkzVgvla18p11UrXaOtjaj9FBoSoHJ9s5QG_349fRQzB7nkxHw1mgaJz6gAOkLFEZ4yQimmjBBYRc6yhmWuR5koWZCsMIeJZAxnRMKBOhSouOF7lWgg_Qxca7bOxHC87LunQaqkoZsK2TootHIrEGz7Zgm9WQy2VT1qpZyV2mDjjfAEo7ubBtY7q_JSVynV_-5-d_mX51Yw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71020577</pqid></control><display><type>article</type><title>Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor</title><source>MEDLINE</source><source>ACS Publications</source><creator>Shoji, Eiichi ; Freund, Michael S</creator><creatorcontrib>Shoji, Eiichi ; Freund, Michael S</creatorcontrib><identifier>ISSN: 0002-7863</identifier><identifier>EISSN: 1520-5126</identifier><identifier>DOI: 10.1021/ja005906j</identifier><identifier>PMID: 11457081</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Aniline Compounds - chemistry ; Biosensing Techniques - methods ; Boronic Acids - chemistry ; Electrochemistry - methods ; Glucose - analysis ; Kinetics ; Potentiometry - methods</subject><ispartof>Journal of the American Chemical Society, 2001-04, Vol.123 (14), p.3383-3384</ispartof><rights>Copyright © 2001 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ja005906j$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ja005906j$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,27074,27922,27923,56736,56786</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11457081$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shoji, Eiichi</creatorcontrib><creatorcontrib>Freund, Michael S</creatorcontrib><title>Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor</title><title>Journal of the American Chemical Society</title><addtitle>J. Am. Chem. Soc</addtitle><subject>Aniline Compounds - chemistry</subject><subject>Biosensing Techniques - methods</subject><subject>Boronic Acids - chemistry</subject><subject>Electrochemistry - methods</subject><subject>Glucose - analysis</subject><subject>Kinetics</subject><subject>Potentiometry - methods</subject><issn>0002-7863</issn><issn>1520-5126</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kE1Lw0AQQBdRbK0e_AOyF0UP0f1Isom3WmotFi2o52WzmWBKsluzG6GevPo3_SWmtPU0zPB4DA-hU0quKWH0ZqEIiVISL_ZQn0aMBBFl8T7qE0JYIJKY99CRc4tuDVlCD1GP0jASJKF95ObWg_GlrcE3pcYvYJxtHL5TDnJsDfbvgKcmb7UvPwGPiwK0392Xj1hhW-C5rVaXypRVaeDq9vf7Bw_xkzVgvla18p11UrXaOtjaj9FBoSoHJ9s5QG_349fRQzB7nkxHw1mgaJz6gAOkLFEZ4yQimmjBBYRc6yhmWuR5koWZCsMIeJZAxnRMKBOhSouOF7lWgg_Qxca7bOxHC87LunQaqkoZsK2TootHIrEGz7Zgm9WQy2VT1qpZyV2mDjjfAEo7ubBtY7q_JSVynV_-5-d_mX51Yw</recordid><startdate>20010411</startdate><enddate>20010411</enddate><creator>Shoji, Eiichi</creator><creator>Freund, Michael S</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20010411</creationdate><title>Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor</title><author>Shoji, Eiichi ; Freund, Michael S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a169t-3ee928ab23050c0c737e43cc562c7dd8b4ba445e3b8eb2c601274a9f2307dca73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Aniline Compounds - chemistry</topic><topic>Biosensing Techniques - methods</topic><topic>Boronic Acids - chemistry</topic><topic>Electrochemistry - methods</topic><topic>Glucose - analysis</topic><topic>Kinetics</topic><topic>Potentiometry - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shoji, Eiichi</creatorcontrib><creatorcontrib>Freund, Michael S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shoji, Eiichi</au><au>Freund, Michael S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor</atitle><jtitle>Journal of the American Chemical Society</jtitle><addtitle>J. Am. Chem. Soc</addtitle><date>2001-04-11</date><risdate>2001</risdate><volume>123</volume><issue>14</issue><spage>3383</spage><epage>3384</epage><pages>3383-3384</pages><issn>0002-7863</issn><eissn>1520-5126</eissn><cop>United States</cop><pub>American Chemical Society</pub><pmid>11457081</pmid><doi>10.1021/ja005906j</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0002-7863 |
ispartof | Journal of the American Chemical Society, 2001-04, Vol.123 (14), p.3383-3384 |
issn | 0002-7863 1520-5126 |
language | eng |
recordid | cdi_proquest_miscellaneous_71020577 |
source | MEDLINE; ACS Publications |
subjects | Aniline Compounds - chemistry Biosensing Techniques - methods Boronic Acids - chemistry Electrochemistry - methods Glucose - analysis Kinetics Potentiometry - methods |
title | Potentiometric Sensors Based on the Inductive Effect on the pK a of Poly(aniline): A Nonenzymatic Glucose Sensor |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T12%3A59%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Potentiometric%20Sensors%20Based%20on%20the%20Inductive%20Effect%20on%20the%20pK%20a%20of%20Poly(aniline):%E2%80%89%20A%20Nonenzymatic%20Glucose%20Sensor&rft.jtitle=Journal%20of%20the%20American%20Chemical%20Society&rft.au=Shoji,%20Eiichi&rft.date=2001-04-11&rft.volume=123&rft.issue=14&rft.spage=3383&rft.epage=3384&rft.pages=3383-3384&rft.issn=0002-7863&rft.eissn=1520-5126&rft_id=info:doi/10.1021/ja005906j&rft_dat=%3Cproquest_pubme%3E71020577%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71020577&rft_id=info:pmid/11457081&rfr_iscdi=true |