Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles
We compared the biomechanical stability of 60° and 90° angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5mm advancements, the osteotomies were fixed with screws 2mm in diameter inserted with a torque control screwdriver at...
Gespeichert in:
Veröffentlicht in: | British journal of oral & maxillofacial surgery 2001-08, Vol.39 (4), p.266-268 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 268 |
---|---|
container_issue | 4 |
container_start_page | 266 |
container_title | British journal of oral & maxillofacial surgery |
container_volume | 39 |
creator | Uckan, S. Schwimmer, A. Kummer, F. Greenberg, A.M. |
description | We compared the biomechanical stability of 60° and 90° angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5mm advancements, the osteotomies were fixed with screws 2mm in diameter inserted with a torque control screwdriver at either 60° or 90° to the long axis of bone, in a matched pair experimental design. All specimens were then loaded in a physiological manner and the load-displacement of the osteotomies was recorded. Data for resistance to movement were compared by a paired t -test. The mean (SD) resistance to movement for the 60° and 90° screw insertions was 63.4 (27.7) N/mm and 59 (22.3) N/mm respectively. There was no significant difference between the groups. This correlates with clinical findings. |
doi_str_mv | 10.1054/bjom.2000.0580 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70981383</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0266435600905801</els_id><sourcerecordid>70981383</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-9e32fc97747b13531371a67b6674157d403ccaee50e794b256cc1aded8f118863</originalsourceid><addsrcrecordid>eNp1kU1v1DAQhi0EokvhyhH5gLhlseOvhBuqyodUiQucLceZtK6cePE4VHvht-PVpoILJ2vk5301eoaQ15ztOVPy_XCf5n3LGNsz1bEnZMeVaBveS_aU7FirdSOF0hfkBeJ9pVTL1XNywbkURrZ8R35fTxP4QtNEyx1Qt9xGeBzQZ3igaTkPxQ0hhnJ8_J3dMoZhjS5TdLehFBcpHipBs5tXpAkLpJLm4wfqanodjzQsFO8ADls2Ar4kzyYXEV5t7yX58en6-9WX5ubb569XH28aL3Rfmh5EO_neGGkGLpTgwnCnzaC1kVyZUTLhvQNQDEwvh1Zp77kbYewmzrtOi0vy7tx7yOnnCljsHNBDjG6BtKI1rO-46EQF92fQ54SYYbKHHGaXj5YzezJuT8btybg9Ga-BN1vzOsww_sU3xRV4uwEOvYtTdosP-E9tZ1ppKtadMagafgXIFn2AxcMYcj2QHVP43wp_AOC4nRk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70981383</pqid></control><display><type>article</type><title>Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Uckan, S. ; Schwimmer, A. ; Kummer, F. ; Greenberg, A.M.</creator><creatorcontrib>Uckan, S. ; Schwimmer, A. ; Kummer, F. ; Greenberg, A.M.</creatorcontrib><description>We compared the biomechanical stability of 60° and 90° angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5mm advancements, the osteotomies were fixed with screws 2mm in diameter inserted with a torque control screwdriver at either 60° or 90° to the long axis of bone, in a matched pair experimental design. All specimens were then loaded in a physiological manner and the load-displacement of the osteotomies was recorded. Data for resistance to movement were compared by a paired t -test. The mean (SD) resistance to movement for the 60° and 90° screw insertions was 63.4 (27.7) N/mm and 59 (22.3) N/mm respectively. There was no significant difference between the groups. This correlates with clinical findings.</description><identifier>ISSN: 0266-4356</identifier><identifier>EISSN: 1532-1940</identifier><identifier>DOI: 10.1054/bjom.2000.0580</identifier><identifier>PMID: 11437421</identifier><identifier>CODEN: BJOSEY</identifier><language>eng</language><publisher>Londonc: Elsevier Ltd</publisher><subject>Animals ; Biological and medical sciences ; Biomechanical Phenomena ; Bone Screws ; Dental Stress Analysis ; Dentistry ; Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics ; Jaw Fixation Techniques - instrumentation ; Mandible - surgery ; Maxillofacial surgery. Dental surgery. Orthodontics ; Medical sciences ; Osteotomy - instrumentation ; Osteotomy - methods ; Sheep ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><ispartof>British journal of oral & maxillofacial surgery, 2001-08, Vol.39 (4), p.266-268</ispartof><rights>2001 The British Association of Oral and Maxillofacial Surgeons</rights><rights>2001 INIST-CNRS</rights><rights>Copyright 2001 The British Association of Oral and Maxillofacial Surgeons.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-9e32fc97747b13531371a67b6674157d403ccaee50e794b256cc1aded8f118863</citedby><cites>FETCH-LOGICAL-c369t-9e32fc97747b13531371a67b6674157d403ccaee50e794b256cc1aded8f118863</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0266435600905801$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1087247$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11437421$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Uckan, S.</creatorcontrib><creatorcontrib>Schwimmer, A.</creatorcontrib><creatorcontrib>Kummer, F.</creatorcontrib><creatorcontrib>Greenberg, A.M.</creatorcontrib><title>Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles</title><title>British journal of oral & maxillofacial surgery</title><addtitle>Br J Oral Maxillofac Surg</addtitle><description>We compared the biomechanical stability of 60° and 90° angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5mm advancements, the osteotomies were fixed with screws 2mm in diameter inserted with a torque control screwdriver at either 60° or 90° to the long axis of bone, in a matched pair experimental design. All specimens were then loaded in a physiological manner and the load-displacement of the osteotomies was recorded. Data for resistance to movement were compared by a paired t -test. The mean (SD) resistance to movement for the 60° and 90° screw insertions was 63.4 (27.7) N/mm and 59 (22.3) N/mm respectively. There was no significant difference between the groups. This correlates with clinical findings.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Biomechanical Phenomena</subject><subject>Bone Screws</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics</subject><subject>Jaw Fixation Techniques - instrumentation</subject><subject>Mandible - surgery</subject><subject>Maxillofacial surgery. Dental surgery. Orthodontics</subject><subject>Medical sciences</subject><subject>Osteotomy - instrumentation</subject><subject>Osteotomy - methods</subject><subject>Sheep</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><issn>0266-4356</issn><issn>1532-1940</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kU1v1DAQhi0EokvhyhH5gLhlseOvhBuqyodUiQucLceZtK6cePE4VHvht-PVpoILJ2vk5301eoaQ15ztOVPy_XCf5n3LGNsz1bEnZMeVaBveS_aU7FirdSOF0hfkBeJ9pVTL1XNywbkURrZ8R35fTxP4QtNEyx1Qt9xGeBzQZ3igaTkPxQ0hhnJ8_J3dMoZhjS5TdLehFBcpHipBs5tXpAkLpJLm4wfqanodjzQsFO8ADls2Ar4kzyYXEV5t7yX58en6-9WX5ubb569XH28aL3Rfmh5EO_neGGkGLpTgwnCnzaC1kVyZUTLhvQNQDEwvh1Zp77kbYewmzrtOi0vy7tx7yOnnCljsHNBDjG6BtKI1rO-46EQF92fQ54SYYbKHHGaXj5YzezJuT8btybg9Ga-BN1vzOsww_sU3xRV4uwEOvYtTdosP-E9tZ1ppKtadMagafgXIFn2AxcMYcj2QHVP43wp_AOC4nRk</recordid><startdate>20010801</startdate><enddate>20010801</enddate><creator>Uckan, S.</creator><creator>Schwimmer, A.</creator><creator>Kummer, F.</creator><creator>Greenberg, A.M.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010801</creationdate><title>Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles</title><author>Uckan, S. ; Schwimmer, A. ; Kummer, F. ; Greenberg, A.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-9e32fc97747b13531371a67b6674157d403ccaee50e794b256cc1aded8f118863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Biomechanical Phenomena</topic><topic>Bone Screws</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics</topic><topic>Jaw Fixation Techniques - instrumentation</topic><topic>Mandible - surgery</topic><topic>Maxillofacial surgery. Dental surgery. Orthodontics</topic><topic>Medical sciences</topic><topic>Osteotomy - instrumentation</topic><topic>Osteotomy - methods</topic><topic>Sheep</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Uckan, S.</creatorcontrib><creatorcontrib>Schwimmer, A.</creatorcontrib><creatorcontrib>Kummer, F.</creatorcontrib><creatorcontrib>Greenberg, A.M.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>British journal of oral & maxillofacial surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Uckan, S.</au><au>Schwimmer, A.</au><au>Kummer, F.</au><au>Greenberg, A.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles</atitle><jtitle>British journal of oral & maxillofacial surgery</jtitle><addtitle>Br J Oral Maxillofac Surg</addtitle><date>2001-08-01</date><risdate>2001</risdate><volume>39</volume><issue>4</issue><spage>266</spage><epage>268</epage><pages>266-268</pages><issn>0266-4356</issn><eissn>1532-1940</eissn><coden>BJOSEY</coden><abstract>We compared the biomechanical stability of 60° and 90° angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5mm advancements, the osteotomies were fixed with screws 2mm in diameter inserted with a torque control screwdriver at either 60° or 90° to the long axis of bone, in a matched pair experimental design. All specimens were then loaded in a physiological manner and the load-displacement of the osteotomies was recorded. Data for resistance to movement were compared by a paired t -test. The mean (SD) resistance to movement for the 60° and 90° screw insertions was 63.4 (27.7) N/mm and 59 (22.3) N/mm respectively. There was no significant difference between the groups. This correlates with clinical findings.</abstract><cop>Londonc</cop><pub>Elsevier Ltd</pub><pmid>11437421</pmid><doi>10.1054/bjom.2000.0580</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0266-4356 |
ispartof | British journal of oral & maxillofacial surgery, 2001-08, Vol.39 (4), p.266-268 |
issn | 0266-4356 1532-1940 |
language | eng |
recordid | cdi_proquest_miscellaneous_70981383 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Animals Biological and medical sciences Biomechanical Phenomena Bone Screws Dental Stress Analysis Dentistry Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics Jaw Fixation Techniques - instrumentation Mandible - surgery Maxillofacial surgery. Dental surgery. Orthodontics Medical sciences Osteotomy - instrumentation Osteotomy - methods Sheep Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases |
title | Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: a study in sheep mandibles |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T14%3A13%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20the%20angle%20of%20the%20screw%20on%20the%20stability%20of%20the%20mandibular%20sagittal%20split%20ramus%20osteotomy:%20a%20study%20in%20sheep%20mandibles&rft.jtitle=British%20journal%20of%20oral%20&%20maxillofacial%20surgery&rft.au=Uckan,%20S.&rft.date=2001-08-01&rft.volume=39&rft.issue=4&rft.spage=266&rft.epage=268&rft.pages=266-268&rft.issn=0266-4356&rft.eissn=1532-1940&rft.coden=BJOSEY&rft_id=info:doi/10.1054/bjom.2000.0580&rft_dat=%3Cproquest_cross%3E70981383%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70981383&rft_id=info:pmid/11437421&rft_els_id=S0266435600905801&rfr_iscdi=true |