Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides

Fused-silica capillary columns of 200 μm inner diameter were packed with micropellicular, octadecylated, 2.3 μm poly(styrene–divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2000-02, Vol.870 (1), p.413-424
Hauptverfasser: Huber, Christian G, Krajete, Alexander
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 424
container_issue 1
container_start_page 413
container_title Journal of Chromatography A
container_volume 870
creator Huber, Christian G
Krajete, Alexander
description Fused-silica capillary columns of 200 μm inner diameter were packed with micropellicular, octadecylated, 2.3 μm poly(styrene–divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50°C with gradients of 3–13% acetonitrile in 50 m M triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanol
doi_str_mv 10.1016/S0021-9673(99)00953-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70976263</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S002196739900953X</els_id><sourcerecordid>70976263</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-8bb511405bae0a2ed8e07f225e254e77ccb17d92e0d0caa6668080bd7f6fb0643</originalsourceid><addsrcrecordid>eNqFkMtq3DAUhrVoSdIkj9DgRSnNwumRPJZGq1JCc4FAFmkgOyFLR2MVe-RIdmE2pe_QN-yTRHNJ2l1WBw7ffy4fIe8pnFGg_PMdAKOl5KL6JOUpgKyr8uENOXhp75N3Kf0AoAIE2yP7NBcGUhyQX3ct6rEtOv84eVugc2jGVPhlYfTgu07HVdH6RVsOGF2IvV4afIZNG0Ovx7CIemhXf3__wS6HY0hD1Kui1ykVadh0ehzznOCK0PlFWE6mwzB6i-mIvHW6S3i8q4fk_uLb9_Or8ub28vr8601pKgljOW-amtIZ1I1G0AztHEE4xmpk9QyFMKahwkqGYMFozTmfwxwaKxx3DfBZdUg-bucOMTxOmEbV-2Qw_7fEMCUlsgzOeJXBegua_EeK6NQQfZ8tKApqLVttZKu1VSWl2shWDzl3slswNT3a_1Jb0xn4sAN0MrpzMZv06R9XMajk-tAvWwyzjZ8eo0rGY5ZufcwqlQ3-lUueAGaqow8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70976263</pqid></control><display><type>article</type><title>Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Huber, Christian G ; Krajete, Alexander</creator><creatorcontrib>Huber, Christian G ; Krajete, Alexander</creatorcontrib><description>Fused-silica capillary columns of 200 μm inner diameter were packed with micropellicular, octadecylated, 2.3 μm poly(styrene–divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50°C with gradients of 3–13% acetonitrile in 50 m M triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanol&lt;methanol&lt;acetonitrile. The incorporation of volatile acids or bases such as triethylamine or hexafluoroisopropanol into the sheath liquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography–electrospray ionization mass spectrometry was applied to the separation and characterization of heterooligonucleotide primers.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/S0021-9673(99)00953-X</identifier><identifier>PMID: 10722097</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical, structural and metabolic biochemistry ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Fundamental and applied biological sciences. Psychology ; General aspects, investigation methods ; Mass Spectrometry ; Nucleic acids ; Oligonucleotides ; Oligonucleotides - analysis ; Spectrophotometry, Ultraviolet</subject><ispartof>Journal of Chromatography A, 2000-02, Vol.870 (1), p.413-424</ispartof><rights>2000 Elsevier Science B.V.</rights><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-8bb511405bae0a2ed8e07f225e254e77ccb17d92e0d0caa6668080bd7f6fb0643</citedby><cites>FETCH-LOGICAL-c390t-8bb511405bae0a2ed8e07f225e254e77ccb17d92e0d0caa6668080bd7f6fb0643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0021-9673(99)00953-X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,3550,23930,23931,25140,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1320394$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10722097$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Huber, Christian G</creatorcontrib><creatorcontrib>Krajete, Alexander</creatorcontrib><title>Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>Fused-silica capillary columns of 200 μm inner diameter were packed with micropellicular, octadecylated, 2.3 μm poly(styrene–divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50°C with gradients of 3–13% acetonitrile in 50 m M triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanol&lt;methanol&lt;acetonitrile. The incorporation of volatile acids or bases such as triethylamine or hexafluoroisopropanol into the sheath liquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography–electrospray ionization mass spectrometry was applied to the separation and characterization of heterooligonucleotide primers.</description><subject>Analytical, structural and metabolic biochemistry</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General aspects, investigation methods</subject><subject>Mass Spectrometry</subject><subject>Nucleic acids</subject><subject>Oligonucleotides</subject><subject>Oligonucleotides - analysis</subject><subject>Spectrophotometry, Ultraviolet</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtq3DAUhrVoSdIkj9DgRSnNwumRPJZGq1JCc4FAFmkgOyFLR2MVe-RIdmE2pe_QN-yTRHNJ2l1WBw7ffy4fIe8pnFGg_PMdAKOl5KL6JOUpgKyr8uENOXhp75N3Kf0AoAIE2yP7NBcGUhyQX3ct6rEtOv84eVugc2jGVPhlYfTgu07HVdH6RVsOGF2IvV4afIZNG0Ovx7CIemhXf3__wS6HY0hD1Kui1ykVadh0ehzznOCK0PlFWE6mwzB6i-mIvHW6S3i8q4fk_uLb9_Or8ub28vr8601pKgljOW-amtIZ1I1G0AztHEE4xmpk9QyFMKahwkqGYMFozTmfwxwaKxx3DfBZdUg-bucOMTxOmEbV-2Qw_7fEMCUlsgzOeJXBegua_EeK6NQQfZ8tKApqLVttZKu1VSWl2shWDzl3slswNT3a_1Jb0xn4sAN0MrpzMZv06R9XMajk-tAvWwyzjZ8eo0rGY5ZufcwqlQ3-lUueAGaqow8</recordid><startdate>20000218</startdate><enddate>20000218</enddate><creator>Huber, Christian G</creator><creator>Krajete, Alexander</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000218</creationdate><title>Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides</title><author>Huber, Christian G ; Krajete, Alexander</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-8bb511405bae0a2ed8e07f225e254e77ccb17d92e0d0caa6668080bd7f6fb0643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Analytical, structural and metabolic biochemistry</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General aspects, investigation methods</topic><topic>Mass Spectrometry</topic><topic>Nucleic acids</topic><topic>Oligonucleotides</topic><topic>Oligonucleotides - analysis</topic><topic>Spectrophotometry, Ultraviolet</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huber, Christian G</creatorcontrib><creatorcontrib>Krajete, Alexander</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huber, Christian G</au><au>Krajete, Alexander</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2000-02-18</date><risdate>2000</risdate><volume>870</volume><issue>1</issue><spage>413</spage><epage>424</epage><pages>413-424</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>Fused-silica capillary columns of 200 μm inner diameter were packed with micropellicular, octadecylated, 2.3 μm poly(styrene–divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50°C with gradients of 3–13% acetonitrile in 50 m M triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanol&lt;methanol&lt;acetonitrile. The incorporation of volatile acids or bases such as triethylamine or hexafluoroisopropanol into the sheath liquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography–electrospray ionization mass spectrometry was applied to the separation and characterization of heterooligonucleotide primers.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>10722097</pmid><doi>10.1016/S0021-9673(99)00953-X</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2000-02, Vol.870 (1), p.413-424
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_70976263
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Analytical, structural and metabolic biochemistry
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Fundamental and applied biological sciences. Psychology
General aspects, investigation methods
Mass Spectrometry
Nucleic acids
Oligonucleotides
Oligonucleotides - analysis
Spectrophotometry, Ultraviolet
title Sheath liquid effects in capillary high-performance liquid chromatography–electrospray mass spectrometry of oligonucleotides
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T04%3A16%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sheath%20liquid%20effects%20in%20capillary%20high-performance%20liquid%20chromatography%E2%80%93electrospray%20mass%20spectrometry%20of%20oligonucleotides&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Huber,%20Christian%20G&rft.date=2000-02-18&rft.volume=870&rft.issue=1&rft.spage=413&rft.epage=424&rft.pages=413-424&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/S0021-9673(99)00953-X&rft_dat=%3Cproquest_cross%3E70976263%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70976263&rft_id=info:pmid/10722097&rft_els_id=S002196739900953X&rfr_iscdi=true