Field-portable, high-speed GC/TOFMS
This work is focused on developing a fast gas chromatograph, time-of-flight mass spectrometer (GC/TOFMS) for man-portable field use. The goal is to achieve a total system solution for meeting performance, size, weight, power, cost, and ruggedness requirements for a laboratory in the field. The core...
Gespeichert in:
Veröffentlicht in: | Journal of the American Society for Mass Spectrometry 2001-06, Vol.12 (6), p.648-655 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 655 |
---|---|
container_issue | 6 |
container_start_page | 648 |
container_title | Journal of the American Society for Mass Spectrometry |
container_volume | 12 |
creator | Syage, Jack A Nies, Brian J Evans, Matthew D Hanold, Karl A |
description | This work is focused on developing a fast gas chromatograph, time-of-flight mass spectrometer (GC/TOFMS) for man-portable field use. The goal is to achieve a total system solution for meeting performance, size, weight, power, cost, and ruggedness requirements for a laboratory in the field. The core technology will also be adaptable to specific applications including real-time point detection for hazardous chemical releases (e.g., chemical weapons), for biological agent signature identification, and for mobile monitoring platforms (e.g., air, ship, truck). Previously we presented results of a feasibility demonstration for a 30-lb field-portable TOFMS system. In this work we present recent progress in integrating a low-power, high-speed GC and show the capability for accurately recording fast GC transients for targeted compound detection using a quadrupole ion trap, time-of-flight instrument (QitTof). |
doi_str_mv | 10.1016/S1044-0305(01)80210-5 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70919676</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1044030501802105</els_id><sourcerecordid>70919676</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-75f9071933a407501ee2a41be8f9427472707c606a16aac9045b59e166cb27883</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMovn-CIiii4Oi9M3lMViLFqqB0UV2HTOaORqadmrSC_97UVhQ3ru5dfOdw-BjbQzhHQHkxROA8gwLECeBpCTlCJlbYJpZKZ4h5sZr-b2SDbcX4CoAKtFpnG4gcEIXcZId9T22dTbowtVVLZwcv_vklixOi-uCmd_E46D8Md9haY9tIu8u7zZ7614-92-x-cHPXu7rPHMdyminRaFCoi8JyUAKQKLccKyobzXPFVa5AOQnSorTWaeCiEppQSlflqiyLbXa86J2E7m1GcWpGPjpqWzumbhZNGo9aKpnAwz_gazcL47TNoBY5L3RRYqLEgnKhizFQYybBj2z4MAhm7tB8OTRzQQbQfDk0IuX2l-2zakT1T2opLQFHS8BGZ9sm2LHz8Vc7LwulEna5wCg5e_cUTHSexo5qH8hNTd35f5Z8AgE6h7g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1952439381</pqid></control><display><type>article</type><title>Field-portable, high-speed GC/TOFMS</title><source>Springer Nature - Complete Springer Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Syage, Jack A ; Nies, Brian J ; Evans, Matthew D ; Hanold, Karl A</creator><creatorcontrib>Syage, Jack A ; Nies, Brian J ; Evans, Matthew D ; Hanold, Karl A</creatorcontrib><description>This work is focused on developing a fast gas chromatograph, time-of-flight mass spectrometer (GC/TOFMS) for man-portable field use. The goal is to achieve a total system solution for meeting performance, size, weight, power, cost, and ruggedness requirements for a laboratory in the field. The core technology will also be adaptable to specific applications including real-time point detection for hazardous chemical releases (e.g., chemical weapons), for biological agent signature identification, and for mobile monitoring platforms (e.g., air, ship, truck). Previously we presented results of a feasibility demonstration for a 30-lb field-portable TOFMS system. In this work we present recent progress in integrating a low-power, high-speed GC and show the capability for accurately recording fast GC transients for targeted compound detection using a quadrupole ion trap, time-of-flight instrument (QitTof).</description><identifier>ISSN: 1044-0305</identifier><identifier>EISSN: 1879-1123</identifier><identifier>DOI: 10.1016/S1044-0305(01)80210-5</identifier><identifier>PMID: 11401156</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Air monitoring ; Analytical chemistry ; Biomonitoring ; Chemical weapons ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Gas chromatographic methods ; Gas chromatography ; High speed ; Instruments, apparatus, components and techniques common to several branches of physics and astronomy ; Ions ; Mass spectrometers and related techniques ; Mass spectrometry ; Physics ; Portability ; Quadrupoles ; Ruggedness ; Spectrometric and optical methods</subject><ispartof>Journal of the American Society for Mass Spectrometry, 2001-06, Vol.12 (6), p.648-655</ispartof><rights>2001 American Society for Mass Spectrometry</rights><rights>2001 INIST-CNRS</rights><rights>American Society for Mass Spectrometry 2001</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-75f9071933a407501ee2a41be8f9427472707c606a16aac9045b59e166cb27883</citedby><cites>FETCH-LOGICAL-c418t-75f9071933a407501ee2a41be8f9427472707c606a16aac9045b59e166cb27883</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23910,23911,25119,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1048377$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11401156$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Syage, Jack A</creatorcontrib><creatorcontrib>Nies, Brian J</creatorcontrib><creatorcontrib>Evans, Matthew D</creatorcontrib><creatorcontrib>Hanold, Karl A</creatorcontrib><title>Field-portable, high-speed GC/TOFMS</title><title>Journal of the American Society for Mass Spectrometry</title><addtitle>J Am Soc Mass Spectrom</addtitle><description>This work is focused on developing a fast gas chromatograph, time-of-flight mass spectrometer (GC/TOFMS) for man-portable field use. The goal is to achieve a total system solution for meeting performance, size, weight, power, cost, and ruggedness requirements for a laboratory in the field. The core technology will also be adaptable to specific applications including real-time point detection for hazardous chemical releases (e.g., chemical weapons), for biological agent signature identification, and for mobile monitoring platforms (e.g., air, ship, truck). Previously we presented results of a feasibility demonstration for a 30-lb field-portable TOFMS system. In this work we present recent progress in integrating a low-power, high-speed GC and show the capability for accurately recording fast GC transients for targeted compound detection using a quadrupole ion trap, time-of-flight instrument (QitTof).</description><subject>Air monitoring</subject><subject>Analytical chemistry</subject><subject>Biomonitoring</subject><subject>Chemical weapons</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Gas chromatographic methods</subject><subject>Gas chromatography</subject><subject>High speed</subject><subject>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</subject><subject>Ions</subject><subject>Mass spectrometers and related techniques</subject><subject>Mass spectrometry</subject><subject>Physics</subject><subject>Portability</subject><subject>Quadrupoles</subject><subject>Ruggedness</subject><subject>Spectrometric and optical methods</subject><issn>1044-0305</issn><issn>1879-1123</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNqFkEtLAzEUhYMovn-CIiii4Oi9M3lMViLFqqB0UV2HTOaORqadmrSC_97UVhQ3ru5dfOdw-BjbQzhHQHkxROA8gwLECeBpCTlCJlbYJpZKZ4h5sZr-b2SDbcX4CoAKtFpnG4gcEIXcZId9T22dTbowtVVLZwcv_vklixOi-uCmd_E46D8Md9haY9tIu8u7zZ7614-92-x-cHPXu7rPHMdyminRaFCoi8JyUAKQKLccKyobzXPFVa5AOQnSorTWaeCiEppQSlflqiyLbXa86J2E7m1GcWpGPjpqWzumbhZNGo9aKpnAwz_gazcL47TNoBY5L3RRYqLEgnKhizFQYybBj2z4MAhm7tB8OTRzQQbQfDk0IuX2l-2zakT1T2opLQFHS8BGZ9sm2LHz8Vc7LwulEna5wCg5e_cUTHSexo5qH8hNTd35f5Z8AgE6h7g</recordid><startdate>20010601</startdate><enddate>20010601</enddate><creator>Syage, Jack A</creator><creator>Nies, Brian J</creator><creator>Evans, Matthew D</creator><creator>Hanold, Karl A</creator><general>Elsevier Inc</general><general>Elsevier Science</general><general>Springer Nature B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>MBDVC</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope></search><sort><creationdate>20010601</creationdate><title>Field-portable, high-speed GC/TOFMS</title><author>Syage, Jack A ; Nies, Brian J ; Evans, Matthew D ; Hanold, Karl A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-75f9071933a407501ee2a41be8f9427472707c606a16aac9045b59e166cb27883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Air monitoring</topic><topic>Analytical chemistry</topic><topic>Biomonitoring</topic><topic>Chemical weapons</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Gas chromatographic methods</topic><topic>Gas chromatography</topic><topic>High speed</topic><topic>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</topic><topic>Ions</topic><topic>Mass spectrometers and related techniques</topic><topic>Mass spectrometry</topic><topic>Physics</topic><topic>Portability</topic><topic>Quadrupoles</topic><topic>Ruggedness</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Syage, Jack A</creatorcontrib><creatorcontrib>Nies, Brian J</creatorcontrib><creatorcontrib>Evans, Matthew D</creatorcontrib><creatorcontrib>Hanold, Karl A</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Research Library (Corporate)</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society for Mass Spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Syage, Jack A</au><au>Nies, Brian J</au><au>Evans, Matthew D</au><au>Hanold, Karl A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Field-portable, high-speed GC/TOFMS</atitle><jtitle>Journal of the American Society for Mass Spectrometry</jtitle><addtitle>J Am Soc Mass Spectrom</addtitle><date>2001-06-01</date><risdate>2001</risdate><volume>12</volume><issue>6</issue><spage>648</spage><epage>655</epage><pages>648-655</pages><issn>1044-0305</issn><eissn>1879-1123</eissn><abstract>This work is focused on developing a fast gas chromatograph, time-of-flight mass spectrometer (GC/TOFMS) for man-portable field use. The goal is to achieve a total system solution for meeting performance, size, weight, power, cost, and ruggedness requirements for a laboratory in the field. The core technology will also be adaptable to specific applications including real-time point detection for hazardous chemical releases (e.g., chemical weapons), for biological agent signature identification, and for mobile monitoring platforms (e.g., air, ship, truck). Previously we presented results of a feasibility demonstration for a 30-lb field-portable TOFMS system. In this work we present recent progress in integrating a low-power, high-speed GC and show the capability for accurately recording fast GC transients for targeted compound detection using a quadrupole ion trap, time-of-flight instrument (QitTof).</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>11401156</pmid><doi>10.1016/S1044-0305(01)80210-5</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1044-0305 |
ispartof | Journal of the American Society for Mass Spectrometry, 2001-06, Vol.12 (6), p.648-655 |
issn | 1044-0305 1879-1123 |
language | eng |
recordid | cdi_proquest_miscellaneous_70919676 |
source | Springer Nature - Complete Springer Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | Air monitoring Analytical chemistry Biomonitoring Chemical weapons Chemistry Chromatographic methods and physical methods associated with chromatography Exact sciences and technology Gas chromatographic methods Gas chromatography High speed Instruments, apparatus, components and techniques common to several branches of physics and astronomy Ions Mass spectrometers and related techniques Mass spectrometry Physics Portability Quadrupoles Ruggedness Spectrometric and optical methods |
title | Field-portable, high-speed GC/TOFMS |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T14%3A14%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Field-portable,%20high-speed%20GC/TOFMS&rft.jtitle=Journal%20of%20the%20American%20Society%20for%20Mass%20Spectrometry&rft.au=Syage,%20Jack%20A&rft.date=2001-06-01&rft.volume=12&rft.issue=6&rft.spage=648&rft.epage=655&rft.pages=648-655&rft.issn=1044-0305&rft.eissn=1879-1123&rft_id=info:doi/10.1016/S1044-0305(01)80210-5&rft_dat=%3Cproquest_cross%3E70919676%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1952439381&rft_id=info:pmid/11401156&rft_els_id=S1044030501802105&rfr_iscdi=true |