A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues
The aim of this study was to evaluate the effect of different functional appliances on the soft tissues as assessed by cephalometry and optical surface scanning. Forty‐two patients were randomly allocated to Bass, Twin Block (TB), and Twin Block + Headgear (TB + Hg) groups. Lateral cephalograms and...
Gespeichert in:
Veröffentlicht in: | European journal of orthodontics 2001-04, Vol.23 (2), p.115-126 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 126 |
---|---|
container_issue | 2 |
container_start_page | 115 |
container_title | European journal of orthodontics |
container_volume | 23 |
creator | McDonagh, S. Moss, J. P. Goodwin, P. Lee, R. T. |
description | The aim of this study was to evaluate the effect of different functional appliances on the soft tissues as assessed by cephalometry and optical surface scanning. Forty‐two patients were randomly allocated to Bass, Twin Block (TB), and Twin Block + Headgear (TB + Hg) groups. Lateral cephalograms and optical surface scans were recorded before and after the 10‐month study period. ANOVA was used to test the cephalometric variables for differences at the 5 per cent level. The optical surface scanning and cephalometric results were consistent in the sagittal dimension. In the vertical dimension, however, the optical surface scans consistently recorded a greater increase compared with cephalometric values. No differences were detected with regard to cephalometric values at the 5 per cent level. However, the Bass appliance produced greater forward positioning of soft tissue pogonion as assessed by optical surface scanning. |
doi_str_mv | 10.1093/ejo/23.2.115 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70919473</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>373539201</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-648c9763d3253de288926692db8b3c4472d621e33380bea6dee50cac802aa63e3</originalsourceid><addsrcrecordid>eNpdkc9rFTEQx4Mo9lm9eZbgwVP3Ncnsj-RYqrWFWpEqiJeQl521-9xN1p1s0Yt_u2nfQ6GnYZgPn2Hmy9hLKdZSGDjGbTxWsFZrKatHbCXLWhRKSfGYrYQsZVGBbg7YM6KtEAJ02TxlB1KC0VVpVuzPCZ_mSBP61N8ij1PqvRs4LXPnPHLyLoQ-fOcutNzjdOOGOGKae88dERKNGBKPHU83yLHrsuau65aQfTFkk5umoXfBI_EY7jGKXeKpJ1qQnrMnnRsIX-zrIfty9u7z6Xlx-fH9xenJZeHBiFTUpfamqaEFVUGLSmuj6tqodqM34MuyUW2tJAKAFht0dYtYCe-8Fsq5GhAO2ZudNx_7M-9NduzJ4zC4gHEh2wgjTdlABl8_ALdxmfMhZJUwQujGiAwd7SCfX0czdnaa-9HNv60U9i4Um0OxCqyyOZSMv9o7l82I7X94n0IGih3QU8Jf_-Zu_mHrBprKnn_9Zj99uD670m-vbQl_Aaz0mLs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>209008790</pqid></control><display><type>article</type><title>A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>McDonagh, S. ; Moss, J. P. ; Goodwin, P. ; Lee, R. T.</creator><creatorcontrib>McDonagh, S. ; Moss, J. P. ; Goodwin, P. ; Lee, R. T.</creatorcontrib><description>The aim of this study was to evaluate the effect of different functional appliances on the soft tissues as assessed by cephalometry and optical surface scanning. Forty‐two patients were randomly allocated to Bass, Twin Block (TB), and Twin Block + Headgear (TB + Hg) groups. Lateral cephalograms and optical surface scans were recorded before and after the 10‐month study period. ANOVA was used to test the cephalometric variables for differences at the 5 per cent level. The optical surface scanning and cephalometric results were consistent in the sagittal dimension. In the vertical dimension, however, the optical surface scans consistently recorded a greater increase compared with cephalometric values. No differences were detected with regard to cephalometric values at the 5 per cent level. However, the Bass appliance produced greater forward positioning of soft tissue pogonion as assessed by optical surface scanning.</description><identifier>ISSN: 0141-5387</identifier><identifier>EISSN: 1460-2210</identifier><identifier>DOI: 10.1093/ejo/23.2.115</identifier><identifier>PMID: 11398549</identifier><identifier>CODEN: EJOODK</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Analysis of Variance ; Cephalometry ; Child ; Dentistry ; Extraoral Traction Appliances ; Face - anatomy & histology ; Female ; Humans ; Imaging, Three-Dimensional - methods ; Male ; Malocclusion, Angle Class II - therapy ; Orthodontic Appliance Design ; Orthodontic Appliances, Functional ; Orthodontics, Corrective - instrumentation ; Pattern Recognition, Automated ; Prospective Studies ; Statistics, Nonparametric ; Treatment Outcome ; Vertical Dimension</subject><ispartof>European journal of orthodontics, 2001-04, Vol.23 (2), p.115-126</ispartof><rights>Copyright Oxford University Press(England) Apr 1, 2001</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-648c9763d3253de288926692db8b3c4472d621e33380bea6dee50cac802aa63e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11398549$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>McDonagh, S.</creatorcontrib><creatorcontrib>Moss, J. P.</creatorcontrib><creatorcontrib>Goodwin, P.</creatorcontrib><creatorcontrib>Lee, R. T.</creatorcontrib><title>A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues</title><title>European journal of orthodontics</title><addtitle>Eur J Orthod</addtitle><description>The aim of this study was to evaluate the effect of different functional appliances on the soft tissues as assessed by cephalometry and optical surface scanning. Forty‐two patients were randomly allocated to Bass, Twin Block (TB), and Twin Block + Headgear (TB + Hg) groups. Lateral cephalograms and optical surface scans were recorded before and after the 10‐month study period. ANOVA was used to test the cephalometric variables for differences at the 5 per cent level. The optical surface scanning and cephalometric results were consistent in the sagittal dimension. In the vertical dimension, however, the optical surface scans consistently recorded a greater increase compared with cephalometric values. No differences were detected with regard to cephalometric values at the 5 per cent level. However, the Bass appliance produced greater forward positioning of soft tissue pogonion as assessed by optical surface scanning.</description><subject>Analysis of Variance</subject><subject>Cephalometry</subject><subject>Child</subject><subject>Dentistry</subject><subject>Extraoral Traction Appliances</subject><subject>Face - anatomy & histology</subject><subject>Female</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional - methods</subject><subject>Male</subject><subject>Malocclusion, Angle Class II - therapy</subject><subject>Orthodontic Appliance Design</subject><subject>Orthodontic Appliances, Functional</subject><subject>Orthodontics, Corrective - instrumentation</subject><subject>Pattern Recognition, Automated</subject><subject>Prospective Studies</subject><subject>Statistics, Nonparametric</subject><subject>Treatment Outcome</subject><subject>Vertical Dimension</subject><issn>0141-5387</issn><issn>1460-2210</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkc9rFTEQx4Mo9lm9eZbgwVP3Ncnsj-RYqrWFWpEqiJeQl521-9xN1p1s0Yt_u2nfQ6GnYZgPn2Hmy9hLKdZSGDjGbTxWsFZrKatHbCXLWhRKSfGYrYQsZVGBbg7YM6KtEAJ02TxlB1KC0VVpVuzPCZ_mSBP61N8ij1PqvRs4LXPnPHLyLoQ-fOcutNzjdOOGOGKae88dERKNGBKPHU83yLHrsuau65aQfTFkk5umoXfBI_EY7jGKXeKpJ1qQnrMnnRsIX-zrIfty9u7z6Xlx-fH9xenJZeHBiFTUpfamqaEFVUGLSmuj6tqodqM34MuyUW2tJAKAFht0dYtYCe-8Fsq5GhAO2ZudNx_7M-9NduzJ4zC4gHEh2wgjTdlABl8_ALdxmfMhZJUwQujGiAwd7SCfX0czdnaa-9HNv60U9i4Um0OxCqyyOZSMv9o7l82I7X94n0IGih3QU8Jf_-Zu_mHrBprKnn_9Zj99uD670m-vbQl_Aaz0mLs</recordid><startdate>20010401</startdate><enddate>20010401</enddate><creator>McDonagh, S.</creator><creator>Moss, J. P.</creator><creator>Goodwin, P.</creator><creator>Lee, R. T.</creator><general>Oxford University Press</general><general>Oxford Publishing Limited (England)</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>20010401</creationdate><title>A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues</title><author>McDonagh, S. ; Moss, J. P. ; Goodwin, P. ; Lee, R. T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-648c9763d3253de288926692db8b3c4472d621e33380bea6dee50cac802aa63e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Analysis of Variance</topic><topic>Cephalometry</topic><topic>Child</topic><topic>Dentistry</topic><topic>Extraoral Traction Appliances</topic><topic>Face - anatomy & histology</topic><topic>Female</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional - methods</topic><topic>Male</topic><topic>Malocclusion, Angle Class II - therapy</topic><topic>Orthodontic Appliance Design</topic><topic>Orthodontic Appliances, Functional</topic><topic>Orthodontics, Corrective - instrumentation</topic><topic>Pattern Recognition, Automated</topic><topic>Prospective Studies</topic><topic>Statistics, Nonparametric</topic><topic>Treatment Outcome</topic><topic>Vertical Dimension</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>McDonagh, S.</creatorcontrib><creatorcontrib>Moss, J. P.</creatorcontrib><creatorcontrib>Goodwin, P.</creatorcontrib><creatorcontrib>Lee, R. T.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of orthodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>McDonagh, S.</au><au>Moss, J. P.</au><au>Goodwin, P.</au><au>Lee, R. T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues</atitle><jtitle>European journal of orthodontics</jtitle><addtitle>Eur J Orthod</addtitle><date>2001-04-01</date><risdate>2001</risdate><volume>23</volume><issue>2</issue><spage>115</spage><epage>126</epage><pages>115-126</pages><issn>0141-5387</issn><eissn>1460-2210</eissn><coden>EJOODK</coden><abstract>The aim of this study was to evaluate the effect of different functional appliances on the soft tissues as assessed by cephalometry and optical surface scanning. Forty‐two patients were randomly allocated to Bass, Twin Block (TB), and Twin Block + Headgear (TB + Hg) groups. Lateral cephalograms and optical surface scans were recorded before and after the 10‐month study period. ANOVA was used to test the cephalometric variables for differences at the 5 per cent level. The optical surface scanning and cephalometric results were consistent in the sagittal dimension. In the vertical dimension, however, the optical surface scans consistently recorded a greater increase compared with cephalometric values. No differences were detected with regard to cephalometric values at the 5 per cent level. However, the Bass appliance produced greater forward positioning of soft tissue pogonion as assessed by optical surface scanning.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>11398549</pmid><doi>10.1093/ejo/23.2.115</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0141-5387 |
ispartof | European journal of orthodontics, 2001-04, Vol.23 (2), p.115-126 |
issn | 0141-5387 1460-2210 |
language | eng |
recordid | cdi_proquest_miscellaneous_70919473 |
source | MEDLINE; Oxford University Press Journals All Titles (1996-Current); EZB-FREE-00999 freely available EZB journals |
subjects | Analysis of Variance Cephalometry Child Dentistry Extraoral Traction Appliances Face - anatomy & histology Female Humans Imaging, Three-Dimensional - methods Male Malocclusion, Angle Class II - therapy Orthodontic Appliance Design Orthodontic Appliances, Functional Orthodontics, Corrective - instrumentation Pattern Recognition, Automated Prospective Studies Statistics, Nonparametric Treatment Outcome Vertical Dimension |
title | A prospective optical surface scanning and cephalometric assessment of the effect of functional appliances on the soft tissues |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T05%3A24%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20prospective%20optical%20surface%20scanning%20and%20cephalometric%20assessment%20of%20the%20effect%20of%20functional%20appliances%20on%20the%20soft%20tissues&rft.jtitle=European%20journal%20of%20orthodontics&rft.au=McDonagh,%20S.&rft.date=2001-04-01&rft.volume=23&rft.issue=2&rft.spage=115&rft.epage=126&rft.pages=115-126&rft.issn=0141-5387&rft.eissn=1460-2210&rft.coden=EJOODK&rft_id=info:doi/10.1093/ejo/23.2.115&rft_dat=%3Cproquest_cross%3E373539201%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=209008790&rft_id=info:pmid/11398549&rfr_iscdi=true |