Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection

Conductivity detection is applied to ion‐exchange capillary electrochromatography (IE‐CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex‐agglomerate anion‐exch...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrophoresis 2001-05, Vol.22 (7), p.1273-1281
Hauptverfasser: Hilder, Emily F., Zemann, Andreas J., Macka, Miroslav, Haddad, Paul R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1281
container_issue 7
container_start_page 1273
container_title Electrophoresis
container_volume 22
creator Hilder, Emily F.
Zemann, Andreas J.
Macka, Miroslav
Haddad, Paul R.
description Conductivity detection is applied to ion‐exchange capillary electrochromatography (IE‐CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex‐agglomerate anion‐exchanger (Dionex AS9‐SC). A systematic approach was used to determine suitable eluants for IE‐CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p‐toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p‐toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4–25 μg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5–50 mM p‐toluenesulfonate) than was the case with indirect UV detection (2.5–10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p‐toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion‐exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).
doi_str_mv 10.1002/1522-2683(200105)22:7<1273::AID-ELPS1273>3.0.CO;2-U
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70884720</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70884720</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4023-daec751ae39d836dbe08b8cb6e0c791639b31fb916656013508e8589d54e7f313</originalsourceid><addsrcrecordid>eNqVUV1v0zAUtRCIlcFfQHlC8JBybSex0yGkUsaYVFFga9nbleO4qyEfxU7Z-u9xlFKeeODJ9-P4HN1zCDmjMKYA7DVNGYtZJvlLBkAhfcXYRLyhTPDJZHr5Pj6ff77qu7d8DOPZ4ozFywdkdPz1kIyACh6D5OkJeeL9dwBI8iR5TE4o5SLPEzki9bSxbRObe71Rza2JtNraqlJuH5nK6M61euPaWnXtrVPbzT66s90msk1pXdhGy1WkmjI6dLptOqW7ynjf1-VOd_aX7fZRabqwDzpPyaO1qrx5dnhPyfLD-fXsYzxfXFzOpvNYJ8B4XCqjRUqV4XkpeVYWBmQhdZEZ0CKnGc8LTtdFqLI0A8pTkEamMi_TxIg1p_yUvBh4t679uTO-w9p6bcJhjWl3HgVImQgGAXg1ALVrvXdmjVtn63A-UsA-Bez9xN5PHFLA0ArsfUcMKeCfFJAj4GyBDJeB9flBflfUpvzLebA9AG4GwJ2tzP5_NP8heZwF6nigtr4z90dq5X5gJrhI8dunC8zffWGrr9c3uOK_AXcAsvQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70884720</pqid></control><display><type>article</type><title>Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Hilder, Emily F. ; Zemann, Andreas J. ; Macka, Miroslav ; Haddad, Paul R.</creator><creatorcontrib>Hilder, Emily F. ; Zemann, Andreas J. ; Macka, Miroslav ; Haddad, Paul R.</creatorcontrib><description>Conductivity detection is applied to ion‐exchange capillary electrochromatography (IE‐CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex‐agglomerate anion‐exchanger (Dionex AS9‐SC). A systematic approach was used to determine suitable eluants for IE‐CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p‐toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p‐toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4–25 μg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5–50 mM p‐toluenesulfonate) than was the case with indirect UV detection (2.5–10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p‐toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion‐exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).</description><identifier>ISSN: 0173-0835</identifier><identifier>EISSN: 1522-2683</identifier><identifier>DOI: 10.1002/1522-2683(200105)22:7&lt;1273::AID-ELPS1273&gt;3.0.CO;2-U</identifier><identifier>PMID: 11379948</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Anion exchange ; Capillary electrochromatography ; Capillary electrochromatography, contactless conductivity detection ; Chromatography, Ion Exchange ; contactless conductivity detection ; Electrophoresis, Capillary ; Indirect UV detection ; Polymer stationary phase ; Ultraviolet Rays</subject><ispartof>Electrophoresis, 2001-05, Vol.22 (7), p.1273-1281</ispartof><rights>Copyright © 2001 WILEY‐VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c4023-daec751ae39d836dbe08b8cb6e0c791639b31fb916656013508e8589d54e7f313</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2F1522-2683%28200105%2922%3A7%3C1273%3A%3AAID-ELPS1273%3E3.0.CO%3B2-U$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2F1522-2683%28200105%2922%3A7%3C1273%3A%3AAID-ELPS1273%3E3.0.CO%3B2-U$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1416,27922,27923,45572,45573</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11379948$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hilder, Emily F.</creatorcontrib><creatorcontrib>Zemann, Andreas J.</creatorcontrib><creatorcontrib>Macka, Miroslav</creatorcontrib><creatorcontrib>Haddad, Paul R.</creatorcontrib><title>Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection</title><title>Electrophoresis</title><addtitle>ELECTROPHORESIS</addtitle><description>Conductivity detection is applied to ion‐exchange capillary electrochromatography (IE‐CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex‐agglomerate anion‐exchanger (Dionex AS9‐SC). A systematic approach was used to determine suitable eluants for IE‐CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p‐toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p‐toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4–25 μg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5–50 mM p‐toluenesulfonate) than was the case with indirect UV detection (2.5–10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p‐toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion‐exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).</description><subject>Anion exchange</subject><subject>Capillary electrochromatography</subject><subject>Capillary electrochromatography, contactless conductivity detection</subject><subject>Chromatography, Ion Exchange</subject><subject>contactless conductivity detection</subject><subject>Electrophoresis, Capillary</subject><subject>Indirect UV detection</subject><subject>Polymer stationary phase</subject><subject>Ultraviolet Rays</subject><issn>0173-0835</issn><issn>1522-2683</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqVUV1v0zAUtRCIlcFfQHlC8JBybSex0yGkUsaYVFFga9nbleO4qyEfxU7Z-u9xlFKeeODJ9-P4HN1zCDmjMKYA7DVNGYtZJvlLBkAhfcXYRLyhTPDJZHr5Pj6ff77qu7d8DOPZ4ozFywdkdPz1kIyACh6D5OkJeeL9dwBI8iR5TE4o5SLPEzki9bSxbRObe71Rza2JtNraqlJuH5nK6M61euPaWnXtrVPbzT66s90msk1pXdhGy1WkmjI6dLptOqW7ynjf1-VOd_aX7fZRabqwDzpPyaO1qrx5dnhPyfLD-fXsYzxfXFzOpvNYJ8B4XCqjRUqV4XkpeVYWBmQhdZEZ0CKnGc8LTtdFqLI0A8pTkEamMi_TxIg1p_yUvBh4t679uTO-w9p6bcJhjWl3HgVImQgGAXg1ALVrvXdmjVtn63A-UsA-Bez9xN5PHFLA0ArsfUcMKeCfFJAj4GyBDJeB9flBflfUpvzLebA9AG4GwJ2tzP5_NP8heZwF6nigtr4z90dq5X5gJrhI8dunC8zffWGrr9c3uOK_AXcAsvQ</recordid><startdate>200105</startdate><enddate>200105</enddate><creator>Hilder, Emily F.</creator><creator>Zemann, Andreas J.</creator><creator>Macka, Miroslav</creator><creator>Haddad, Paul R.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200105</creationdate><title>Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection</title><author>Hilder, Emily F. ; Zemann, Andreas J. ; Macka, Miroslav ; Haddad, Paul R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4023-daec751ae39d836dbe08b8cb6e0c791639b31fb916656013508e8589d54e7f313</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Anion exchange</topic><topic>Capillary electrochromatography</topic><topic>Capillary electrochromatography, contactless conductivity detection</topic><topic>Chromatography, Ion Exchange</topic><topic>contactless conductivity detection</topic><topic>Electrophoresis, Capillary</topic><topic>Indirect UV detection</topic><topic>Polymer stationary phase</topic><topic>Ultraviolet Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hilder, Emily F.</creatorcontrib><creatorcontrib>Zemann, Andreas J.</creatorcontrib><creatorcontrib>Macka, Miroslav</creatorcontrib><creatorcontrib>Haddad, Paul R.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Electrophoresis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hilder, Emily F.</au><au>Zemann, Andreas J.</au><au>Macka, Miroslav</au><au>Haddad, Paul R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection</atitle><jtitle>Electrophoresis</jtitle><addtitle>ELECTROPHORESIS</addtitle><date>2001-05</date><risdate>2001</risdate><volume>22</volume><issue>7</issue><spage>1273</spage><epage>1281</epage><pages>1273-1281</pages><issn>0173-0835</issn><eissn>1522-2683</eissn><abstract>Conductivity detection is applied to ion‐exchange capillary electrochromatography (IE‐CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex‐agglomerate anion‐exchanger (Dionex AS9‐SC). A systematic approach was used to determine suitable eluants for IE‐CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p‐toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p‐toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4–25 μg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5–50 mM p‐toluenesulfonate) than was the case with indirect UV detection (2.5–10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p‐toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion‐exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>11379948</pmid><doi>10.1002/1522-2683(200105)22:7&lt;1273::AID-ELPS1273&gt;3.0.CO;2-U</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0173-0835
ispartof Electrophoresis, 2001-05, Vol.22 (7), p.1273-1281
issn 0173-0835
1522-2683
language eng
recordid cdi_proquest_miscellaneous_70884720
source MEDLINE; Wiley Online Library All Journals
subjects Anion exchange
Capillary electrochromatography
Capillary electrochromatography, contactless conductivity detection
Chromatography, Ion Exchange
contactless conductivity detection
Electrophoresis, Capillary
Indirect UV detection
Polymer stationary phase
Ultraviolet Rays
title Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T10%3A50%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anion-exchange%20capillary%20electrochromatography%20with%20indirect%20UV%20and%20direct%20contactless%20conductivity%20detection&rft.jtitle=Electrophoresis&rft.au=Hilder,%20Emily%20F.&rft.date=2001-05&rft.volume=22&rft.issue=7&rft.spage=1273&rft.epage=1281&rft.pages=1273-1281&rft.issn=0173-0835&rft.eissn=1522-2683&rft_id=info:doi/10.1002/1522-2683(200105)22:7%3C1273::AID-ELPS1273%3E3.0.CO;2-U&rft_dat=%3Cproquest_cross%3E70884720%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70884720&rft_id=info:pmid/11379948&rfr_iscdi=true