Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells
A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer cat...
Gespeichert in:
Veröffentlicht in: | Ultrasound in medicine & biology 2001-03, Vol.27 (3), p.409-417 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 417 |
---|---|
container_issue | 3 |
container_start_page | 409 |
container_title | Ultrasound in medicine & biology |
container_volume | 27 |
creator | LUPOTTI, Fermin A CESPEDES, E. Ignacio VAN DER STEEN, Antonius F. W |
description | A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer catheter. The decorrelation characteristics during transverse blood flow using the IVUS array catheter were investigated using computer modeling. Before this, blood was simulated as a collection of randomly located point scatterers and, by moving this scattering medium transversely across the acoustical beam, blood flow was simulated. This paper presents a more realistic scattering media by simulating aggregates of red blood cells (RBCs) as strings of point scatterers. Three configurations of aggregates of RBCs were simulated. First, aggregates of RBCs were strings with different lengths and parallel to the catheter axis. Second, the strings were with a fixed length and angles of plus or minus 45 degrees with respect to the catheter axis. Third, the strings were with different lengths and random angles ranging from -45 degrees to + 45 degrees. The decorrelation characteristics for these configurations of aggregates of RBCs were investigated and compared with point scatterers. For the aggregates of RBCs parallel to the catheter axis, the decorrelation rate became slower when the aggregate length was increased. RBC aggregations with fixed and random lengths and angles resulted in a decorrelation rate that approaches the decorrelation pattern from point scatterers. Results suggests that the presence of aggregates of RBCs will probably not affect the measurements of transverse blood flow using a decorrelation-based method and an IVUS array catheter. |
doi_str_mv | 10.1016/S0301-5629(00)00347-1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70862129</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70862129</sourcerecordid><originalsourceid>FETCH-LOGICAL-c335t-9ac9176d48bad64b22bcf44c26778c4d339be58313db8ce187bf511bba1a82e23</originalsourceid><addsrcrecordid>eNpFkdFqFDEUhoNY7Lb6CEpAkHoxNSeZSSa9k1q1UPBCBe_CSSbZjmQnNZmt9A362GZ3h3oVDnznP-H7CXkN7BwYyA_fmWDQdJLrM8beMyZa1cAzsoJe6YZr-PWcrJ6QY3JSym_GmJJCvSDHAEJq4GpFHj95l3L2EecxTdTdYkY3-zyWeXSFpkDnjFO597l4amNKAw0x_aUY07SmONFxqsA9FreNmCnmjA_U4Xzrawi9oFcheDfvg3C9zn59uFPH7Icl0PkYy0tyFDAW_2p5T8nPz1c_Lr82N9--XF9-vGmcEN3caHQalBza3uIgW8u5daFtHZdK9a4dhNDWd70AMdje-WrDhg7AWgTsuefilLw75N7l9Gfry2w2Y9n9ACeftsUo1ksOXFewO4Aup1KyD-YujxvMDwaY2VVg9hWYnV_DmNlXYKDuvVkObO3GD_-3FucVeLsA1RrGUP26sTxxWjIBvfgH74GRQw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70862129</pqid></control><display><type>article</type><title>Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>LUPOTTI, Fermin A ; CESPEDES, E. Ignacio ; VAN DER STEEN, Antonius F. W</creator><creatorcontrib>LUPOTTI, Fermin A ; CESPEDES, E. Ignacio ; VAN DER STEEN, Antonius F. W</creatorcontrib><description>A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer catheter. The decorrelation characteristics during transverse blood flow using the IVUS array catheter were investigated using computer modeling. Before this, blood was simulated as a collection of randomly located point scatterers and, by moving this scattering medium transversely across the acoustical beam, blood flow was simulated. This paper presents a more realistic scattering media by simulating aggregates of red blood cells (RBCs) as strings of point scatterers. Three configurations of aggregates of RBCs were simulated. First, aggregates of RBCs were strings with different lengths and parallel to the catheter axis. Second, the strings were with a fixed length and angles of plus or minus 45 degrees with respect to the catheter axis. Third, the strings were with different lengths and random angles ranging from -45 degrees to + 45 degrees. The decorrelation characteristics for these configurations of aggregates of RBCs were investigated and compared with point scatterers. For the aggregates of RBCs parallel to the catheter axis, the decorrelation rate became slower when the aggregate length was increased. RBC aggregations with fixed and random lengths and angles resulted in a decorrelation rate that approaches the decorrelation pattern from point scatterers. Results suggests that the presence of aggregates of RBCs will probably not affect the measurements of transverse blood flow using a decorrelation-based method and an IVUS array catheter.</description><identifier>ISSN: 0301-5629</identifier><identifier>EISSN: 1879-291X</identifier><identifier>DOI: 10.1016/S0301-5629(00)00347-1</identifier><identifier>PMID: 11369127</identifier><identifier>CODEN: USMBA3</identifier><language>eng</language><publisher>Amsterdam: Elsevier</publisher><subject>Biological and medical sciences ; Blood Flow Velocity ; Cardiovascular system ; Catheterization ; Computer Simulation ; Erythrocyte Aggregation ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Ultrasonic investigative techniques ; Ultrasonography, Interventional - instrumentation</subject><ispartof>Ultrasound in medicine & biology, 2001-03, Vol.27 (3), p.409-417</ispartof><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c335t-9ac9176d48bad64b22bcf44c26778c4d339be58313db8ce187bf511bba1a82e23</citedby><cites>FETCH-LOGICAL-c335t-9ac9176d48bad64b22bcf44c26778c4d339be58313db8ce187bf511bba1a82e23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=960318$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11369127$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>LUPOTTI, Fermin A</creatorcontrib><creatorcontrib>CESPEDES, E. Ignacio</creatorcontrib><creatorcontrib>VAN DER STEEN, Antonius F. W</creatorcontrib><title>Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells</title><title>Ultrasound in medicine & biology</title><addtitle>Ultrasound Med Biol</addtitle><description>A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer catheter. The decorrelation characteristics during transverse blood flow using the IVUS array catheter were investigated using computer modeling. Before this, blood was simulated as a collection of randomly located point scatterers and, by moving this scattering medium transversely across the acoustical beam, blood flow was simulated. This paper presents a more realistic scattering media by simulating aggregates of red blood cells (RBCs) as strings of point scatterers. Three configurations of aggregates of RBCs were simulated. First, aggregates of RBCs were strings with different lengths and parallel to the catheter axis. Second, the strings were with a fixed length and angles of plus or minus 45 degrees with respect to the catheter axis. Third, the strings were with different lengths and random angles ranging from -45 degrees to + 45 degrees. The decorrelation characteristics for these configurations of aggregates of RBCs were investigated and compared with point scatterers. For the aggregates of RBCs parallel to the catheter axis, the decorrelation rate became slower when the aggregate length was increased. RBC aggregations with fixed and random lengths and angles resulted in a decorrelation rate that approaches the decorrelation pattern from point scatterers. Results suggests that the presence of aggregates of RBCs will probably not affect the measurements of transverse blood flow using a decorrelation-based method and an IVUS array catheter.</description><subject>Biological and medical sciences</subject><subject>Blood Flow Velocity</subject><subject>Cardiovascular system</subject><subject>Catheterization</subject><subject>Computer Simulation</subject><subject>Erythrocyte Aggregation</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Ultrasonic investigative techniques</subject><subject>Ultrasonography, Interventional - instrumentation</subject><issn>0301-5629</issn><issn>1879-291X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkdFqFDEUhoNY7Lb6CEpAkHoxNSeZSSa9k1q1UPBCBe_CSSbZjmQnNZmt9A362GZ3h3oVDnznP-H7CXkN7BwYyA_fmWDQdJLrM8beMyZa1cAzsoJe6YZr-PWcrJ6QY3JSym_GmJJCvSDHAEJq4GpFHj95l3L2EecxTdTdYkY3-zyWeXSFpkDnjFO597l4amNKAw0x_aUY07SmONFxqsA9FreNmCnmjA_U4Xzrawi9oFcheDfvg3C9zn59uFPH7Icl0PkYy0tyFDAW_2p5T8nPz1c_Lr82N9--XF9-vGmcEN3caHQalBza3uIgW8u5daFtHZdK9a4dhNDWd70AMdje-WrDhg7AWgTsuefilLw75N7l9Gfry2w2Y9n9ACeftsUo1ksOXFewO4Aup1KyD-YujxvMDwaY2VVg9hWYnV_DmNlXYKDuvVkObO3GD_-3FucVeLsA1RrGUP26sTxxWjIBvfgH74GRQw</recordid><startdate>20010301</startdate><enddate>20010301</enddate><creator>LUPOTTI, Fermin A</creator><creator>CESPEDES, E. Ignacio</creator><creator>VAN DER STEEN, Antonius F. W</creator><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010301</creationdate><title>Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells</title><author>LUPOTTI, Fermin A ; CESPEDES, E. Ignacio ; VAN DER STEEN, Antonius F. W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c335t-9ac9176d48bad64b22bcf44c26778c4d339be58313db8ce187bf511bba1a82e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Biological and medical sciences</topic><topic>Blood Flow Velocity</topic><topic>Cardiovascular system</topic><topic>Catheterization</topic><topic>Computer Simulation</topic><topic>Erythrocyte Aggregation</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Ultrasonic investigative techniques</topic><topic>Ultrasonography, Interventional - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LUPOTTI, Fermin A</creatorcontrib><creatorcontrib>CESPEDES, E. Ignacio</creatorcontrib><creatorcontrib>VAN DER STEEN, Antonius F. W</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Ultrasound in medicine & biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LUPOTTI, Fermin A</au><au>CESPEDES, E. Ignacio</au><au>VAN DER STEEN, Antonius F. W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells</atitle><jtitle>Ultrasound in medicine & biology</jtitle><addtitle>Ultrasound Med Biol</addtitle><date>2001-03-01</date><risdate>2001</risdate><volume>27</volume><issue>3</issue><spage>409</spage><epage>417</epage><pages>409-417</pages><issn>0301-5629</issn><eissn>1879-291X</eissn><coden>USMBA3</coden><abstract>A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer catheter. The decorrelation characteristics during transverse blood flow using the IVUS array catheter were investigated using computer modeling. Before this, blood was simulated as a collection of randomly located point scatterers and, by moving this scattering medium transversely across the acoustical beam, blood flow was simulated. This paper presents a more realistic scattering media by simulating aggregates of red blood cells (RBCs) as strings of point scatterers. Three configurations of aggregates of RBCs were simulated. First, aggregates of RBCs were strings with different lengths and parallel to the catheter axis. Second, the strings were with a fixed length and angles of plus or minus 45 degrees with respect to the catheter axis. Third, the strings were with different lengths and random angles ranging from -45 degrees to + 45 degrees. The decorrelation characteristics for these configurations of aggregates of RBCs were investigated and compared with point scatterers. For the aggregates of RBCs parallel to the catheter axis, the decorrelation rate became slower when the aggregate length was increased. RBC aggregations with fixed and random lengths and angles resulted in a decorrelation rate that approaches the decorrelation pattern from point scatterers. Results suggests that the presence of aggregates of RBCs will probably not affect the measurements of transverse blood flow using a decorrelation-based method and an IVUS array catheter.</abstract><cop>Amsterdam</cop><pub>Elsevier</pub><pmid>11369127</pmid><doi>10.1016/S0301-5629(00)00347-1</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0301-5629 |
ispartof | Ultrasound in medicine & biology, 2001-03, Vol.27 (3), p.409-417 |
issn | 0301-5629 1879-291X |
language | eng |
recordid | cdi_proquest_miscellaneous_70862129 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Biological and medical sciences Blood Flow Velocity Cardiovascular system Catheterization Computer Simulation Erythrocyte Aggregation Humans Investigative techniques, diagnostic techniques (general aspects) Medical sciences Ultrasonic investigative techniques Ultrasonography, Interventional - instrumentation |
title | Decorrelation characteristics of transverse blood flow along an intravascular array catheter : Effects of aggregation of red blood cells |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T19%3A15%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Decorrelation%20characteristics%20of%20transverse%20blood%20flow%20along%20an%20intravascular%20array%20catheter%20:%20Effects%20of%20aggregation%20of%20red%20blood%20cells&rft.jtitle=Ultrasound%20in%20medicine%20&%20biology&rft.au=LUPOTTI,%20Fermin%20A&rft.date=2001-03-01&rft.volume=27&rft.issue=3&rft.spage=409&rft.epage=417&rft.pages=409-417&rft.issn=0301-5629&rft.eissn=1879-291X&rft.coden=USMBA3&rft_id=info:doi/10.1016/S0301-5629(00)00347-1&rft_dat=%3Cproquest_cross%3E70862129%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70862129&rft_id=info:pmid/11369127&rfr_iscdi=true |