Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes

The retention of ionogenic bases in liquid chromatography is strongly dependent upon the pH of the mobile phase. Chromatographic behavior of a series of substituted aniline and pyridine basic compounds has been studied on C 18 bonded silica using acetonitrile–water (10:90) as the eluent with differe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2001-04, Vol.913 (1), p.173-187
Hauptverfasser: LoBrutto, R, Jones, A, Kazakevich, Y.V, McNair, H.M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 187
container_issue 1
container_start_page 173
container_title Journal of Chromatography A
container_volume 913
creator LoBrutto, R
Jones, A
Kazakevich, Y.V
McNair, H.M
description The retention of ionogenic bases in liquid chromatography is strongly dependent upon the pH of the mobile phase. Chromatographic behavior of a series of substituted aniline and pyridine basic compounds has been studied on C 18 bonded silica using acetonitrile–water (10:90) as the eluent with different pHs and at various concentrations of the acidic modifier counter anions. The effect of different acidic modifiers on solute retention over a pH range from 1.3 to 8.6 was studied. Ionized basic compounds showed increased retention with a decrease of the mobile phase pH. This increase in retention was attributed to the interaction with counter anions of the acidic modifiers. The increase in retention is dependent on the nature of the counter anion and its concentration in the mobile phase. It was shown that altering the concentration of counter anion of the acidic modifier allows the optimization of the selectivity between basic compounds as well as for neutral and acidic compounds.
doi_str_mv 10.1016/S0021-9673(00)01012-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70851877</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967300010128</els_id><sourcerecordid>70851877</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-f7a870d0cb636afb29724cc13639bdfd61e4a8866f007b935e00ba3e03ba6a543</originalsourceid><addsrcrecordid>eNqFkcFu1DAQhnMA0VJ4BJAlJASHwDje2M4JoapQpEocgLM1sceNURKndlJp3x5vd9UeOY00-uaf0TdV9YbDJw5cfv4F0PC6k0p8APgIpdfU-ll1_tg-q17m_BeAK1DNi-qMc9G2mvPzKl15T3Zl0bN1IEbjRvPKlmuGs2NogwuWTdEFHyhlFmY2hNuhXij5mCacLbEx3G3BMTukOOEabxMuw54lWktQiPMhucdcYnDGcb9SflU99zhmen2qF9Wfb1e_L6_rm5_ff1x-vamt0N1ae4VagQPbSyHR902nmp21XEjR9c47yWmHWkvpAVTfiZYAehQEokeJ7U5cVO-PuUuKdxvl1UwhWxpHnClu2SjQLddKFbA9gjbFnBN5s6QwYdobDuYg2DwINgeTBsA8CDa6zL09Ldj6idzT1MluAd6dAMwWR5-KsJAfuU42UstCfTlSVGTcF88m20BFrQupvMa4GP5zyD-h1pp9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70851877</pqid></control><display><type>article</type><title>Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>LoBrutto, R ; Jones, A ; Kazakevich, Y.V ; McNair, H.M</creator><creatorcontrib>LoBrutto, R ; Jones, A ; Kazakevich, Y.V ; McNair, H.M</creatorcontrib><description>The retention of ionogenic bases in liquid chromatography is strongly dependent upon the pH of the mobile phase. Chromatographic behavior of a series of substituted aniline and pyridine basic compounds has been studied on C 18 bonded silica using acetonitrile–water (10:90) as the eluent with different pHs and at various concentrations of the acidic modifier counter anions. The effect of different acidic modifiers on solute retention over a pH range from 1.3 to 8.6 was studied. Ionized basic compounds showed increased retention with a decrease of the mobile phase pH. This increase in retention was attributed to the interaction with counter anions of the acidic modifiers. The increase in retention is dependent on the nature of the counter anion and its concentration in the mobile phase. It was shown that altering the concentration of counter anion of the acidic modifier allows the optimization of the selectivity between basic compounds as well as for neutral and acidic compounds.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/S0021-9673(00)01012-8</identifier><identifier>PMID: 11355811</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Anilines ; Buffers ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography, High Pressure Liquid - methods ; Exact sciences and technology ; Hydrogen-Ion Concentration ; Other chromatographic methods ; Perchlorates - chemistry ; Phosphates - chemistry ; Phosphoric Acids - chemistry ; Pyridines ; Trichloroacetic Acid - chemistry</subject><ispartof>Journal of Chromatography A, 2001-04, Vol.913 (1), p.173-187</ispartof><rights>2001 Elsevier Science B.V.</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-f7a870d0cb636afb29724cc13639bdfd61e4a8866f007b935e00ba3e03ba6a543</citedby><cites>FETCH-LOGICAL-c389t-f7a870d0cb636afb29724cc13639bdfd61e4a8866f007b935e00ba3e03ba6a543</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0021-9673(00)01012-8$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,3550,23930,23931,25140,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=962686$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11355811$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>LoBrutto, R</creatorcontrib><creatorcontrib>Jones, A</creatorcontrib><creatorcontrib>Kazakevich, Y.V</creatorcontrib><creatorcontrib>McNair, H.M</creatorcontrib><title>Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>The retention of ionogenic bases in liquid chromatography is strongly dependent upon the pH of the mobile phase. Chromatographic behavior of a series of substituted aniline and pyridine basic compounds has been studied on C 18 bonded silica using acetonitrile–water (10:90) as the eluent with different pHs and at various concentrations of the acidic modifier counter anions. The effect of different acidic modifiers on solute retention over a pH range from 1.3 to 8.6 was studied. Ionized basic compounds showed increased retention with a decrease of the mobile phase pH. This increase in retention was attributed to the interaction with counter anions of the acidic modifiers. The increase in retention is dependent on the nature of the counter anion and its concentration in the mobile phase. It was shown that altering the concentration of counter anion of the acidic modifier allows the optimization of the selectivity between basic compounds as well as for neutral and acidic compounds.</description><subject>Analytical chemistry</subject><subject>Anilines</subject><subject>Buffers</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Exact sciences and technology</subject><subject>Hydrogen-Ion Concentration</subject><subject>Other chromatographic methods</subject><subject>Perchlorates - chemistry</subject><subject>Phosphates - chemistry</subject><subject>Phosphoric Acids - chemistry</subject><subject>Pyridines</subject><subject>Trichloroacetic Acid - chemistry</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcFu1DAQhnMA0VJ4BJAlJASHwDje2M4JoapQpEocgLM1sceNURKndlJp3x5vd9UeOY00-uaf0TdV9YbDJw5cfv4F0PC6k0p8APgIpdfU-ll1_tg-q17m_BeAK1DNi-qMc9G2mvPzKl15T3Zl0bN1IEbjRvPKlmuGs2NogwuWTdEFHyhlFmY2hNuhXij5mCacLbEx3G3BMTukOOEabxMuw54lWktQiPMhucdcYnDGcb9SflU99zhmen2qF9Wfb1e_L6_rm5_ff1x-vamt0N1ae4VagQPbSyHR902nmp21XEjR9c47yWmHWkvpAVTfiZYAehQEokeJ7U5cVO-PuUuKdxvl1UwhWxpHnClu2SjQLddKFbA9gjbFnBN5s6QwYdobDuYg2DwINgeTBsA8CDa6zL09Ldj6idzT1MluAd6dAMwWR5-KsJAfuU42UstCfTlSVGTcF88m20BFrQupvMa4GP5zyD-h1pp9</recordid><startdate>20010413</startdate><enddate>20010413</enddate><creator>LoBrutto, R</creator><creator>Jones, A</creator><creator>Kazakevich, Y.V</creator><creator>McNair, H.M</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010413</creationdate><title>Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes</title><author>LoBrutto, R ; Jones, A ; Kazakevich, Y.V ; McNair, H.M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-f7a870d0cb636afb29724cc13639bdfd61e4a8866f007b935e00ba3e03ba6a543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Analytical chemistry</topic><topic>Anilines</topic><topic>Buffers</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Exact sciences and technology</topic><topic>Hydrogen-Ion Concentration</topic><topic>Other chromatographic methods</topic><topic>Perchlorates - chemistry</topic><topic>Phosphates - chemistry</topic><topic>Phosphoric Acids - chemistry</topic><topic>Pyridines</topic><topic>Trichloroacetic Acid - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LoBrutto, R</creatorcontrib><creatorcontrib>Jones, A</creatorcontrib><creatorcontrib>Kazakevich, Y.V</creatorcontrib><creatorcontrib>McNair, H.M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LoBrutto, R</au><au>Jones, A</au><au>Kazakevich, Y.V</au><au>McNair, H.M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2001-04-13</date><risdate>2001</risdate><volume>913</volume><issue>1</issue><spage>173</spage><epage>187</epage><pages>173-187</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>The retention of ionogenic bases in liquid chromatography is strongly dependent upon the pH of the mobile phase. Chromatographic behavior of a series of substituted aniline and pyridine basic compounds has been studied on C 18 bonded silica using acetonitrile–water (10:90) as the eluent with different pHs and at various concentrations of the acidic modifier counter anions. The effect of different acidic modifiers on solute retention over a pH range from 1.3 to 8.6 was studied. Ionized basic compounds showed increased retention with a decrease of the mobile phase pH. This increase in retention was attributed to the interaction with counter anions of the acidic modifiers. The increase in retention is dependent on the nature of the counter anion and its concentration in the mobile phase. It was shown that altering the concentration of counter anion of the acidic modifier allows the optimization of the selectivity between basic compounds as well as for neutral and acidic compounds.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>11355811</pmid><doi>10.1016/S0021-9673(00)01012-8</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2001-04, Vol.913 (1), p.173-187
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_70851877
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Analytical chemistry
Anilines
Buffers
Chemistry
Chromatographic methods and physical methods associated with chromatography
Chromatography, High Pressure Liquid - methods
Exact sciences and technology
Hydrogen-Ion Concentration
Other chromatographic methods
Perchlorates - chemistry
Phosphates - chemistry
Phosphoric Acids - chemistry
Pyridines
Trichloroacetic Acid - chemistry
title Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T10%3A44%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20the%20eluent%20pH%20and%20acidic%20modifiers%20in%20high-performance%20liquid%20chromatography%20retention%20of%20basic%20analytes&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=LoBrutto,%20R&rft.date=2001-04-13&rft.volume=913&rft.issue=1&rft.spage=173&rft.epage=187&rft.pages=173-187&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/S0021-9673(00)01012-8&rft_dat=%3Cproquest_cross%3E70851877%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70851877&rft_id=info:pmid/11355811&rft_els_id=S0021967300010128&rfr_iscdi=true