Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma

PURPOSEThe digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma. METHODSFifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, O...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of glaucoma 1999-10, Vol.8 (5), p.297-301
Hauptverfasser: Yogesan, Kanagasingam, Constable, Ian J, Barry, Chris J, Eikelboom, Robert H, Morgan, William, Tay-Kearney, Mei-Ling, Jitskaia, Ludmila
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 301
container_issue 5
container_start_page 297
container_title Journal of glaucoma
container_volume 8
creator Yogesan, Kanagasingam
Constable, Ian J
Barry, Chris J
Eikelboom, Robert H
Morgan, William
Tay-Kearney, Mei-Ling
Jitskaia, Ludmila
description PURPOSEThe digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma. METHODSFifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, Oberkochen, Germany) and a portable Nidek NM-100 (Nidek, Tokyo, Japan) fundus camera. Digital images from the portable fundus camera were digitized, compressed and stored in a Fujix DF-10M (Fuji, Tokyo, Japan) digitizer. Lossy compressed digital images and photographs from the Zeiss camera were presented separately in random order to three ophthalmologists for estimation of vertical cuprdisk ratios (VCDR) and to evaluate image quality as good, acceptable, or unacceptable for screening glaucoma. Gold standard VCDRs were measured from monoscopic photographic slides obtained using the Zeiss camera by a fourth ophthalmologist. RESULTSMeasurement of agreement (Kappa values) between estimated VCDR of digital images and photographs by the three ophthalmologists were 0.52,0.38, and 0.50 respectively. Agreement between gold standard and estimated VCDR from photographs were 0.87, 0.45, and 0.84 respectively (specificity between 79% and 97%, sensitivity between 70% and 95%). Kappa values obtained between gold standard and estimated VCDR from digital images were 0.52, 0.49, and 0.49, respectively (specificity between 68% and 79%, sensitivity between 67% and 87%. CONCLUSIONModerate to good agreement indicates that the digital images from the portable fundus camera may be suitable for optic disk assessment in the current configuration. This easy to use Nidek hand-held camera could be a viable instrument for teleophthalmology if a better digitizing system is incorporated to improve the quality of the images.
doi_str_mv 10.1097/00061198-199910000-00004
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70844536</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70844536</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3564-3154bc6dbe4ba81a561184526c89e5d9476803673383703fd715c882da6c96a63</originalsourceid><addsrcrecordid>eNp1kctO5TAMhiM0iPsroKzYFZImTZPl6Aw3CQkWILEiclOXlkmbQ9KCeHt6OIDYsPFF_m3LnwmhnB1zZsoTxpji3OiMG2P4nLFsZeQG2eGFUJnU_P7PHLOizJjOzTbZTemJsZzlOd8i23MhNybXO-Th9AX8BGMXBhoaCvQmxBEqj_RsGuop0QX0GIE2IdK7hLQb6NgivUWPYdmOLfg--PDYOfqvg8chpC6t5px7mFzoYZ9sNuATHnz6PXJ3dnq7uMiurs8vF3-vMicKJTPBC1k5VVcoK9Acivk6LYtcOW2wqI0slWZClUJoUTLR1CUvnNZ5DcoZBUrskaP13GUMzxOm0fZdcug9DBimZEumpZzJzEK9FroYUorY2GXseohvljO7Ymu_2NpvtvaD7dx6-LljqnqsfzSuYc4CuRa8Bj9iTP_99IrRtgh-bO1vPxPvrIWC6w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70844536</pqid></control><display><type>article</type><title>Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Yogesan, Kanagasingam ; Constable, Ian J ; Barry, Chris J ; Eikelboom, Robert H ; Morgan, William ; Tay-Kearney, Mei-Ling ; Jitskaia, Ludmila</creator><creatorcontrib>Yogesan, Kanagasingam ; Constable, Ian J ; Barry, Chris J ; Eikelboom, Robert H ; Morgan, William ; Tay-Kearney, Mei-Ling ; Jitskaia, Ludmila</creatorcontrib><description>PURPOSEThe digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma. METHODSFifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, Oberkochen, Germany) and a portable Nidek NM-100 (Nidek, Tokyo, Japan) fundus camera. Digital images from the portable fundus camera were digitized, compressed and stored in a Fujix DF-10M (Fuji, Tokyo, Japan) digitizer. Lossy compressed digital images and photographs from the Zeiss camera were presented separately in random order to three ophthalmologists for estimation of vertical cuprdisk ratios (VCDR) and to evaluate image quality as good, acceptable, or unacceptable for screening glaucoma. Gold standard VCDRs were measured from monoscopic photographic slides obtained using the Zeiss camera by a fourth ophthalmologist. RESULTSMeasurement of agreement (Kappa values) between estimated VCDR of digital images and photographs by the three ophthalmologists were 0.52,0.38, and 0.50 respectively. Agreement between gold standard and estimated VCDR from photographs were 0.87, 0.45, and 0.84 respectively (specificity between 79% and 97%, sensitivity between 70% and 95%). Kappa values obtained between gold standard and estimated VCDR from digital images were 0.52, 0.49, and 0.49, respectively (specificity between 68% and 79%, sensitivity between 67% and 87%. CONCLUSIONModerate to good agreement indicates that the digital images from the portable fundus camera may be suitable for optic disk assessment in the current configuration. This easy to use Nidek hand-held camera could be a viable instrument for teleophthalmology if a better digitizing system is incorporated to improve the quality of the images.</description><identifier>ISSN: 1057-0829</identifier><identifier>EISSN: 1536-481X</identifier><identifier>DOI: 10.1097/00061198-199910000-00004</identifier><identifier>PMID: 10529928</identifier><language>eng</language><publisher>United States: Lippincott Williams &amp; Wilkins, Inc</publisher><subject>Diagnostic Techniques, Ophthalmological - instrumentation ; Fundus Oculi ; Glaucoma - diagnosis ; Humans ; Image Processing, Computer-Assisted - methods ; Optic Disk - pathology ; Photography - instrumentation ; Sensitivity and Specificity ; Telemedicine - methods</subject><ispartof>Journal of glaucoma, 1999-10, Vol.8 (5), p.297-301</ispartof><rights>1999 Lippincott Williams &amp; Wilkins, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3564-3154bc6dbe4ba81a561184526c89e5d9476803673383703fd715c882da6c96a63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10529928$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yogesan, Kanagasingam</creatorcontrib><creatorcontrib>Constable, Ian J</creatorcontrib><creatorcontrib>Barry, Chris J</creatorcontrib><creatorcontrib>Eikelboom, Robert H</creatorcontrib><creatorcontrib>Morgan, William</creatorcontrib><creatorcontrib>Tay-Kearney, Mei-Ling</creatorcontrib><creatorcontrib>Jitskaia, Ludmila</creatorcontrib><title>Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma</title><title>Journal of glaucoma</title><addtitle>J Glaucoma</addtitle><description>PURPOSEThe digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma. METHODSFifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, Oberkochen, Germany) and a portable Nidek NM-100 (Nidek, Tokyo, Japan) fundus camera. Digital images from the portable fundus camera were digitized, compressed and stored in a Fujix DF-10M (Fuji, Tokyo, Japan) digitizer. Lossy compressed digital images and photographs from the Zeiss camera were presented separately in random order to three ophthalmologists for estimation of vertical cuprdisk ratios (VCDR) and to evaluate image quality as good, acceptable, or unacceptable for screening glaucoma. Gold standard VCDRs were measured from monoscopic photographic slides obtained using the Zeiss camera by a fourth ophthalmologist. RESULTSMeasurement of agreement (Kappa values) between estimated VCDR of digital images and photographs by the three ophthalmologists were 0.52,0.38, and 0.50 respectively. Agreement between gold standard and estimated VCDR from photographs were 0.87, 0.45, and 0.84 respectively (specificity between 79% and 97%, sensitivity between 70% and 95%). Kappa values obtained between gold standard and estimated VCDR from digital images were 0.52, 0.49, and 0.49, respectively (specificity between 68% and 79%, sensitivity between 67% and 87%. CONCLUSIONModerate to good agreement indicates that the digital images from the portable fundus camera may be suitable for optic disk assessment in the current configuration. This easy to use Nidek hand-held camera could be a viable instrument for teleophthalmology if a better digitizing system is incorporated to improve the quality of the images.</description><subject>Diagnostic Techniques, Ophthalmological - instrumentation</subject><subject>Fundus Oculi</subject><subject>Glaucoma - diagnosis</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Optic Disk - pathology</subject><subject>Photography - instrumentation</subject><subject>Sensitivity and Specificity</subject><subject>Telemedicine - methods</subject><issn>1057-0829</issn><issn>1536-481X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kctO5TAMhiM0iPsroKzYFZImTZPl6Aw3CQkWILEiclOXlkmbQ9KCeHt6OIDYsPFF_m3LnwmhnB1zZsoTxpji3OiMG2P4nLFsZeQG2eGFUJnU_P7PHLOizJjOzTbZTemJsZzlOd8i23MhNybXO-Th9AX8BGMXBhoaCvQmxBEqj_RsGuop0QX0GIE2IdK7hLQb6NgivUWPYdmOLfg--PDYOfqvg8chpC6t5px7mFzoYZ9sNuATHnz6PXJ3dnq7uMiurs8vF3-vMicKJTPBC1k5VVcoK9Acivk6LYtcOW2wqI0slWZClUJoUTLR1CUvnNZ5DcoZBUrskaP13GUMzxOm0fZdcug9DBimZEumpZzJzEK9FroYUorY2GXseohvljO7Ymu_2NpvtvaD7dx6-LljqnqsfzSuYc4CuRa8Bj9iTP_99IrRtgh-bO1vPxPvrIWC6w</recordid><startdate>199910</startdate><enddate>199910</enddate><creator>Yogesan, Kanagasingam</creator><creator>Constable, Ian J</creator><creator>Barry, Chris J</creator><creator>Eikelboom, Robert H</creator><creator>Morgan, William</creator><creator>Tay-Kearney, Mei-Ling</creator><creator>Jitskaia, Ludmila</creator><general>Lippincott Williams &amp; Wilkins, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199910</creationdate><title>Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma</title><author>Yogesan, Kanagasingam ; Constable, Ian J ; Barry, Chris J ; Eikelboom, Robert H ; Morgan, William ; Tay-Kearney, Mei-Ling ; Jitskaia, Ludmila</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3564-3154bc6dbe4ba81a561184526c89e5d9476803673383703fd715c882da6c96a63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Diagnostic Techniques, Ophthalmological - instrumentation</topic><topic>Fundus Oculi</topic><topic>Glaucoma - diagnosis</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Optic Disk - pathology</topic><topic>Photography - instrumentation</topic><topic>Sensitivity and Specificity</topic><topic>Telemedicine - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yogesan, Kanagasingam</creatorcontrib><creatorcontrib>Constable, Ian J</creatorcontrib><creatorcontrib>Barry, Chris J</creatorcontrib><creatorcontrib>Eikelboom, Robert H</creatorcontrib><creatorcontrib>Morgan, William</creatorcontrib><creatorcontrib>Tay-Kearney, Mei-Ling</creatorcontrib><creatorcontrib>Jitskaia, Ludmila</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of glaucoma</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yogesan, Kanagasingam</au><au>Constable, Ian J</au><au>Barry, Chris J</au><au>Eikelboom, Robert H</au><au>Morgan, William</au><au>Tay-Kearney, Mei-Ling</au><au>Jitskaia, Ludmila</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma</atitle><jtitle>Journal of glaucoma</jtitle><addtitle>J Glaucoma</addtitle><date>1999-10</date><risdate>1999</risdate><volume>8</volume><issue>5</issue><spage>297</spage><epage>301</epage><pages>297-301</pages><issn>1057-0829</issn><eissn>1536-481X</eissn><abstract>PURPOSEThe digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma. METHODSFifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, Oberkochen, Germany) and a portable Nidek NM-100 (Nidek, Tokyo, Japan) fundus camera. Digital images from the portable fundus camera were digitized, compressed and stored in a Fujix DF-10M (Fuji, Tokyo, Japan) digitizer. Lossy compressed digital images and photographs from the Zeiss camera were presented separately in random order to three ophthalmologists for estimation of vertical cuprdisk ratios (VCDR) and to evaluate image quality as good, acceptable, or unacceptable for screening glaucoma. Gold standard VCDRs were measured from monoscopic photographic slides obtained using the Zeiss camera by a fourth ophthalmologist. RESULTSMeasurement of agreement (Kappa values) between estimated VCDR of digital images and photographs by the three ophthalmologists were 0.52,0.38, and 0.50 respectively. Agreement between gold standard and estimated VCDR from photographs were 0.87, 0.45, and 0.84 respectively (specificity between 79% and 97%, sensitivity between 70% and 95%). Kappa values obtained between gold standard and estimated VCDR from digital images were 0.52, 0.49, and 0.49, respectively (specificity between 68% and 79%, sensitivity between 67% and 87%. CONCLUSIONModerate to good agreement indicates that the digital images from the portable fundus camera may be suitable for optic disk assessment in the current configuration. This easy to use Nidek hand-held camera could be a viable instrument for teleophthalmology if a better digitizing system is incorporated to improve the quality of the images.</abstract><cop>United States</cop><pub>Lippincott Williams &amp; Wilkins, Inc</pub><pmid>10529928</pmid><doi>10.1097/00061198-199910000-00004</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1057-0829
ispartof Journal of glaucoma, 1999-10, Vol.8 (5), p.297-301
issn 1057-0829
1536-481X
language eng
recordid cdi_proquest_miscellaneous_70844536
source MEDLINE; Journals@Ovid Complete
subjects Diagnostic Techniques, Ophthalmological - instrumentation
Fundus Oculi
Glaucoma - diagnosis
Humans
Image Processing, Computer-Assisted - methods
Optic Disk - pathology
Photography - instrumentation
Sensitivity and Specificity
Telemedicine - methods
title Evaluation of a Portable Fundus Camera for Use in the Teleophthalmologic Diagnosis of Glaucoma
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T16%3A34%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20Portable%20Fundus%20Camera%20for%20Use%20in%20the%20Teleophthalmologic%20Diagnosis%20of%20Glaucoma&rft.jtitle=Journal%20of%20glaucoma&rft.au=Yogesan,%20Kanagasingam&rft.date=1999-10&rft.volume=8&rft.issue=5&rft.spage=297&rft.epage=301&rft.pages=297-301&rft.issn=1057-0829&rft.eissn=1536-481X&rft_id=info:doi/10.1097/00061198-199910000-00004&rft_dat=%3Cproquest_cross%3E70844536%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70844536&rft_id=info:pmid/10529928&rfr_iscdi=true