Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes

Abstract To date, no published study has examined quantitatively the effect of geometric and dimensional idealization on prediction of the mechanical signals imparted by fluid drag to cell surfaces. We hypothesize that this idealization affects the magnitude and range of imparted forces predicted to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomechanics 2008-01, Vol.41 (8), p.1736-1746
Hauptverfasser: Anderson, Eric J, Knothe Tate, Melissa L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1746
container_issue 8
container_start_page 1736
container_title Journal of biomechanics
container_volume 41
creator Anderson, Eric J
Knothe Tate, Melissa L
description Abstract To date, no published study has examined quantitatively the effect of geometric and dimensional idealization on prediction of the mechanical signals imparted by fluid drag to cell surfaces. We hypothesize that this idealization affects the magnitude and range of imparted forces predicted to occur at a subcellular level. Hence, we used computational fluid dynamics to predict magnitudes and spatial variation of fluid velocity and pressure, as well as shear stress, on the cell surface in two- and three-dimensional models of actual and idealized pericellular canalicular geometries. Furthermore, variation in actual pericellular space dimensions was analyzed statistically based on high-resolution transmitted electron micrographs (TEM). Accounting for the naturally occurring protrusions of the pericellular space delineating lamina limitans resulted in predictions of localized stress spikes on the cell surface, up to five times those predicted using idealized geometries. Predictions accounting for actual pericellular geometries approached those required to trigger cell activity in in vitro models. Furthermore, statistical analysis of TEM-based dimensions showed significant variation in the width of the canalicular space as well as the diameter of the cell process, both of which decrease with increasing distance from the cell body. For the first time to our knowledge, this study shows the influence of physiologic geometry per se on the nano-scale flow regimes in bone, and the profound influence of physiologic geometry on force magnitudes and variations imparted locally to cells through load-induced fluid flow.
doi_str_mv 10.1016/j.jbiomech.2008.02.035
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70758608</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0021929008001073</els_id><sourcerecordid>70758608</sourcerecordid><originalsourceid>FETCH-LOGICAL-c577t-18cf9324d6d98c93c5397d2c0ae8f8e58c6e24cf040cac1ba2cd5c7155bd47c03</originalsourceid><addsrcrecordid>eNqNkk9v1DAQxSMEokvhK1SWkLhlGTtx7FwQqOJPpUocgLPlHU-KlyQOdoK0fCA-Jw67VaVeyiHyIb_3RvPmFcUFhy0H3rzeb_c7HwbC71sBoLcgtlDJR8WGa1WVotLwuNgACF62ooWz4llKewBQtWqfFmdc11oooTfFnytHtve_7ezDyELHJooeqe-X3kbW9Yt3LE0Wid1QHjfHA7OjY84PNKZVEikt_ZyYH5llUwxdWPL__FGcIjmPt8ajHUM5eIwhoe2JpTlLE2XlMNk4k2O7w2mgi_aGrao0U8DDTOl58aSzfaIXp_e8-Pbh_dfLT-X1549Xl--uS5RKzSXX2LWVqF3jWo1thbJqlRMIlnSnSWpsSNTYQQ1oke-sQCdRcSl3rlYI1Xnx6uibN_m5UJrN4NMahx0pLMkoUFI3oB8EeStBKiH_C-TQ8Ay-vAfuwxLHvK3h-bSca_2Pao7UmmOK1Jkp-sHGQ4bM2gyzN7fNMGszDAiT5Vl4cbJfdgO5O9mpChl4ewQo5_vLUzQJPY2YbxgJZ-OCf3jGm3sW2PvR53P_oAOlu31MygLzZe3nWk_QkDNQVfUXXNjmPQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1035118861</pqid></control><display><type>article</type><title>Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><source>ProQuest Central UK/Ireland</source><creator>Anderson, Eric J ; Knothe Tate, Melissa L</creator><creatorcontrib>Anderson, Eric J ; Knothe Tate, Melissa L</creatorcontrib><description>Abstract To date, no published study has examined quantitatively the effect of geometric and dimensional idealization on prediction of the mechanical signals imparted by fluid drag to cell surfaces. We hypothesize that this idealization affects the magnitude and range of imparted forces predicted to occur at a subcellular level. Hence, we used computational fluid dynamics to predict magnitudes and spatial variation of fluid velocity and pressure, as well as shear stress, on the cell surface in two- and three-dimensional models of actual and idealized pericellular canalicular geometries. Furthermore, variation in actual pericellular space dimensions was analyzed statistically based on high-resolution transmitted electron micrographs (TEM). Accounting for the naturally occurring protrusions of the pericellular space delineating lamina limitans resulted in predictions of localized stress spikes on the cell surface, up to five times those predicted using idealized geometries. Predictions accounting for actual pericellular geometries approached those required to trigger cell activity in in vitro models. Furthermore, statistical analysis of TEM-based dimensions showed significant variation in the width of the canalicular space as well as the diameter of the cell process, both of which decrease with increasing distance from the cell body. For the first time to our knowledge, this study shows the influence of physiologic geometry per se on the nano-scale flow regimes in bone, and the profound influence of physiologic geometry on force magnitudes and variations imparted locally to cells through load-induced fluid flow.</description><identifier>ISSN: 0021-9290</identifier><identifier>EISSN: 1873-2380</identifier><identifier>DOI: 10.1016/j.jbiomech.2008.02.035</identifier><identifier>PMID: 18482728</identifier><language>eng</language><publisher>United States: Elsevier Ltd</publisher><subject>Biomechanical Phenomena ; Bone Matrix - physiology ; Cell mechanics ; Computer Simulation ; Extracellular Fluid - physiology ; Mechanical loading ; Mechanotransduction ; Mechanotransduction, Cellular - physiology ; Microfluidics ; Osteocytes ; Osteocytes - physiology ; Osteocytes - ultrastructure ; Physical Medicine and Rehabilitation ; Stress, Mechanical ; Stress/strain</subject><ispartof>Journal of biomechanics, 2008-01, Vol.41 (8), p.1736-1746</ispartof><rights>Elsevier Ltd</rights><rights>2008 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c577t-18cf9324d6d98c93c5397d2c0ae8f8e58c6e24cf040cac1ba2cd5c7155bd47c03</citedby><cites>FETCH-LOGICAL-c577t-18cf9324d6d98c93c5397d2c0ae8f8e58c6e24cf040cac1ba2cd5c7155bd47c03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/1035118861?pq-origsite=primo$$EHTML$$P50$$Gproquest$$H</linktohtml><link.rule.ids>314,780,784,3549,27923,27924,45994,64384,64386,64388,72340</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18482728$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Anderson, Eric J</creatorcontrib><creatorcontrib>Knothe Tate, Melissa L</creatorcontrib><title>Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes</title><title>Journal of biomechanics</title><addtitle>J Biomech</addtitle><description>Abstract To date, no published study has examined quantitatively the effect of geometric and dimensional idealization on prediction of the mechanical signals imparted by fluid drag to cell surfaces. We hypothesize that this idealization affects the magnitude and range of imparted forces predicted to occur at a subcellular level. Hence, we used computational fluid dynamics to predict magnitudes and spatial variation of fluid velocity and pressure, as well as shear stress, on the cell surface in two- and three-dimensional models of actual and idealized pericellular canalicular geometries. Furthermore, variation in actual pericellular space dimensions was analyzed statistically based on high-resolution transmitted electron micrographs (TEM). Accounting for the naturally occurring protrusions of the pericellular space delineating lamina limitans resulted in predictions of localized stress spikes on the cell surface, up to five times those predicted using idealized geometries. Predictions accounting for actual pericellular geometries approached those required to trigger cell activity in in vitro models. Furthermore, statistical analysis of TEM-based dimensions showed significant variation in the width of the canalicular space as well as the diameter of the cell process, both of which decrease with increasing distance from the cell body. For the first time to our knowledge, this study shows the influence of physiologic geometry per se on the nano-scale flow regimes in bone, and the profound influence of physiologic geometry on force magnitudes and variations imparted locally to cells through load-induced fluid flow.</description><subject>Biomechanical Phenomena</subject><subject>Bone Matrix - physiology</subject><subject>Cell mechanics</subject><subject>Computer Simulation</subject><subject>Extracellular Fluid - physiology</subject><subject>Mechanical loading</subject><subject>Mechanotransduction</subject><subject>Mechanotransduction, Cellular - physiology</subject><subject>Microfluidics</subject><subject>Osteocytes</subject><subject>Osteocytes - physiology</subject><subject>Osteocytes - ultrastructure</subject><subject>Physical Medicine and Rehabilitation</subject><subject>Stress, Mechanical</subject><subject>Stress/strain</subject><issn>0021-9290</issn><issn>1873-2380</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNqNkk9v1DAQxSMEokvhK1SWkLhlGTtx7FwQqOJPpUocgLPlHU-KlyQOdoK0fCA-Jw67VaVeyiHyIb_3RvPmFcUFhy0H3rzeb_c7HwbC71sBoLcgtlDJR8WGa1WVotLwuNgACF62ooWz4llKewBQtWqfFmdc11oooTfFnytHtve_7ezDyELHJooeqe-X3kbW9Yt3LE0Wid1QHjfHA7OjY84PNKZVEikt_ZyYH5llUwxdWPL__FGcIjmPt8ajHUM5eIwhoe2JpTlLE2XlMNk4k2O7w2mgi_aGrao0U8DDTOl58aSzfaIXp_e8-Pbh_dfLT-X1549Xl--uS5RKzSXX2LWVqF3jWo1thbJqlRMIlnSnSWpsSNTYQQ1oke-sQCdRcSl3rlYI1Xnx6uibN_m5UJrN4NMahx0pLMkoUFI3oB8EeStBKiH_C-TQ8Ay-vAfuwxLHvK3h-bSca_2Pao7UmmOK1Jkp-sHGQ4bM2gyzN7fNMGszDAiT5Vl4cbJfdgO5O9mpChl4ewQo5_vLUzQJPY2YbxgJZ-OCf3jGm3sW2PvR53P_oAOlu31MygLzZe3nWk_QkDNQVfUXXNjmPQ</recordid><startdate>20080101</startdate><enddate>20080101</enddate><creator>Anderson, Eric J</creator><creator>Knothe Tate, Melissa L</creator><general>Elsevier Ltd</general><general>Elsevier Limited</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QP</scope><scope>7TB</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>M7P</scope><scope>MBDVC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope></search><sort><creationdate>20080101</creationdate><title>Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes</title><author>Anderson, Eric J ; Knothe Tate, Melissa L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c577t-18cf9324d6d98c93c5397d2c0ae8f8e58c6e24cf040cac1ba2cd5c7155bd47c03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Biomechanical Phenomena</topic><topic>Bone Matrix - physiology</topic><topic>Cell mechanics</topic><topic>Computer Simulation</topic><topic>Extracellular Fluid - physiology</topic><topic>Mechanical loading</topic><topic>Mechanotransduction</topic><topic>Mechanotransduction, Cellular - physiology</topic><topic>Microfluidics</topic><topic>Osteocytes</topic><topic>Osteocytes - physiology</topic><topic>Osteocytes - ultrastructure</topic><topic>Physical Medicine and Rehabilitation</topic><topic>Stress, Mechanical</topic><topic>Stress/strain</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Anderson, Eric J</creatorcontrib><creatorcontrib>Knothe Tate, Melissa L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Physical Education Index</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Biological Science Database</collection><collection>Research Library (Corporate)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Anderson, Eric J</au><au>Knothe Tate, Melissa L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes</atitle><jtitle>Journal of biomechanics</jtitle><addtitle>J Biomech</addtitle><date>2008-01-01</date><risdate>2008</risdate><volume>41</volume><issue>8</issue><spage>1736</spage><epage>1746</epage><pages>1736-1746</pages><issn>0021-9290</issn><eissn>1873-2380</eissn><abstract>Abstract To date, no published study has examined quantitatively the effect of geometric and dimensional idealization on prediction of the mechanical signals imparted by fluid drag to cell surfaces. We hypothesize that this idealization affects the magnitude and range of imparted forces predicted to occur at a subcellular level. Hence, we used computational fluid dynamics to predict magnitudes and spatial variation of fluid velocity and pressure, as well as shear stress, on the cell surface in two- and three-dimensional models of actual and idealized pericellular canalicular geometries. Furthermore, variation in actual pericellular space dimensions was analyzed statistically based on high-resolution transmitted electron micrographs (TEM). Accounting for the naturally occurring protrusions of the pericellular space delineating lamina limitans resulted in predictions of localized stress spikes on the cell surface, up to five times those predicted using idealized geometries. Predictions accounting for actual pericellular geometries approached those required to trigger cell activity in in vitro models. Furthermore, statistical analysis of TEM-based dimensions showed significant variation in the width of the canalicular space as well as the diameter of the cell process, both of which decrease with increasing distance from the cell body. For the first time to our knowledge, this study shows the influence of physiologic geometry per se on the nano-scale flow regimes in bone, and the profound influence of physiologic geometry on force magnitudes and variations imparted locally to cells through load-induced fluid flow.</abstract><cop>United States</cop><pub>Elsevier Ltd</pub><pmid>18482728</pmid><doi>10.1016/j.jbiomech.2008.02.035</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9290
ispartof Journal of biomechanics, 2008-01, Vol.41 (8), p.1736-1746
issn 0021-9290
1873-2380
language eng
recordid cdi_proquest_miscellaneous_70758608
source MEDLINE; ScienceDirect Journals (5 years ago - present); ProQuest Central UK/Ireland
subjects Biomechanical Phenomena
Bone Matrix - physiology
Cell mechanics
Computer Simulation
Extracellular Fluid - physiology
Mechanical loading
Mechanotransduction
Mechanotransduction, Cellular - physiology
Microfluidics
Osteocytes
Osteocytes - physiology
Osteocytes - ultrastructure
Physical Medicine and Rehabilitation
Stress, Mechanical
Stress/strain
title Idealization of pericellular fluid space geometry and dimension results in a profound underprediction of nano-microscale stresses imparted by fluid drag on osteocytes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A10%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Idealization%20of%20pericellular%20fluid%20space%20geometry%20and%20dimension%20results%20in%20a%20profound%20underprediction%20of%20nano-microscale%20stresses%20imparted%20by%20fluid%20drag%20on%20osteocytes&rft.jtitle=Journal%20of%20biomechanics&rft.au=Anderson,%20Eric%20J&rft.date=2008-01-01&rft.volume=41&rft.issue=8&rft.spage=1736&rft.epage=1746&rft.pages=1736-1746&rft.issn=0021-9290&rft.eissn=1873-2380&rft_id=info:doi/10.1016/j.jbiomech.2008.02.035&rft_dat=%3Cproquest_cross%3E70758608%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1035118861&rft_id=info:pmid/18482728&rft_els_id=1_s2_0_S0021929008001073&rfr_iscdi=true