A simple method for water discrimination based on an light emitting diode (LED) photometer

This work describes the use of a multi-LED photometer for discrimination of mineral water samples, employing chromogenic reagents and chemometric techniques. Forty-five water samples (including 7 different brands of mineral water and samples of deionised, distilled and tap waters) were analysed in a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2007-07, Vol.596 (1), p.66-72
Hauptverfasser: Fonseca, Alexandre, Raimundo, Ivo M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 72
container_issue 1
container_start_page 66
container_title Analytica chimica acta
container_volume 596
creator Fonseca, Alexandre
Raimundo, Ivo M.
description This work describes the use of a multi-LED photometer for discrimination of mineral water samples, employing chromogenic reagents and chemometric techniques. Forty-five water samples (including 7 different brands of mineral water and samples of deionised, distilled and tap waters) were analysed in a monosegmented flow system, using three different chromogenic reagents (murexide, PAR and eriochrome black T) in a pH 10.0 NH 3/NH 4 + buffer in separate injections. Measurements were performed at 470, 500, 525, 562, 590, 612, 636 and 654 nm. Analyses were carried out using PCA, employing data sets including absorbance values obtained with one, two or all three reagents, which comprise 8, 16 or 24 variables, respectively. The best result was obtained with the data set from murexide and eriochrome black T, providing a clear distinction between 9 groups (distilled and deionised waters were classified in the same group). Based on the loading values, it was possible to select four wavelengths (470, 500, 590 and 654 nm) that provided a similar discrimination. With the use of these four LED, an HCA was performed, providing discrimination between 8 groups at a similarity level of 0.88. A model based on SIMCA allowed correctly classifying 94% of the samples. The discrimination between different groups is due to the metal ion contents in the water samples, mainly calcium and magnesium. Therefore, the use of common complexing reagents, such as murexide and erichrome black T, a multi-LED photometer and chemometric techniques provide an easy and simple method for water discrimination.
doi_str_mv 10.1016/j.aca.2007.05.059
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70700464</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267007009919</els_id><sourcerecordid>70700464</sourcerecordid><originalsourceid>FETCH-LOGICAL-c443t-6bcce4ee4b51255ee3f8de65c4493aea241f9c0cd474ddc58e0b5cd006ae1a5c3</originalsourceid><addsrcrecordid>eNqFkU9rGzEQxUVIqZ20HyCXoEtKclh3tCvtH3IyjtMWDL20l16EVpq1ZXZXjiSn9NtXxgbfEhiYEfrN4zGPkBsGMwas_LqdKa1mOUA1A5GquSBTVldFxoucX5IpABRZXlYwIVchbNMzZ8A_kgmrSlbmnE3JnzkNdtj1SAeMG2do5zz9qyJ6amzQ3g52VNG6kbYqoKFpUCPt7XoTKQ42RjuuE-kM0vvV8umB7jYuuqSF_hP50Kk-4OdTvya_n5e_Ft-z1c9vPxbzVaY5L2JWtlojR-StYLkQiEVXGyxF-m0KhSrZ7BoN2vCKG6NFjdAKbQBKhUwJXVyTL0fdnXcvewxRDsk59r0a0e2DrKAC4CV_F8ybphaigfdB4DVnokkgO4LauxA8dnKXLqb8P8lAHiKSW5kikoeIJIhUh53bk_i-HdCcN06ZJODuBKigVd95NWobzlydHDaFSNzjkcN03FeLXgZtcdRorEcdpXH2DRv_AeCTriU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20484159</pqid></control><display><type>article</type><title>A simple method for water discrimination based on an light emitting diode (LED) photometer</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Fonseca, Alexandre ; Raimundo, Ivo M.</creator><creatorcontrib>Fonseca, Alexandre ; Raimundo, Ivo M.</creatorcontrib><description>This work describes the use of a multi-LED photometer for discrimination of mineral water samples, employing chromogenic reagents and chemometric techniques. Forty-five water samples (including 7 different brands of mineral water and samples of deionised, distilled and tap waters) were analysed in a monosegmented flow system, using three different chromogenic reagents (murexide, PAR and eriochrome black T) in a pH 10.0 NH 3/NH 4 + buffer in separate injections. Measurements were performed at 470, 500, 525, 562, 590, 612, 636 and 654 nm. Analyses were carried out using PCA, employing data sets including absorbance values obtained with one, two or all three reagents, which comprise 8, 16 or 24 variables, respectively. The best result was obtained with the data set from murexide and eriochrome black T, providing a clear distinction between 9 groups (distilled and deionised waters were classified in the same group). Based on the loading values, it was possible to select four wavelengths (470, 500, 590 and 654 nm) that provided a similar discrimination. With the use of these four LED, an HCA was performed, providing discrimination between 8 groups at a similarity level of 0.88. A model based on SIMCA allowed correctly classifying 94% of the samples. The discrimination between different groups is due to the metal ion contents in the water samples, mainly calcium and magnesium. Therefore, the use of common complexing reagents, such as murexide and erichrome black T, a multi-LED photometer and chemometric techniques provide an easy and simple method for water discrimination.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2007.05.059</identifier><identifier>PMID: 17616241</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; Hierarchical cluster analysis ; Light emitting diode (LED) ; Monosegmented flow ; Pattern recognition ; Photometry ; Principal component analysis ; Soft independent modelling of class analogy ; Spectrometric and optical methods ; Water</subject><ispartof>Analytica chimica acta, 2007-07, Vol.596 (1), p.66-72</ispartof><rights>2007 Elsevier B.V.</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c443t-6bcce4ee4b51255ee3f8de65c4493aea241f9c0cd474ddc58e0b5cd006ae1a5c3</citedby><cites>FETCH-LOGICAL-c443t-6bcce4ee4b51255ee3f8de65c4493aea241f9c0cd474ddc58e0b5cd006ae1a5c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.aca.2007.05.059$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18903935$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17616241$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fonseca, Alexandre</creatorcontrib><creatorcontrib>Raimundo, Ivo M.</creatorcontrib><title>A simple method for water discrimination based on an light emitting diode (LED) photometer</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>This work describes the use of a multi-LED photometer for discrimination of mineral water samples, employing chromogenic reagents and chemometric techniques. Forty-five water samples (including 7 different brands of mineral water and samples of deionised, distilled and tap waters) were analysed in a monosegmented flow system, using three different chromogenic reagents (murexide, PAR and eriochrome black T) in a pH 10.0 NH 3/NH 4 + buffer in separate injections. Measurements were performed at 470, 500, 525, 562, 590, 612, 636 and 654 nm. Analyses were carried out using PCA, employing data sets including absorbance values obtained with one, two or all three reagents, which comprise 8, 16 or 24 variables, respectively. The best result was obtained with the data set from murexide and eriochrome black T, providing a clear distinction between 9 groups (distilled and deionised waters were classified in the same group). Based on the loading values, it was possible to select four wavelengths (470, 500, 590 and 654 nm) that provided a similar discrimination. With the use of these four LED, an HCA was performed, providing discrimination between 8 groups at a similarity level of 0.88. A model based on SIMCA allowed correctly classifying 94% of the samples. The discrimination between different groups is due to the metal ion contents in the water samples, mainly calcium and magnesium. Therefore, the use of common complexing reagents, such as murexide and erichrome black T, a multi-LED photometer and chemometric techniques provide an easy and simple method for water discrimination.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Hierarchical cluster analysis</subject><subject>Light emitting diode (LED)</subject><subject>Monosegmented flow</subject><subject>Pattern recognition</subject><subject>Photometry</subject><subject>Principal component analysis</subject><subject>Soft independent modelling of class analogy</subject><subject>Spectrometric and optical methods</subject><subject>Water</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkU9rGzEQxUVIqZ20HyCXoEtKclh3tCvtH3IyjtMWDL20l16EVpq1ZXZXjiSn9NtXxgbfEhiYEfrN4zGPkBsGMwas_LqdKa1mOUA1A5GquSBTVldFxoucX5IpABRZXlYwIVchbNMzZ8A_kgmrSlbmnE3JnzkNdtj1SAeMG2do5zz9qyJ6amzQ3g52VNG6kbYqoKFpUCPt7XoTKQ42RjuuE-kM0vvV8umB7jYuuqSF_hP50Kk-4OdTvya_n5e_Ft-z1c9vPxbzVaY5L2JWtlojR-StYLkQiEVXGyxF-m0KhSrZ7BoN2vCKG6NFjdAKbQBKhUwJXVyTL0fdnXcvewxRDsk59r0a0e2DrKAC4CV_F8ybphaigfdB4DVnokkgO4LauxA8dnKXLqb8P8lAHiKSW5kikoeIJIhUh53bk_i-HdCcN06ZJODuBKigVd95NWobzlydHDaFSNzjkcN03FeLXgZtcdRorEcdpXH2DRv_AeCTriU</recordid><startdate>20070716</startdate><enddate>20070716</enddate><creator>Fonseca, Alexandre</creator><creator>Raimundo, Ivo M.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7TV</scope><scope>7UA</scope><scope>C1K</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20070716</creationdate><title>A simple method for water discrimination based on an light emitting diode (LED) photometer</title><author>Fonseca, Alexandre ; Raimundo, Ivo M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c443t-6bcce4ee4b51255ee3f8de65c4493aea241f9c0cd474ddc58e0b5cd006ae1a5c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Hierarchical cluster analysis</topic><topic>Light emitting diode (LED)</topic><topic>Monosegmented flow</topic><topic>Pattern recognition</topic><topic>Photometry</topic><topic>Principal component analysis</topic><topic>Soft independent modelling of class analogy</topic><topic>Spectrometric and optical methods</topic><topic>Water</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fonseca, Alexandre</creatorcontrib><creatorcontrib>Raimundo, Ivo M.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Pollution Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fonseca, Alexandre</au><au>Raimundo, Ivo M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A simple method for water discrimination based on an light emitting diode (LED) photometer</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2007-07-16</date><risdate>2007</risdate><volume>596</volume><issue>1</issue><spage>66</spage><epage>72</epage><pages>66-72</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>This work describes the use of a multi-LED photometer for discrimination of mineral water samples, employing chromogenic reagents and chemometric techniques. Forty-five water samples (including 7 different brands of mineral water and samples of deionised, distilled and tap waters) were analysed in a monosegmented flow system, using three different chromogenic reagents (murexide, PAR and eriochrome black T) in a pH 10.0 NH 3/NH 4 + buffer in separate injections. Measurements were performed at 470, 500, 525, 562, 590, 612, 636 and 654 nm. Analyses were carried out using PCA, employing data sets including absorbance values obtained with one, two or all three reagents, which comprise 8, 16 or 24 variables, respectively. The best result was obtained with the data set from murexide and eriochrome black T, providing a clear distinction between 9 groups (distilled and deionised waters were classified in the same group). Based on the loading values, it was possible to select four wavelengths (470, 500, 590 and 654 nm) that provided a similar discrimination. With the use of these four LED, an HCA was performed, providing discrimination between 8 groups at a similarity level of 0.88. A model based on SIMCA allowed correctly classifying 94% of the samples. The discrimination between different groups is due to the metal ion contents in the water samples, mainly calcium and magnesium. Therefore, the use of common complexing reagents, such as murexide and erichrome black T, a multi-LED photometer and chemometric techniques provide an easy and simple method for water discrimination.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17616241</pmid><doi>10.1016/j.aca.2007.05.059</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2007-07, Vol.596 (1), p.66-72
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_70700464
source ScienceDirect Journals (5 years ago - present)
subjects Analytical chemistry
Chemistry
Exact sciences and technology
Hierarchical cluster analysis
Light emitting diode (LED)
Monosegmented flow
Pattern recognition
Photometry
Principal component analysis
Soft independent modelling of class analogy
Spectrometric and optical methods
Water
title A simple method for water discrimination based on an light emitting diode (LED) photometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T18%3A18%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20simple%20method%20for%20water%20discrimination%20based%20on%20an%20light%20emitting%20diode%20(LED)%20photometer&rft.jtitle=Analytica%20chimica%20acta&rft.au=Fonseca,%20Alexandre&rft.date=2007-07-16&rft.volume=596&rft.issue=1&rft.spage=66&rft.epage=72&rft.pages=66-72&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2007.05.059&rft_dat=%3Cproquest_cross%3E70700464%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20484159&rft_id=info:pmid/17616241&rft_els_id=S0003267007009919&rfr_iscdi=true