Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement

The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of anaesthesiology 2007-07, Vol.24 (7), p.589-595
Hauptverfasser: Jakobsen, C.-J., Torp, P., Sloth, E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 595
container_issue 7
container_start_page 589
container_title European journal of anaesthesiology
container_volume 24
creator Jakobsen, C.-J.
Torp, P.
Sloth, E.
description The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usable window for cardiac imaging in a mixed ICU population. The aim of this study was to evaluate the feasibility of perioperative imaging of the heart and pleura according to the focused assessed transthoracic echocardiography protocol in patients scheduled for aortic valve replacement. Thirty-five adult patients scheduled for aortic valve replacement were followed perioperatively with focused assessed transthoracic echocardiography examinations. A Vivid-7 echo-machine and a 2.5 MHz matrix transducer with second-harmonic imaging were used for data acquisition. The image quality for the cardiac window was graded 1-5 (1 = no image, 2 = poor and unusable image quality, 3 = usable image quality, 4 = good image quality and 5 = perfect image quality). A score >or=3 equalled an image quality judged to be of sufficient quality to be interpreted and thereby to contribute to clinical decision-making. All patients had at least one usable window preoperatively. At least one usable window was obtained in 88% of patients on the first postoperative day, and in 97% at discharge. The image quality changed over time, with the poorest quality being observed on the first postoperative day. The apical view with the patient in the left lateral position provided the best cardiac window on all occasions. The presence of drains did not significantly affect the achievability of a satisfactory examination. The number of patients with pleural effusion was relatively high. On the first postoperative day, 10 subjects had unilateral and one subject had bilateral pleural effusions. At discharge, 14 patients had unilateral and four patients had bilateral effusions. We conclude that the image quality of the heart and pleura, according to the focused assessed transthoracic echocardiography concept, is sufficient to undergo interpretation and thereby contribute to the perioperative clinical decision-making in patients with aortic stenosis.
doi_str_mv 10.1017/S0265021507000348
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_70616431</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cupid>10_1017_S0265021507000348</cupid><sourcerecordid>1458873331</sourcerecordid><originalsourceid>FETCH-LOGICAL-c195t-83e5c4f714e7acb6660428eb194d617ae4c3dbd458d2f4e8cb037096c64cb5403</originalsourceid><addsrcrecordid>eNplkUtPwzAQhC0EoqXwA7ggiwO3gB0_kh5RxUuqBBJwjhxnk7rKC9sp6oXfjqMWIcFpD_PN7GoWoXNKrimhyc0riaUgMRUkIYQwnh6gKWVSRDHj8hBNRzka9Qk6cW4dGBF8x2hCEy5jSuUUfb2ANV0PVnmzAVyCciY3tfFb3JXYNKoybYX9CvAKlPVYtQXuaxiswqbFfXBB6x3-NH6FVWe90dh5aDtnHB7aAmzVjQF7aaPqsMRCXysNTXCeoqNS1Q7O9nOG3u_v3haP0fL54Wlxu4w0nQsfpQyE5mVCOSRK51JKwuMUcjrnhaSJAq5ZkRdcpEVcckh1TlhC5lJLrnPBCZuhq11ub7uPAZzPGuM01LVqoRtclhBJJWc0gJd_wHU32DbclsU0rCWSyQBd7KEhb6DIehuKstvsp9YAsB2gVZNbU1TwG0NJNj4v-_c89g3IV4s4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>216600636</pqid></control><display><type>article</type><title>Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Jakobsen, C.-J. ; Torp, P. ; Sloth, E.</creator><creatorcontrib>Jakobsen, C.-J. ; Torp, P. ; Sloth, E.</creatorcontrib><description>The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usable window for cardiac imaging in a mixed ICU population. The aim of this study was to evaluate the feasibility of perioperative imaging of the heart and pleura according to the focused assessed transthoracic echocardiography protocol in patients scheduled for aortic valve replacement. Thirty-five adult patients scheduled for aortic valve replacement were followed perioperatively with focused assessed transthoracic echocardiography examinations. A Vivid-7 echo-machine and a 2.5 MHz matrix transducer with second-harmonic imaging were used for data acquisition. The image quality for the cardiac window was graded 1-5 (1 = no image, 2 = poor and unusable image quality, 3 = usable image quality, 4 = good image quality and 5 = perfect image quality). A score &gt;or=3 equalled an image quality judged to be of sufficient quality to be interpreted and thereby to contribute to clinical decision-making. All patients had at least one usable window preoperatively. At least one usable window was obtained in 88% of patients on the first postoperative day, and in 97% at discharge. The image quality changed over time, with the poorest quality being observed on the first postoperative day. The apical view with the patient in the left lateral position provided the best cardiac window on all occasions. The presence of drains did not significantly affect the achievability of a satisfactory examination. The number of patients with pleural effusion was relatively high. On the first postoperative day, 10 subjects had unilateral and one subject had bilateral pleural effusions. At discharge, 14 patients had unilateral and four patients had bilateral effusions. We conclude that the image quality of the heart and pleura, according to the focused assessed transthoracic echocardiography concept, is sufficient to undergo interpretation and thereby contribute to the perioperative clinical decision-making in patients with aortic stenosis.</description><identifier>ISSN: 0265-0215</identifier><identifier>EISSN: 1365-2346</identifier><identifier>DOI: 10.1017/S0265021507000348</identifier><identifier>PMID: 17462116</identifier><language>eng</language><publisher>Cambridge, UK: Cambridge University Press</publisher><subject>Adult ; Aortic Valve - surgery ; Aortic Valve Stenosis - diagnostic imaging ; Aortic Valve Stenosis - surgery ; Critical Care - methods ; Echocardiography - instrumentation ; Feasibility Studies ; Heart Valve Prosthesis Implantation - adverse effects ; Humans ; Image Interpretation, Computer-Assisted ; Perioperative Care - instrumentation ; Perioperative Care - methods ; Pleura - diagnostic imaging ; Pleural Effusion - diagnostic imaging ; Pleural Effusion - etiology ; Time Factors ; Treatment Outcome</subject><ispartof>European journal of anaesthesiology, 2007-07, Vol.24 (7), p.589-595</ispartof><rights>Copyright © European Society of Anaesthesiology 2007</rights><rights>European Society of Anaesthesiology</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17462116$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jakobsen, C.-J.</creatorcontrib><creatorcontrib>Torp, P.</creatorcontrib><creatorcontrib>Sloth, E.</creatorcontrib><title>Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement</title><title>European journal of anaesthesiology</title><addtitle>Eur J Anaesthesiol</addtitle><description>The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usable window for cardiac imaging in a mixed ICU population. The aim of this study was to evaluate the feasibility of perioperative imaging of the heart and pleura according to the focused assessed transthoracic echocardiography protocol in patients scheduled for aortic valve replacement. Thirty-five adult patients scheduled for aortic valve replacement were followed perioperatively with focused assessed transthoracic echocardiography examinations. A Vivid-7 echo-machine and a 2.5 MHz matrix transducer with second-harmonic imaging were used for data acquisition. The image quality for the cardiac window was graded 1-5 (1 = no image, 2 = poor and unusable image quality, 3 = usable image quality, 4 = good image quality and 5 = perfect image quality). A score &gt;or=3 equalled an image quality judged to be of sufficient quality to be interpreted and thereby to contribute to clinical decision-making. All patients had at least one usable window preoperatively. At least one usable window was obtained in 88% of patients on the first postoperative day, and in 97% at discharge. The image quality changed over time, with the poorest quality being observed on the first postoperative day. The apical view with the patient in the left lateral position provided the best cardiac window on all occasions. The presence of drains did not significantly affect the achievability of a satisfactory examination. The number of patients with pleural effusion was relatively high. On the first postoperative day, 10 subjects had unilateral and one subject had bilateral pleural effusions. At discharge, 14 patients had unilateral and four patients had bilateral effusions. We conclude that the image quality of the heart and pleura, according to the focused assessed transthoracic echocardiography concept, is sufficient to undergo interpretation and thereby contribute to the perioperative clinical decision-making in patients with aortic stenosis.</description><subject>Adult</subject><subject>Aortic Valve - surgery</subject><subject>Aortic Valve Stenosis - diagnostic imaging</subject><subject>Aortic Valve Stenosis - surgery</subject><subject>Critical Care - methods</subject><subject>Echocardiography - instrumentation</subject><subject>Feasibility Studies</subject><subject>Heart Valve Prosthesis Implantation - adverse effects</subject><subject>Humans</subject><subject>Image Interpretation, Computer-Assisted</subject><subject>Perioperative Care - instrumentation</subject><subject>Perioperative Care - methods</subject><subject>Pleura - diagnostic imaging</subject><subject>Pleural Effusion - diagnostic imaging</subject><subject>Pleural Effusion - etiology</subject><subject>Time Factors</subject><subject>Treatment Outcome</subject><issn>0265-0215</issn><issn>1365-2346</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkUtPwzAQhC0EoqXwA7ggiwO3gB0_kh5RxUuqBBJwjhxnk7rKC9sp6oXfjqMWIcFpD_PN7GoWoXNKrimhyc0riaUgMRUkIYQwnh6gKWVSRDHj8hBNRzka9Qk6cW4dGBF8x2hCEy5jSuUUfb2ANV0PVnmzAVyCciY3tfFb3JXYNKoybYX9CvAKlPVYtQXuaxiswqbFfXBB6x3-NH6FVWe90dh5aDtnHB7aAmzVjQF7aaPqsMRCXysNTXCeoqNS1Q7O9nOG3u_v3haP0fL54Wlxu4w0nQsfpQyE5mVCOSRK51JKwuMUcjrnhaSJAq5ZkRdcpEVcckh1TlhC5lJLrnPBCZuhq11ub7uPAZzPGuM01LVqoRtclhBJJWc0gJd_wHU32DbclsU0rCWSyQBd7KEhb6DIehuKstvsp9YAsB2gVZNbU1TwG0NJNj4v-_c89g3IV4s4</recordid><startdate>200707</startdate><enddate>200707</enddate><creator>Jakobsen, C.-J.</creator><creator>Torp, P.</creator><creator>Sloth, E.</creator><general>Cambridge University Press</general><general>Lippincott Williams &amp; Wilkins Ovid Technologies</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>200707</creationdate><title>Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement</title><author>Jakobsen, C.-J. ; Torp, P. ; Sloth, E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c195t-83e5c4f714e7acb6660428eb194d617ae4c3dbd458d2f4e8cb037096c64cb5403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Adult</topic><topic>Aortic Valve - surgery</topic><topic>Aortic Valve Stenosis - diagnostic imaging</topic><topic>Aortic Valve Stenosis - surgery</topic><topic>Critical Care - methods</topic><topic>Echocardiography - instrumentation</topic><topic>Feasibility Studies</topic><topic>Heart Valve Prosthesis Implantation - adverse effects</topic><topic>Humans</topic><topic>Image Interpretation, Computer-Assisted</topic><topic>Perioperative Care - instrumentation</topic><topic>Perioperative Care - methods</topic><topic>Pleura - diagnostic imaging</topic><topic>Pleural Effusion - diagnostic imaging</topic><topic>Pleural Effusion - etiology</topic><topic>Time Factors</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jakobsen, C.-J.</creatorcontrib><creatorcontrib>Torp, P.</creatorcontrib><creatorcontrib>Sloth, E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of anaesthesiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jakobsen, C.-J.</au><au>Torp, P.</au><au>Sloth, E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement</atitle><jtitle>European journal of anaesthesiology</jtitle><addtitle>Eur J Anaesthesiol</addtitle><date>2007-07</date><risdate>2007</risdate><volume>24</volume><issue>7</issue><spage>589</spage><epage>595</epage><pages>589-595</pages><issn>0265-0215</issn><eissn>1365-2346</eissn><abstract>The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usable window for cardiac imaging in a mixed ICU population. The aim of this study was to evaluate the feasibility of perioperative imaging of the heart and pleura according to the focused assessed transthoracic echocardiography protocol in patients scheduled for aortic valve replacement. Thirty-five adult patients scheduled for aortic valve replacement were followed perioperatively with focused assessed transthoracic echocardiography examinations. A Vivid-7 echo-machine and a 2.5 MHz matrix transducer with second-harmonic imaging were used for data acquisition. The image quality for the cardiac window was graded 1-5 (1 = no image, 2 = poor and unusable image quality, 3 = usable image quality, 4 = good image quality and 5 = perfect image quality). A score &gt;or=3 equalled an image quality judged to be of sufficient quality to be interpreted and thereby to contribute to clinical decision-making. All patients had at least one usable window preoperatively. At least one usable window was obtained in 88% of patients on the first postoperative day, and in 97% at discharge. The image quality changed over time, with the poorest quality being observed on the first postoperative day. The apical view with the patient in the left lateral position provided the best cardiac window on all occasions. The presence of drains did not significantly affect the achievability of a satisfactory examination. The number of patients with pleural effusion was relatively high. On the first postoperative day, 10 subjects had unilateral and one subject had bilateral pleural effusions. At discharge, 14 patients had unilateral and four patients had bilateral effusions. We conclude that the image quality of the heart and pleura, according to the focused assessed transthoracic echocardiography concept, is sufficient to undergo interpretation and thereby contribute to the perioperative clinical decision-making in patients with aortic stenosis.</abstract><cop>Cambridge, UK</cop><pub>Cambridge University Press</pub><pmid>17462116</pmid><doi>10.1017/S0265021507000348</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0265-0215
ispartof European journal of anaesthesiology, 2007-07, Vol.24 (7), p.589-595
issn 0265-0215
1365-2346
language eng
recordid cdi_proquest_miscellaneous_70616431
source MEDLINE; Journals@Ovid Complete
subjects Adult
Aortic Valve - surgery
Aortic Valve Stenosis - diagnostic imaging
Aortic Valve Stenosis - surgery
Critical Care - methods
Echocardiography - instrumentation
Feasibility Studies
Heart Valve Prosthesis Implantation - adverse effects
Humans
Image Interpretation, Computer-Assisted
Perioperative Care - instrumentation
Perioperative Care - methods
Pleura - diagnostic imaging
Pleural Effusion - diagnostic imaging
Pleural Effusion - etiology
Time Factors
Treatment Outcome
title Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T00%3A20%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Perioperative%20feasibility%20of%20imaging%20the%20heart%20and%20pleura%20in%20patients%20with%20aortic%20stenosis%20undergoing%20aortic%20valve%20replacement&rft.jtitle=European%20journal%20of%20anaesthesiology&rft.au=Jakobsen,%20C.-J.&rft.date=2007-07&rft.volume=24&rft.issue=7&rft.spage=589&rft.epage=595&rft.pages=589-595&rft.issn=0265-0215&rft.eissn=1365-2346&rft_id=info:doi/10.1017/S0265021507000348&rft_dat=%3Cproquest_pubme%3E1458873331%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=216600636&rft_id=info:pmid/17462116&rft_cupid=10_1017_S0265021507000348&rfr_iscdi=true