Fluoroscopic navigation system for hip surface replacement
Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reaso...
Gespeichert in:
Veröffentlicht in: | Computer aided surgery (New York, N.Y.) N.Y.), 2007-05, Vol.12 (3), p.160-167 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 167 |
---|---|
container_issue | 3 |
container_start_page | 160 |
container_title | Computer aided surgery (New York, N.Y.) |
container_volume | 12 |
creator | Belei, Peter Skwara, Adrian De La Fuente, Matías Schkommodau, Erik Fuchs, Susanne Wirtz, Dieter-C Kämper, Christian Radermacher, Klaus |
description | Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reasons for early implant failure are mal-orientation of the implant stem in relation to the femoral neck axis, and notching of the femoral neck during femoral head preparation, as well as by exposed cancellous bone after implantation. A computer-assisted planning and navigation system for the implantation of femoral hip resurfacing implants has been developed which supports the surgeon during intraoperative fluoroscopy-based planning and navigation of implant positioning. This paper presents the results of a cadaver study performed to evaluate the system's functionality and accuracy. |
doi_str_mv | 10.1080/10929080701336207 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70572239</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70572239</sourcerecordid><originalsourceid>FETCH-LOGICAL-c299t-764d81fae5b0cbaf033d7eea8ceb86791ec1a074106e8a2090786841fd55520e3</originalsourceid><addsrcrecordid>eNplkDFPwzAUhD2AaCn8ABaUiS3wbCexzYYqCkiVWGC2HOcZjJI42AlS_z2pWomB6Z5Odye9j5ArCrcUJNxRUEzNhwDKecVAnJDl3stnUy7IeUpfAKAqLs_IgoqSSyHlktxv2inEkGwYvM168-M_zOhDn6VdGrHLXIjZpx-yNEVnLGYRh3bWDvvxgpw60ya8POqKvG8e39bP-fb16WX9sM0tU2rMRVU0kjqDZQ22Ng44bwSikRZrWQlF0VIDoqBQoTQMFAhZyYK6pixLBshX5OawO8TwPWEadeeTxbY1PYYpaQGlYIyrOUgPQTs_lCI6PUTfmbjTFPQekv4Hae5cH8enusPmr3EkxH8BkSpjrg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70572239</pqid></control><display><type>article</type><title>Fluoroscopic navigation system for hip surface replacement</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Belei, Peter ; Skwara, Adrian ; De La Fuente, Matías ; Schkommodau, Erik ; Fuchs, Susanne ; Wirtz, Dieter-C ; Kämper, Christian ; Radermacher, Klaus</creator><creatorcontrib>Belei, Peter ; Skwara, Adrian ; De La Fuente, Matías ; Schkommodau, Erik ; Fuchs, Susanne ; Wirtz, Dieter-C ; Kämper, Christian ; Radermacher, Klaus</creatorcontrib><description>Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reasons for early implant failure are mal-orientation of the implant stem in relation to the femoral neck axis, and notching of the femoral neck during femoral head preparation, as well as by exposed cancellous bone after implantation. A computer-assisted planning and navigation system for the implantation of femoral hip resurfacing implants has been developed which supports the surgeon during intraoperative fluoroscopy-based planning and navigation of implant positioning. This paper presents the results of a cadaver study performed to evaluate the system's functionality and accuracy.</description><identifier>ISSN: 1092-9088</identifier><identifier>DOI: 10.1080/10929080701336207</identifier><identifier>PMID: 17538788</identifier><language>eng</language><publisher>England</publisher><subject>Arthroplasty, Replacement, Hip - instrumentation ; Calibration ; Feasibility Studies ; Femur Head - diagnostic imaging ; Femur Head - surgery ; Fluoroscopy - instrumentation ; Humans ; Image Processing, Computer-Assisted - instrumentation ; Imaging, Three-Dimensional - instrumentation ; Prosthesis Design ; Prosthesis Fitting ; Software ; Surgery, Computer-Assisted - instrumentation ; User-Computer Interface</subject><ispartof>Computer aided surgery (New York, N.Y.), 2007-05, Vol.12 (3), p.160-167</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c299t-764d81fae5b0cbaf033d7eea8ceb86791ec1a074106e8a2090786841fd55520e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17538788$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Belei, Peter</creatorcontrib><creatorcontrib>Skwara, Adrian</creatorcontrib><creatorcontrib>De La Fuente, Matías</creatorcontrib><creatorcontrib>Schkommodau, Erik</creatorcontrib><creatorcontrib>Fuchs, Susanne</creatorcontrib><creatorcontrib>Wirtz, Dieter-C</creatorcontrib><creatorcontrib>Kämper, Christian</creatorcontrib><creatorcontrib>Radermacher, Klaus</creatorcontrib><title>Fluoroscopic navigation system for hip surface replacement</title><title>Computer aided surgery (New York, N.Y.)</title><addtitle>Comput Aided Surg</addtitle><description>Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reasons for early implant failure are mal-orientation of the implant stem in relation to the femoral neck axis, and notching of the femoral neck during femoral head preparation, as well as by exposed cancellous bone after implantation. A computer-assisted planning and navigation system for the implantation of femoral hip resurfacing implants has been developed which supports the surgeon during intraoperative fluoroscopy-based planning and navigation of implant positioning. This paper presents the results of a cadaver study performed to evaluate the system's functionality and accuracy.</description><subject>Arthroplasty, Replacement, Hip - instrumentation</subject><subject>Calibration</subject><subject>Feasibility Studies</subject><subject>Femur Head - diagnostic imaging</subject><subject>Femur Head - surgery</subject><subject>Fluoroscopy - instrumentation</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - instrumentation</subject><subject>Imaging, Three-Dimensional - instrumentation</subject><subject>Prosthesis Design</subject><subject>Prosthesis Fitting</subject><subject>Software</subject><subject>Surgery, Computer-Assisted - instrumentation</subject><subject>User-Computer Interface</subject><issn>1092-9088</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkDFPwzAUhD2AaCn8ABaUiS3wbCexzYYqCkiVWGC2HOcZjJI42AlS_z2pWomB6Z5Odye9j5ArCrcUJNxRUEzNhwDKecVAnJDl3stnUy7IeUpfAKAqLs_IgoqSSyHlktxv2inEkGwYvM168-M_zOhDn6VdGrHLXIjZpx-yNEVnLGYRh3bWDvvxgpw60ya8POqKvG8e39bP-fb16WX9sM0tU2rMRVU0kjqDZQ22Ng44bwSikRZrWQlF0VIDoqBQoTQMFAhZyYK6pixLBshX5OawO8TwPWEadeeTxbY1PYYpaQGlYIyrOUgPQTs_lCI6PUTfmbjTFPQekv4Hae5cH8enusPmr3EkxH8BkSpjrg</recordid><startdate>200705</startdate><enddate>200705</enddate><creator>Belei, Peter</creator><creator>Skwara, Adrian</creator><creator>De La Fuente, Matías</creator><creator>Schkommodau, Erik</creator><creator>Fuchs, Susanne</creator><creator>Wirtz, Dieter-C</creator><creator>Kämper, Christian</creator><creator>Radermacher, Klaus</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200705</creationdate><title>Fluoroscopic navigation system for hip surface replacement</title><author>Belei, Peter ; Skwara, Adrian ; De La Fuente, Matías ; Schkommodau, Erik ; Fuchs, Susanne ; Wirtz, Dieter-C ; Kämper, Christian ; Radermacher, Klaus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c299t-764d81fae5b0cbaf033d7eea8ceb86791ec1a074106e8a2090786841fd55520e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Arthroplasty, Replacement, Hip - instrumentation</topic><topic>Calibration</topic><topic>Feasibility Studies</topic><topic>Femur Head - diagnostic imaging</topic><topic>Femur Head - surgery</topic><topic>Fluoroscopy - instrumentation</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - instrumentation</topic><topic>Imaging, Three-Dimensional - instrumentation</topic><topic>Prosthesis Design</topic><topic>Prosthesis Fitting</topic><topic>Software</topic><topic>Surgery, Computer-Assisted - instrumentation</topic><topic>User-Computer Interface</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Belei, Peter</creatorcontrib><creatorcontrib>Skwara, Adrian</creatorcontrib><creatorcontrib>De La Fuente, Matías</creatorcontrib><creatorcontrib>Schkommodau, Erik</creatorcontrib><creatorcontrib>Fuchs, Susanne</creatorcontrib><creatorcontrib>Wirtz, Dieter-C</creatorcontrib><creatorcontrib>Kämper, Christian</creatorcontrib><creatorcontrib>Radermacher, Klaus</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Computer aided surgery (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Belei, Peter</au><au>Skwara, Adrian</au><au>De La Fuente, Matías</au><au>Schkommodau, Erik</au><au>Fuchs, Susanne</au><au>Wirtz, Dieter-C</au><au>Kämper, Christian</au><au>Radermacher, Klaus</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fluoroscopic navigation system for hip surface replacement</atitle><jtitle>Computer aided surgery (New York, N.Y.)</jtitle><addtitle>Comput Aided Surg</addtitle><date>2007-05</date><risdate>2007</risdate><volume>12</volume><issue>3</issue><spage>160</spage><epage>167</epage><pages>160-167</pages><issn>1092-9088</issn><abstract>Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reasons for early implant failure are mal-orientation of the implant stem in relation to the femoral neck axis, and notching of the femoral neck during femoral head preparation, as well as by exposed cancellous bone after implantation. A computer-assisted planning and navigation system for the implantation of femoral hip resurfacing implants has been developed which supports the surgeon during intraoperative fluoroscopy-based planning and navigation of implant positioning. This paper presents the results of a cadaver study performed to evaluate the system's functionality and accuracy.</abstract><cop>England</cop><pmid>17538788</pmid><doi>10.1080/10929080701336207</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1092-9088 |
ispartof | Computer aided surgery (New York, N.Y.), 2007-05, Vol.12 (3), p.160-167 |
issn | 1092-9088 |
language | eng |
recordid | cdi_proquest_miscellaneous_70572239 |
source | MEDLINE; Alma/SFX Local Collection |
subjects | Arthroplasty, Replacement, Hip - instrumentation Calibration Feasibility Studies Femur Head - diagnostic imaging Femur Head - surgery Fluoroscopy - instrumentation Humans Image Processing, Computer-Assisted - instrumentation Imaging, Three-Dimensional - instrumentation Prosthesis Design Prosthesis Fitting Software Surgery, Computer-Assisted - instrumentation User-Computer Interface |
title | Fluoroscopic navigation system for hip surface replacement |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T17%3A55%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fluoroscopic%20navigation%20system%20for%20hip%20surface%20replacement&rft.jtitle=Computer%20aided%20surgery%20(New%20York,%20N.Y.)&rft.au=Belei,%20Peter&rft.date=2007-05&rft.volume=12&rft.issue=3&rft.spage=160&rft.epage=167&rft.pages=160-167&rft.issn=1092-9088&rft_id=info:doi/10.1080/10929080701336207&rft_dat=%3Cproquest_cross%3E70572239%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70572239&rft_id=info:pmid/17538788&rfr_iscdi=true |