An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique

Objective The objective of this study was to compare, in vivo, the accuracy of working length determination using only the Root-ZX electronic apex locator versus adjusting Root-ZX measurements after obtaining a working length radiograph. Study design The working length was determined in 25 premolar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Oral surgery, oral medicine, oral pathology, oral radiology and endodontics oral medicine, oral pathology, oral radiology and endodontics, 2008-04, Vol.105 (4), p.e79-e83
Hauptverfasser: Kim, Euiseong, DDS, MSD, PhD, Marmo, Michael, DMD, Lee, Chan-Young, DDS, MSD, PhD, Oh, Nam-Sik, DDS, MSD, PhD, Kim, Il-Kyu, DDS, MSD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e83
container_issue 4
container_start_page e79
container_title Oral surgery, oral medicine, oral pathology, oral radiology and endodontics
container_volume 105
creator Kim, Euiseong, DDS, MSD, PhD
Marmo, Michael, DMD
Lee, Chan-Young, DDS, MSD, PhD
Oh, Nam-Sik, DDS, MSD, PhD
Kim, Il-Kyu, DDS, MSD, PhD
description Objective The objective of this study was to compare, in vivo, the accuracy of working length determination using only the Root-ZX electronic apex locator versus adjusting Root-ZX measurements after obtaining a working length radiograph. Study design The working length was determined in 25 premolar root canals using Root-ZX and K-files were fixed at these positions. Radiographs were acquired and interpreted, and the recorded working length measurement was adjusted, if necessary, for a combined measurement. The teeth were then extracted in an effort to determine the position of the file tip to the root canal constriction. On the basis of the position of the file tip to the apical foramen, polyvinylsiloxane impressions of the root apex were taken, or the root was imbedded in acrylic resin and ground in order to measure the position of the file tip to the apical constriction. Results The Root-ZX alone detected the apical constriction within ± 0.5 mm in 84% of the samples (21 of 25 canals). However, 96% (24 of 25 canals) were within this range when the combination of Root-ZX and radiographs was used. We noted no statistical significance between these 2 methods ( P > .05). Conclusion Using a Root ZX Electronic Apex Locator combined with radiographs is recommended for the determination of working length, although there was no statistical significance between those 2 groups in this study.
doi_str_mv 10.1016/j.tripleo.2007.12.009
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70384335</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1079210407009274</els_id><sourcerecordid>70384335</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-908d2035bb86e61efce4583c2f5c01af41eff487f77f9e12e1c682fd99ab59333</originalsourceid><addsrcrecordid>eNqFkl2L1DAYhYso7rr6E5Rcedeaj6ZtbpRlWT9gwQsVFm9Cmr6ZyWyb1CSdcf6Sv9KUGRBE8Cohec45JOctipcEVwST5s2uSsHOI_iKYtxWhFYYi0fFJeG0K5ng94_zHreipATXF8WzGHcY44YJ8bS4IB2jgrf0svh17ZB1aG_3Hmk_zSrY6B3yBh18eLBug0Zwm7RFAyQIk3Uq2XzfH5F34xEF71P5_R6pGX6i0WuVfEB7CHGJq11v3WrxT-pgs2tQg_WboOZtREtcWYUcHJCd5gAxrlEJ9NbZHws8L54YNUZ4cV6vim_vb7_efCzvPn_4dHN9V-qadKkUuBsoZrzvuwYaAkZDzTumqeEaE2XqfGTqrjVtawQQCkQ3HTWDEKrngjF2Vbw--c7B59iY5GSjhnFUDvwSZYtZVzPGM8hPoA4-xgBGzsFOKhwlwXItSe7kuSS5liQJlbmkrHt1Dlj6CYY_qnMrGXh3AiA_c28hyKgtOA2DDaCTHLz9b8Tbvxz0mLvQanyAI8SdX4LLfyiJjFkgv6yTsg4KbrOatjX7DfS4v9g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70384335</pqid></control><display><type>article</type><title>An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Kim, Euiseong, DDS, MSD, PhD ; Marmo, Michael, DMD ; Lee, Chan-Young, DDS, MSD, PhD ; Oh, Nam-Sik, DDS, MSD, PhD ; Kim, Il-Kyu, DDS, MSD, PhD</creator><creatorcontrib>Kim, Euiseong, DDS, MSD, PhD ; Marmo, Michael, DMD ; Lee, Chan-Young, DDS, MSD, PhD ; Oh, Nam-Sik, DDS, MSD, PhD ; Kim, Il-Kyu, DDS, MSD, PhD</creatorcontrib><description>Objective The objective of this study was to compare, in vivo, the accuracy of working length determination using only the Root-ZX electronic apex locator versus adjusting Root-ZX measurements after obtaining a working length radiograph. Study design The working length was determined in 25 premolar root canals using Root-ZX and K-files were fixed at these positions. Radiographs were acquired and interpreted, and the recorded working length measurement was adjusted, if necessary, for a combined measurement. The teeth were then extracted in an effort to determine the position of the file tip to the root canal constriction. On the basis of the position of the file tip to the apical foramen, polyvinylsiloxane impressions of the root apex were taken, or the root was imbedded in acrylic resin and ground in order to measure the position of the file tip to the apical constriction. Results The Root-ZX alone detected the apical constriction within ± 0.5 mm in 84% of the samples (21 of 25 canals). However, 96% (24 of 25 canals) were within this range when the combination of Root-ZX and radiographs was used. We noted no statistical significance between these 2 methods ( P &gt; .05). Conclusion Using a Root ZX Electronic Apex Locator combined with radiographs is recommended for the determination of working length, although there was no statistical significance between those 2 groups in this study.</description><identifier>ISSN: 1079-2104</identifier><identifier>EISSN: 1528-395X</identifier><identifier>DOI: 10.1016/j.tripleo.2007.12.009</identifier><identifier>PMID: 18329572</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Bicuspid - anatomy &amp; histology ; Bicuspid - diagnostic imaging ; Chi-Square Distribution ; Dental Impression Technique ; Dental Instruments ; Dental Pulp Cavity - anatomy &amp; histology ; Dental Pulp Cavity - diagnostic imaging ; Dentistry ; Glass Ionomer Cements ; Humans ; Odontometry - instrumentation ; Radiography ; Root Canal Preparation - instrumentation ; Surgery ; Tooth Apex - anatomy &amp; histology ; Tooth Apex - diagnostic imaging</subject><ispartof>Oral surgery, oral medicine, oral pathology, oral radiology and endodontics, 2008-04, Vol.105 (4), p.e79-e83</ispartof><rights>Mosby, Inc.</rights><rights>2008 Mosby, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-908d2035bb86e61efce4583c2f5c01af41eff487f77f9e12e1c682fd99ab59333</citedby><cites>FETCH-LOGICAL-c418t-908d2035bb86e61efce4583c2f5c01af41eff487f77f9e12e1c682fd99ab59333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1079210407009274$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18329572$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, Euiseong, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Marmo, Michael, DMD</creatorcontrib><creatorcontrib>Lee, Chan-Young, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Oh, Nam-Sik, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Kim, Il-Kyu, DDS, MSD, PhD</creatorcontrib><title>An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique</title><title>Oral surgery, oral medicine, oral pathology, oral radiology and endodontics</title><addtitle>Oral Surg Oral Med Oral Pathol Oral Radiol Endod</addtitle><description>Objective The objective of this study was to compare, in vivo, the accuracy of working length determination using only the Root-ZX electronic apex locator versus adjusting Root-ZX measurements after obtaining a working length radiograph. Study design The working length was determined in 25 premolar root canals using Root-ZX and K-files were fixed at these positions. Radiographs were acquired and interpreted, and the recorded working length measurement was adjusted, if necessary, for a combined measurement. The teeth were then extracted in an effort to determine the position of the file tip to the root canal constriction. On the basis of the position of the file tip to the apical foramen, polyvinylsiloxane impressions of the root apex were taken, or the root was imbedded in acrylic resin and ground in order to measure the position of the file tip to the apical constriction. Results The Root-ZX alone detected the apical constriction within ± 0.5 mm in 84% of the samples (21 of 25 canals). However, 96% (24 of 25 canals) were within this range when the combination of Root-ZX and radiographs was used. We noted no statistical significance between these 2 methods ( P &gt; .05). Conclusion Using a Root ZX Electronic Apex Locator combined with radiographs is recommended for the determination of working length, although there was no statistical significance between those 2 groups in this study.</description><subject>Bicuspid - anatomy &amp; histology</subject><subject>Bicuspid - diagnostic imaging</subject><subject>Chi-Square Distribution</subject><subject>Dental Impression Technique</subject><subject>Dental Instruments</subject><subject>Dental Pulp Cavity - anatomy &amp; histology</subject><subject>Dental Pulp Cavity - diagnostic imaging</subject><subject>Dentistry</subject><subject>Glass Ionomer Cements</subject><subject>Humans</subject><subject>Odontometry - instrumentation</subject><subject>Radiography</subject><subject>Root Canal Preparation - instrumentation</subject><subject>Surgery</subject><subject>Tooth Apex - anatomy &amp; histology</subject><subject>Tooth Apex - diagnostic imaging</subject><issn>1079-2104</issn><issn>1528-395X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkl2L1DAYhYso7rr6E5Rcedeaj6ZtbpRlWT9gwQsVFm9Cmr6ZyWyb1CSdcf6Sv9KUGRBE8Cohec45JOctipcEVwST5s2uSsHOI_iKYtxWhFYYi0fFJeG0K5ng94_zHreipATXF8WzGHcY44YJ8bS4IB2jgrf0svh17ZB1aG_3Hmk_zSrY6B3yBh18eLBug0Zwm7RFAyQIk3Uq2XzfH5F34xEF71P5_R6pGX6i0WuVfEB7CHGJq11v3WrxT-pgs2tQg_WboOZtREtcWYUcHJCd5gAxrlEJ9NbZHws8L54YNUZ4cV6vim_vb7_efCzvPn_4dHN9V-qadKkUuBsoZrzvuwYaAkZDzTumqeEaE2XqfGTqrjVtawQQCkQ3HTWDEKrngjF2Vbw--c7B59iY5GSjhnFUDvwSZYtZVzPGM8hPoA4-xgBGzsFOKhwlwXItSe7kuSS5liQJlbmkrHt1Dlj6CYY_qnMrGXh3AiA_c28hyKgtOA2DDaCTHLz9b8Tbvxz0mLvQanyAI8SdX4LLfyiJjFkgv6yTsg4KbrOatjX7DfS4v9g</recordid><startdate>20080401</startdate><enddate>20080401</enddate><creator>Kim, Euiseong, DDS, MSD, PhD</creator><creator>Marmo, Michael, DMD</creator><creator>Lee, Chan-Young, DDS, MSD, PhD</creator><creator>Oh, Nam-Sik, DDS, MSD, PhD</creator><creator>Kim, Il-Kyu, DDS, MSD, PhD</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20080401</creationdate><title>An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique</title><author>Kim, Euiseong, DDS, MSD, PhD ; Marmo, Michael, DMD ; Lee, Chan-Young, DDS, MSD, PhD ; Oh, Nam-Sik, DDS, MSD, PhD ; Kim, Il-Kyu, DDS, MSD, PhD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-908d2035bb86e61efce4583c2f5c01af41eff487f77f9e12e1c682fd99ab59333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Bicuspid - anatomy &amp; histology</topic><topic>Bicuspid - diagnostic imaging</topic><topic>Chi-Square Distribution</topic><topic>Dental Impression Technique</topic><topic>Dental Instruments</topic><topic>Dental Pulp Cavity - anatomy &amp; histology</topic><topic>Dental Pulp Cavity - diagnostic imaging</topic><topic>Dentistry</topic><topic>Glass Ionomer Cements</topic><topic>Humans</topic><topic>Odontometry - instrumentation</topic><topic>Radiography</topic><topic>Root Canal Preparation - instrumentation</topic><topic>Surgery</topic><topic>Tooth Apex - anatomy &amp; histology</topic><topic>Tooth Apex - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Euiseong, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Marmo, Michael, DMD</creatorcontrib><creatorcontrib>Lee, Chan-Young, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Oh, Nam-Sik, DDS, MSD, PhD</creatorcontrib><creatorcontrib>Kim, Il-Kyu, DDS, MSD, PhD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Oral surgery, oral medicine, oral pathology, oral radiology and endodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Euiseong, DDS, MSD, PhD</au><au>Marmo, Michael, DMD</au><au>Lee, Chan-Young, DDS, MSD, PhD</au><au>Oh, Nam-Sik, DDS, MSD, PhD</au><au>Kim, Il-Kyu, DDS, MSD, PhD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique</atitle><jtitle>Oral surgery, oral medicine, oral pathology, oral radiology and endodontics</jtitle><addtitle>Oral Surg Oral Med Oral Pathol Oral Radiol Endod</addtitle><date>2008-04-01</date><risdate>2008</risdate><volume>105</volume><issue>4</issue><spage>e79</spage><epage>e83</epage><pages>e79-e83</pages><issn>1079-2104</issn><eissn>1528-395X</eissn><abstract>Objective The objective of this study was to compare, in vivo, the accuracy of working length determination using only the Root-ZX electronic apex locator versus adjusting Root-ZX measurements after obtaining a working length radiograph. Study design The working length was determined in 25 premolar root canals using Root-ZX and K-files were fixed at these positions. Radiographs were acquired and interpreted, and the recorded working length measurement was adjusted, if necessary, for a combined measurement. The teeth were then extracted in an effort to determine the position of the file tip to the root canal constriction. On the basis of the position of the file tip to the apical foramen, polyvinylsiloxane impressions of the root apex were taken, or the root was imbedded in acrylic resin and ground in order to measure the position of the file tip to the apical constriction. Results The Root-ZX alone detected the apical constriction within ± 0.5 mm in 84% of the samples (21 of 25 canals). However, 96% (24 of 25 canals) were within this range when the combination of Root-ZX and radiographs was used. We noted no statistical significance between these 2 methods ( P &gt; .05). Conclusion Using a Root ZX Electronic Apex Locator combined with radiographs is recommended for the determination of working length, although there was no statistical significance between those 2 groups in this study.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>18329572</pmid><doi>10.1016/j.tripleo.2007.12.009</doi></addata></record>
fulltext fulltext
identifier ISSN: 1079-2104
ispartof Oral surgery, oral medicine, oral pathology, oral radiology and endodontics, 2008-04, Vol.105 (4), p.e79-e83
issn 1079-2104
1528-395X
language eng
recordid cdi_proquest_miscellaneous_70384335
source MEDLINE; Elsevier ScienceDirect Journals
subjects Bicuspid - anatomy & histology
Bicuspid - diagnostic imaging
Chi-Square Distribution
Dental Impression Technique
Dental Instruments
Dental Pulp Cavity - anatomy & histology
Dental Pulp Cavity - diagnostic imaging
Dentistry
Glass Ionomer Cements
Humans
Odontometry - instrumentation
Radiography
Root Canal Preparation - instrumentation
Surgery
Tooth Apex - anatomy & histology
Tooth Apex - diagnostic imaging
title An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T04%3A41%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20in%20vivo%20comparison%20of%20working%20length%20determination%20by%20only%20root-ZX%20apex%20locator%20versus%20combining%20root-ZX%20apex%20locator%20with%20radiographs%20using%20a%20new%20impression%20technique&rft.jtitle=Oral%20surgery,%20oral%20medicine,%20oral%20pathology,%20oral%20radiology%20and%20endodontics&rft.au=Kim,%20Euiseong,%20DDS,%20MSD,%20PhD&rft.date=2008-04-01&rft.volume=105&rft.issue=4&rft.spage=e79&rft.epage=e83&rft.pages=e79-e83&rft.issn=1079-2104&rft.eissn=1528-395X&rft_id=info:doi/10.1016/j.tripleo.2007.12.009&rft_dat=%3Cproquest_cross%3E70384335%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70384335&rft_id=info:pmid/18329572&rft_els_id=S1079210407009274&rfr_iscdi=true