Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model

Good quality basic life support (BLS) improves outcome during cardiac arrest. As fatigue may reduce BLS performance over time we wanted to examine the quality of chest compressions in a single-rescuer scenario during prolonged BLS with different compression:ventilation ratios (C:V ratios). Professio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Resuscitation 2008-04, Vol.77 (1), p.95-100
Hauptverfasser: Bjørshol, Conrad Arnfinn, Søreide, Eldar, Torsteinbø, Tor Harald, Lexow, Kristian, Nilsen, Odd Bjarte, Sunde, Kjetil
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 100
container_issue 1
container_start_page 95
container_title Resuscitation
container_volume 77
creator Bjørshol, Conrad Arnfinn
Søreide, Eldar
Torsteinbø, Tor Harald
Lexow, Kristian
Nilsen, Odd Bjarte
Sunde, Kjetil
description Good quality basic life support (BLS) improves outcome during cardiac arrest. As fatigue may reduce BLS performance over time we wanted to examine the quality of chest compressions in a single-rescuer scenario during prolonged BLS with different compression:ventilation ratios (C:V ratios). Professional paramedics were asked to perform single-rescuer BLS with C:V ratios of 15:2, 30:2 and 50:2 for 10 min each in random order. A Laerdal Medical Resusci Anne Simulator with PC Skillreporting System was used for BLS quality analysis. Total number of chest compressions, compression depth and compression rate were measured and the differences between the C:V ratios were analysed with repeated measures ANOVA. For analysis of fatigue, chest compression variables for each 2-min period were analysed and compared with the first 2-min period using repeated measures ANOVA. Altogether 50 paramedics completed the study. The mean number of chest compressions increased significantly from 604 to 770 and 862 with C:V ratios of 15:2, 30:2 and 50:2, respectively. Chest compression rate was significantly higher with C:V ratio of 15:2 compared to 30:2 and 50:2 but was above 100 per minute for all three ratios. However, the mean chest compression depth did not change significantly between the different C:V ratios. The number of chest compressions did not change significantly with time for any of the three C:V ratios. Compression depth did decline after the first 2-min period for 30:2 and 50:2 as did compression rate for all three ratios. However all were above the guideline limits for the entire test period. Increasing the C:V ratio increases the number of chest compressions during 10 min of BLS. Compression depth and compression rate were within guideline recommendations for all three ratios. We found no decline in chest compression quality below guideline recommendations during 10 min of BLS with any of the three different C:V ratios.
doi_str_mv 10.1016/j.resuscitation.2007.11.009
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70371464</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70371464</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1647-b6d69a0b4b2aeaaf632ae53807b2a11fff979b1f5421eede5e6b61d85c4d3f3e3</originalsourceid><addsrcrecordid>eNpVkd1q3DAQhXXRkmyTvEIRFHpnZ8aypXV7VUKaBAKlkFwLWR4l2vivkp2yj9E3jja7UPbqSDNnPmk4jH1ByBFQXm7yQHGJ1s9m9uOQFwAqR8wB6g9sBQIgqytVnLJPMW4AQFS1OmGnuC5AyUKt2L_fi-n8vOWj4_aZ4szt2E8JGhMu8nYJfnjiCL0fdpaYbh1lqW8XCrwx0VveeUc8LtM0hpn_9fMzb71zFGg4on3jr6niu_ef8rCTyBPW8N4M_iWd-rGl7px9dKaLdHHQM_b48_rh6ja7_3Vzd_XjPrMoS5U1spW1gaZsCkPGOCmSVmINKhUQnXO1qht0VVkgUUsVyUZiu65s2QonSJyxr3vuFMY_S9pc9z5a6joz0LhErUAoLGWZjN_3RhvGGAM5PQXfm7DVCHqXgt7ooxT0LgWNqFMKafrz4Zml6an9P3uIQLwBvFSPmg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70371464</pqid></control><display><type>article</type><title>Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Bjørshol, Conrad Arnfinn ; Søreide, Eldar ; Torsteinbø, Tor Harald ; Lexow, Kristian ; Nilsen, Odd Bjarte ; Sunde, Kjetil</creator><creatorcontrib>Bjørshol, Conrad Arnfinn ; Søreide, Eldar ; Torsteinbø, Tor Harald ; Lexow, Kristian ; Nilsen, Odd Bjarte ; Sunde, Kjetil</creatorcontrib><description>Good quality basic life support (BLS) improves outcome during cardiac arrest. As fatigue may reduce BLS performance over time we wanted to examine the quality of chest compressions in a single-rescuer scenario during prolonged BLS with different compression:ventilation ratios (C:V ratios). Professional paramedics were asked to perform single-rescuer BLS with C:V ratios of 15:2, 30:2 and 50:2 for 10 min each in random order. A Laerdal Medical Resusci Anne Simulator with PC Skillreporting System was used for BLS quality analysis. Total number of chest compressions, compression depth and compression rate were measured and the differences between the C:V ratios were analysed with repeated measures ANOVA. For analysis of fatigue, chest compression variables for each 2-min period were analysed and compared with the first 2-min period using repeated measures ANOVA. Altogether 50 paramedics completed the study. The mean number of chest compressions increased significantly from 604 to 770 and 862 with C:V ratios of 15:2, 30:2 and 50:2, respectively. Chest compression rate was significantly higher with C:V ratio of 15:2 compared to 30:2 and 50:2 but was above 100 per minute for all three ratios. However, the mean chest compression depth did not change significantly between the different C:V ratios. The number of chest compressions did not change significantly with time for any of the three C:V ratios. Compression depth did decline after the first 2-min period for 30:2 and 50:2 as did compression rate for all three ratios. However all were above the guideline limits for the entire test period. Increasing the C:V ratio increases the number of chest compressions during 10 min of BLS. Compression depth and compression rate were within guideline recommendations for all three ratios. We found no decline in chest compression quality below guideline recommendations during 10 min of BLS with any of the three different C:V ratios.</description><identifier>ISSN: 0300-9572</identifier><identifier>DOI: 10.1016/j.resuscitation.2007.11.009</identifier><identifier>PMID: 18207627</identifier><language>eng</language><publisher>Ireland</publisher><subject>Allied Health Personnel - education ; Analysis of Variance ; Cardiopulmonary Resuscitation - methods ; Cardiopulmonary Resuscitation - standards ; Heart Arrest - therapy ; Heart Massage - methods ; Heart Massage - standards ; Humans ; Manikins ; Pulmonary Ventilation ; Quality of Health Care</subject><ispartof>Resuscitation, 2008-04, Vol.77 (1), p.95-100</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1647-b6d69a0b4b2aeaaf632ae53807b2a11fff979b1f5421eede5e6b61d85c4d3f3e3</citedby><cites>FETCH-LOGICAL-c1647-b6d69a0b4b2aeaaf632ae53807b2a11fff979b1f5421eede5e6b61d85c4d3f3e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18207627$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bjørshol, Conrad Arnfinn</creatorcontrib><creatorcontrib>Søreide, Eldar</creatorcontrib><creatorcontrib>Torsteinbø, Tor Harald</creatorcontrib><creatorcontrib>Lexow, Kristian</creatorcontrib><creatorcontrib>Nilsen, Odd Bjarte</creatorcontrib><creatorcontrib>Sunde, Kjetil</creatorcontrib><title>Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model</title><title>Resuscitation</title><addtitle>Resuscitation</addtitle><description>Good quality basic life support (BLS) improves outcome during cardiac arrest. As fatigue may reduce BLS performance over time we wanted to examine the quality of chest compressions in a single-rescuer scenario during prolonged BLS with different compression:ventilation ratios (C:V ratios). Professional paramedics were asked to perform single-rescuer BLS with C:V ratios of 15:2, 30:2 and 50:2 for 10 min each in random order. A Laerdal Medical Resusci Anne Simulator with PC Skillreporting System was used for BLS quality analysis. Total number of chest compressions, compression depth and compression rate were measured and the differences between the C:V ratios were analysed with repeated measures ANOVA. For analysis of fatigue, chest compression variables for each 2-min period were analysed and compared with the first 2-min period using repeated measures ANOVA. Altogether 50 paramedics completed the study. The mean number of chest compressions increased significantly from 604 to 770 and 862 with C:V ratios of 15:2, 30:2 and 50:2, respectively. Chest compression rate was significantly higher with C:V ratio of 15:2 compared to 30:2 and 50:2 but was above 100 per minute for all three ratios. However, the mean chest compression depth did not change significantly between the different C:V ratios. The number of chest compressions did not change significantly with time for any of the three C:V ratios. Compression depth did decline after the first 2-min period for 30:2 and 50:2 as did compression rate for all three ratios. However all were above the guideline limits for the entire test period. Increasing the C:V ratio increases the number of chest compressions during 10 min of BLS. Compression depth and compression rate were within guideline recommendations for all three ratios. We found no decline in chest compression quality below guideline recommendations during 10 min of BLS with any of the three different C:V ratios.</description><subject>Allied Health Personnel - education</subject><subject>Analysis of Variance</subject><subject>Cardiopulmonary Resuscitation - methods</subject><subject>Cardiopulmonary Resuscitation - standards</subject><subject>Heart Arrest - therapy</subject><subject>Heart Massage - methods</subject><subject>Heart Massage - standards</subject><subject>Humans</subject><subject>Manikins</subject><subject>Pulmonary Ventilation</subject><subject>Quality of Health Care</subject><issn>0300-9572</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkd1q3DAQhXXRkmyTvEIRFHpnZ8aypXV7VUKaBAKlkFwLWR4l2vivkp2yj9E3jja7UPbqSDNnPmk4jH1ByBFQXm7yQHGJ1s9m9uOQFwAqR8wB6g9sBQIgqytVnLJPMW4AQFS1OmGnuC5AyUKt2L_fi-n8vOWj4_aZ4szt2E8JGhMu8nYJfnjiCL0fdpaYbh1lqW8XCrwx0VveeUc8LtM0hpn_9fMzb71zFGg4on3jr6niu_ef8rCTyBPW8N4M_iWd-rGl7px9dKaLdHHQM_b48_rh6ja7_3Vzd_XjPrMoS5U1spW1gaZsCkPGOCmSVmINKhUQnXO1qht0VVkgUUsVyUZiu65s2QonSJyxr3vuFMY_S9pc9z5a6joz0LhErUAoLGWZjN_3RhvGGAM5PQXfm7DVCHqXgt7ooxT0LgWNqFMKafrz4Zml6an9P3uIQLwBvFSPmg</recordid><startdate>200804</startdate><enddate>200804</enddate><creator>Bjørshol, Conrad Arnfinn</creator><creator>Søreide, Eldar</creator><creator>Torsteinbø, Tor Harald</creator><creator>Lexow, Kristian</creator><creator>Nilsen, Odd Bjarte</creator><creator>Sunde, Kjetil</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200804</creationdate><title>Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model</title><author>Bjørshol, Conrad Arnfinn ; Søreide, Eldar ; Torsteinbø, Tor Harald ; Lexow, Kristian ; Nilsen, Odd Bjarte ; Sunde, Kjetil</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1647-b6d69a0b4b2aeaaf632ae53807b2a11fff979b1f5421eede5e6b61d85c4d3f3e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Allied Health Personnel - education</topic><topic>Analysis of Variance</topic><topic>Cardiopulmonary Resuscitation - methods</topic><topic>Cardiopulmonary Resuscitation - standards</topic><topic>Heart Arrest - therapy</topic><topic>Heart Massage - methods</topic><topic>Heart Massage - standards</topic><topic>Humans</topic><topic>Manikins</topic><topic>Pulmonary Ventilation</topic><topic>Quality of Health Care</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bjørshol, Conrad Arnfinn</creatorcontrib><creatorcontrib>Søreide, Eldar</creatorcontrib><creatorcontrib>Torsteinbø, Tor Harald</creatorcontrib><creatorcontrib>Lexow, Kristian</creatorcontrib><creatorcontrib>Nilsen, Odd Bjarte</creatorcontrib><creatorcontrib>Sunde, Kjetil</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Resuscitation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bjørshol, Conrad Arnfinn</au><au>Søreide, Eldar</au><au>Torsteinbø, Tor Harald</au><au>Lexow, Kristian</au><au>Nilsen, Odd Bjarte</au><au>Sunde, Kjetil</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model</atitle><jtitle>Resuscitation</jtitle><addtitle>Resuscitation</addtitle><date>2008-04</date><risdate>2008</risdate><volume>77</volume><issue>1</issue><spage>95</spage><epage>100</epage><pages>95-100</pages><issn>0300-9572</issn><abstract>Good quality basic life support (BLS) improves outcome during cardiac arrest. As fatigue may reduce BLS performance over time we wanted to examine the quality of chest compressions in a single-rescuer scenario during prolonged BLS with different compression:ventilation ratios (C:V ratios). Professional paramedics were asked to perform single-rescuer BLS with C:V ratios of 15:2, 30:2 and 50:2 for 10 min each in random order. A Laerdal Medical Resusci Anne Simulator with PC Skillreporting System was used for BLS quality analysis. Total number of chest compressions, compression depth and compression rate were measured and the differences between the C:V ratios were analysed with repeated measures ANOVA. For analysis of fatigue, chest compression variables for each 2-min period were analysed and compared with the first 2-min period using repeated measures ANOVA. Altogether 50 paramedics completed the study. The mean number of chest compressions increased significantly from 604 to 770 and 862 with C:V ratios of 15:2, 30:2 and 50:2, respectively. Chest compression rate was significantly higher with C:V ratio of 15:2 compared to 30:2 and 50:2 but was above 100 per minute for all three ratios. However, the mean chest compression depth did not change significantly between the different C:V ratios. The number of chest compressions did not change significantly with time for any of the three C:V ratios. Compression depth did decline after the first 2-min period for 30:2 and 50:2 as did compression rate for all three ratios. However all were above the guideline limits for the entire test period. Increasing the C:V ratio increases the number of chest compressions during 10 min of BLS. Compression depth and compression rate were within guideline recommendations for all three ratios. We found no decline in chest compression quality below guideline recommendations during 10 min of BLS with any of the three different C:V ratios.</abstract><cop>Ireland</cop><pmid>18207627</pmid><doi>10.1016/j.resuscitation.2007.11.009</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0300-9572
ispartof Resuscitation, 2008-04, Vol.77 (1), p.95-100
issn 0300-9572
language eng
recordid cdi_proquest_miscellaneous_70371464
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Allied Health Personnel - education
Analysis of Variance
Cardiopulmonary Resuscitation - methods
Cardiopulmonary Resuscitation - standards
Heart Arrest - therapy
Heart Massage - methods
Heart Massage - standards
Humans
Manikins
Pulmonary Ventilation
Quality of Health Care
title Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T10%3A05%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quality%20of%20chest%20compressions%20during%2010min%20of%20single-rescuer%20basic%20life%20support%20with%20different%20compression:%20ventilation%20ratios%20in%20a%20manikin%20model&rft.jtitle=Resuscitation&rft.au=Bj%C3%B8rshol,%20Conrad%20Arnfinn&rft.date=2008-04&rft.volume=77&rft.issue=1&rft.spage=95&rft.epage=100&rft.pages=95-100&rft.issn=0300-9572&rft_id=info:doi/10.1016/j.resuscitation.2007.11.009&rft_dat=%3Cproquest_cross%3E70371464%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70371464&rft_id=info:pmid/18207627&rfr_iscdi=true