Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device

A home screening device, LT-200, can record data on both breathing conditions and body positions during sleep for up to 3 consecutive days in patients with obstructive sleep apnea (OSAS). We investigated the usefulness of the LT-200 device for follow-up of OSAS. Eighteen patients (age 51.0 +/- 10.8...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nagoya journal of medical science 2007, Vol.69 (1-2), p.37-43
Hauptverfasser: Miyata, Seiko, Noda, Akiko, Honda, Kumiko, Nakata, Seiichi, Suzuki, Keisuke, Nakashima, Tsutomu, Koike, Yasuo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 43
container_issue 1-2
container_start_page 37
container_title Nagoya journal of medical science
container_volume 69
creator Miyata, Seiko
Noda, Akiko
Honda, Kumiko
Nakata, Seiichi
Suzuki, Keisuke
Nakashima, Tsutomu
Koike, Yasuo
description A home screening device, LT-200, can record data on both breathing conditions and body positions during sleep for up to 3 consecutive days in patients with obstructive sleep apnea (OSAS). We investigated the usefulness of the LT-200 device for follow-up of OSAS. Eighteen patients (age 51.0 +/- 10.8 years, mean +/- SD) were enrolled in this study. Standard polysomnography (PSG) was performed on all patients. The number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI), the total time that nocturnal oxygen saturation was < 90% (oxygen desaturation time: ODT), and the minimum oxygen saturation during sleep (lowest Spo2) were calculated. We used the LT-200 and PSG to evaluate any improvement in the data obtained after auto-continuous positive airway pressure (auto-CPAP) therapy. AHI was also measured using the LT-200 in three sleep positions to evaluate the efficacy of the lateral position. AHI, ODT, and lowest Spo2 values did not differ significantly between the PSG and LT-200 recordings on the control and therapy nights. The LT-200 recordings showed that AHI, ODT, and lowest Spo2 tended to be better on the second night of auto-CPAP therapy than on the first. AHI was significantly lower in the right and left lateral sleep positions than that in the supine position. Our findings suggest that since the LT-200 device provides important information about the severity of OSAS, the efficacy of auto-CPAP therapy, and body position under unattended conditions in the home. It may prove to be a useful tool for following up patients.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_70298538</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70298538</sourcerecordid><originalsourceid>FETCH-LOGICAL-j148t-df46d9765a3d72f015053ed75de574f3df619ebb06ff875ffb7751867b7952da3</originalsourceid><addsrcrecordid>eNo1kEFLwzAYhnNQ3Jz-BcnJWyFtmn7NUYZTYeBFr5ak-aIZaVOTdGP_XmXz9MDLw3t4LsiSsQoKaKpqQa5T2jFWS8nkFVmUwKEtQS7JxyZ4Hw7FPFEbIp1UdjjmRA8uf9GgU45zn90eafKIE1XTiIqm42hiGJDOyY2fVNEpxKy0RxqxD9H8jQb3rscbcmmVT3h75oq8bx7f1s_F9vXpZf2wLXZl3ebC2LoxEhqhuIHKslIwwdGAMCigttzYppSoNWusbUFYqwFE2TagQYrKKL4i96ffKYbvGVPuBpd69F6NGObUAatkK3j7K96dxVkPaLopukHFY_dfhP8AWWVdpA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70298538</pqid></control><display><type>article</type><title>Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Open Access Titles of Japan</source><source>Alma/SFX Local Collection</source><creator>Miyata, Seiko ; Noda, Akiko ; Honda, Kumiko ; Nakata, Seiichi ; Suzuki, Keisuke ; Nakashima, Tsutomu ; Koike, Yasuo</creator><creatorcontrib>Miyata, Seiko ; Noda, Akiko ; Honda, Kumiko ; Nakata, Seiichi ; Suzuki, Keisuke ; Nakashima, Tsutomu ; Koike, Yasuo</creatorcontrib><description>A home screening device, LT-200, can record data on both breathing conditions and body positions during sleep for up to 3 consecutive days in patients with obstructive sleep apnea (OSAS). We investigated the usefulness of the LT-200 device for follow-up of OSAS. Eighteen patients (age 51.0 +/- 10.8 years, mean +/- SD) were enrolled in this study. Standard polysomnography (PSG) was performed on all patients. The number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI), the total time that nocturnal oxygen saturation was &lt; 90% (oxygen desaturation time: ODT), and the minimum oxygen saturation during sleep (lowest Spo2) were calculated. We used the LT-200 and PSG to evaluate any improvement in the data obtained after auto-continuous positive airway pressure (auto-CPAP) therapy. AHI was also measured using the LT-200 in three sleep positions to evaluate the efficacy of the lateral position. AHI, ODT, and lowest Spo2 values did not differ significantly between the PSG and LT-200 recordings on the control and therapy nights. The LT-200 recordings showed that AHI, ODT, and lowest Spo2 tended to be better on the second night of auto-CPAP therapy than on the first. AHI was significantly lower in the right and left lateral sleep positions than that in the supine position. Our findings suggest that since the LT-200 device provides important information about the severity of OSAS, the efficacy of auto-CPAP therapy, and body position under unattended conditions in the home. It may prove to be a useful tool for following up patients.</description><identifier>ISSN: 0027-7622</identifier><identifier>PMID: 17378179</identifier><language>eng</language><publisher>Japan</publisher><subject>Adult ; Continuous Positive Airway Pressure - instrumentation ; Continuous Positive Airway Pressure - methods ; Humans ; Middle Aged ; Polysomnography - instrumentation ; Polysomnography - methods ; Reproducibility of Results ; Sleep Apnea, Obstructive - pathology ; Sleep Apnea, Obstructive - physiopathology</subject><ispartof>Nagoya journal of medical science, 2007, Vol.69 (1-2), p.37-43</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,4025</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17378179$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miyata, Seiko</creatorcontrib><creatorcontrib>Noda, Akiko</creatorcontrib><creatorcontrib>Honda, Kumiko</creatorcontrib><creatorcontrib>Nakata, Seiichi</creatorcontrib><creatorcontrib>Suzuki, Keisuke</creatorcontrib><creatorcontrib>Nakashima, Tsutomu</creatorcontrib><creatorcontrib>Koike, Yasuo</creatorcontrib><title>Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device</title><title>Nagoya journal of medical science</title><addtitle>Nagoya J Med Sci</addtitle><description>A home screening device, LT-200, can record data on both breathing conditions and body positions during sleep for up to 3 consecutive days in patients with obstructive sleep apnea (OSAS). We investigated the usefulness of the LT-200 device for follow-up of OSAS. Eighteen patients (age 51.0 +/- 10.8 years, mean +/- SD) were enrolled in this study. Standard polysomnography (PSG) was performed on all patients. The number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI), the total time that nocturnal oxygen saturation was &lt; 90% (oxygen desaturation time: ODT), and the minimum oxygen saturation during sleep (lowest Spo2) were calculated. We used the LT-200 and PSG to evaluate any improvement in the data obtained after auto-continuous positive airway pressure (auto-CPAP) therapy. AHI was also measured using the LT-200 in three sleep positions to evaluate the efficacy of the lateral position. AHI, ODT, and lowest Spo2 values did not differ significantly between the PSG and LT-200 recordings on the control and therapy nights. The LT-200 recordings showed that AHI, ODT, and lowest Spo2 tended to be better on the second night of auto-CPAP therapy than on the first. AHI was significantly lower in the right and left lateral sleep positions than that in the supine position. Our findings suggest that since the LT-200 device provides important information about the severity of OSAS, the efficacy of auto-CPAP therapy, and body position under unattended conditions in the home. It may prove to be a useful tool for following up patients.</description><subject>Adult</subject><subject>Continuous Positive Airway Pressure - instrumentation</subject><subject>Continuous Positive Airway Pressure - methods</subject><subject>Humans</subject><subject>Middle Aged</subject><subject>Polysomnography - instrumentation</subject><subject>Polysomnography - methods</subject><subject>Reproducibility of Results</subject><subject>Sleep Apnea, Obstructive - pathology</subject><subject>Sleep Apnea, Obstructive - physiopathology</subject><issn>0027-7622</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1kEFLwzAYhnNQ3Jz-BcnJWyFtmn7NUYZTYeBFr5ak-aIZaVOTdGP_XmXz9MDLw3t4LsiSsQoKaKpqQa5T2jFWS8nkFVmUwKEtQS7JxyZ4Hw7FPFEbIp1UdjjmRA8uf9GgU45zn90eafKIE1XTiIqm42hiGJDOyY2fVNEpxKy0RxqxD9H8jQb3rscbcmmVT3h75oq8bx7f1s_F9vXpZf2wLXZl3ebC2LoxEhqhuIHKslIwwdGAMCigttzYppSoNWusbUFYqwFE2TagQYrKKL4i96ffKYbvGVPuBpd69F6NGObUAatkK3j7K96dxVkPaLopukHFY_dfhP8AWWVdpA</recordid><startdate>2007</startdate><enddate>2007</enddate><creator>Miyata, Seiko</creator><creator>Noda, Akiko</creator><creator>Honda, Kumiko</creator><creator>Nakata, Seiichi</creator><creator>Suzuki, Keisuke</creator><creator>Nakashima, Tsutomu</creator><creator>Koike, Yasuo</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>2007</creationdate><title>Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device</title><author>Miyata, Seiko ; Noda, Akiko ; Honda, Kumiko ; Nakata, Seiichi ; Suzuki, Keisuke ; Nakashima, Tsutomu ; Koike, Yasuo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j148t-df46d9765a3d72f015053ed75de574f3df619ebb06ff875ffb7751867b7952da3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Adult</topic><topic>Continuous Positive Airway Pressure - instrumentation</topic><topic>Continuous Positive Airway Pressure - methods</topic><topic>Humans</topic><topic>Middle Aged</topic><topic>Polysomnography - instrumentation</topic><topic>Polysomnography - methods</topic><topic>Reproducibility of Results</topic><topic>Sleep Apnea, Obstructive - pathology</topic><topic>Sleep Apnea, Obstructive - physiopathology</topic><toplevel>online_resources</toplevel><creatorcontrib>Miyata, Seiko</creatorcontrib><creatorcontrib>Noda, Akiko</creatorcontrib><creatorcontrib>Honda, Kumiko</creatorcontrib><creatorcontrib>Nakata, Seiichi</creatorcontrib><creatorcontrib>Suzuki, Keisuke</creatorcontrib><creatorcontrib>Nakashima, Tsutomu</creatorcontrib><creatorcontrib>Koike, Yasuo</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Nagoya journal of medical science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miyata, Seiko</au><au>Noda, Akiko</au><au>Honda, Kumiko</au><au>Nakata, Seiichi</au><au>Suzuki, Keisuke</au><au>Nakashima, Tsutomu</au><au>Koike, Yasuo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device</atitle><jtitle>Nagoya journal of medical science</jtitle><addtitle>Nagoya J Med Sci</addtitle><date>2007</date><risdate>2007</risdate><volume>69</volume><issue>1-2</issue><spage>37</spage><epage>43</epage><pages>37-43</pages><issn>0027-7622</issn><abstract>A home screening device, LT-200, can record data on both breathing conditions and body positions during sleep for up to 3 consecutive days in patients with obstructive sleep apnea (OSAS). We investigated the usefulness of the LT-200 device for follow-up of OSAS. Eighteen patients (age 51.0 +/- 10.8 years, mean +/- SD) were enrolled in this study. Standard polysomnography (PSG) was performed on all patients. The number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI), the total time that nocturnal oxygen saturation was &lt; 90% (oxygen desaturation time: ODT), and the minimum oxygen saturation during sleep (lowest Spo2) were calculated. We used the LT-200 and PSG to evaluate any improvement in the data obtained after auto-continuous positive airway pressure (auto-CPAP) therapy. AHI was also measured using the LT-200 in three sleep positions to evaluate the efficacy of the lateral position. AHI, ODT, and lowest Spo2 values did not differ significantly between the PSG and LT-200 recordings on the control and therapy nights. The LT-200 recordings showed that AHI, ODT, and lowest Spo2 tended to be better on the second night of auto-CPAP therapy than on the first. AHI was significantly lower in the right and left lateral sleep positions than that in the supine position. Our findings suggest that since the LT-200 device provides important information about the severity of OSAS, the efficacy of auto-CPAP therapy, and body position under unattended conditions in the home. It may prove to be a useful tool for following up patients.</abstract><cop>Japan</cop><pmid>17378179</pmid><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0027-7622
ispartof Nagoya journal of medical science, 2007, Vol.69 (1-2), p.37-43
issn 0027-7622
language eng
recordid cdi_proquest_miscellaneous_70298538
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Open Access Titles of Japan; Alma/SFX Local Collection
subjects Adult
Continuous Positive Airway Pressure - instrumentation
Continuous Positive Airway Pressure - methods
Humans
Middle Aged
Polysomnography - instrumentation
Polysomnography - methods
Reproducibility of Results
Sleep Apnea, Obstructive - pathology
Sleep Apnea, Obstructive - physiopathology
title Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T04%3A50%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Follow-up%20for%20patients%20with%20obstructive%20sleep%20apnea%20syndrome%20using%20a%20portable%20recording%20device&rft.jtitle=Nagoya%20journal%20of%20medical%20science&rft.au=Miyata,%20Seiko&rft.date=2007&rft.volume=69&rft.issue=1-2&rft.spage=37&rft.epage=43&rft.pages=37-43&rft.issn=0027-7622&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E70298538%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70298538&rft_id=info:pmid/17378179&rfr_iscdi=true