Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats

To assess the correlation between data generated by an accelerometer-based activity monitor and the distance moved in cats. Prospective experimental study. Three, four-year-old, male, purpose-bred research cats, weighing between 5.1 and 5.9 kg. Part I: Collar and harness mounted accelerometers were...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Veterinary anaesthesia and analgesia 2008-03, Vol.35 (2), p.173-183
Hauptverfasser: Lascelles, B Duncan X, Hansen, Bernard D, Thomson, Andrea, Pierce, Courtney C, Boland, Elizabeth, Smith, Eric S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 183
container_issue 2
container_start_page 173
container_title Veterinary anaesthesia and analgesia
container_volume 35
creator Lascelles, B Duncan X
Hansen, Bernard D
Thomson, Andrea
Pierce, Courtney C
Boland, Elizabeth
Smith, Eric S.
description To assess the correlation between data generated by an accelerometer-based activity monitor and the distance moved in cats. Prospective experimental study. Three, four-year-old, male, purpose-bred research cats, weighing between 5.1 and 5.9 kg. Part I: Collar and harness mounted accelerometers were evaluated in three cats, comparing simultaneously collected accelerometer data with movement data from computer-analyzed video. Part II: Cats wore collar and harness mounted accelerometers, and data were recorded for 4 weeks to evaluate day-to-day and week-to-week variation in activity. Part I: 432 hours of simultaneous video and accelerometer data were collected. The correlation between accelerometer counts and distance moved was 0.82 overall. Agreement between collar and harness mounted accelerometers was excellent with only 6% of the differences in measurements lying outside the mean difference ± 2 standard deviations. The adjusted R2 for harness accelerometer output and 6% mobility was 0.75; for movement 0.84; and for mean velocity 0.83. Evaluation of video indicated eating, grooming and scratching created high accelerometer counts with little effect on movement. Part II: There was a significant effect of day on harness (p < 0.001) and collar (p < 0.002) counts, with counts being lowest at the weekend. There was a significant effect of week on harness-mounted accelerometer counts (p < 0.034), but not on collar-mounted accelerometer counts. Harness accelerometer counts were lowest in week 1. Output from an acceleration-based digitally integrated accelerometer correlated well with distance moved and mobility in freely moving cats provided the mobility threshold in the analysis software was ≥6%. Acceleration-based activity monitors may allow for objective measurement of improved mobility following analgesic treatment for conditions such as osteoarthritis.
doi_str_mv 10.1111/j.1467-2995.2007.00367.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70297876</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1467298716307681</els_id><sourcerecordid>70297876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-4b44e77b17aef2be27c24b0f384cb015c3b9a73cc4adf673bd636aa4ed46e26a3</originalsourceid><addsrcrecordid>eNqFkEtv1DAQgC0EoqXwF5BP3BLsxLGTI1RteVQgJB4SF2vsTIqXJG5tZ7X77_E-WI5YssbyfDMef4RQzkqe1-tVyYVURdV1TVkxpkrGaqnKzSNyfko8Pp1bdUaexbhijKuuYU_JWY6Vkqo5Jw9XaxgXSM7P1A8UaO_uXIJx3FI3J7wLkLCnYC2OGPyECUNhIO7vklu7tKWTn13ygQ55p19IJ4S4BJxwTvuWfzk3UwspPidPBhgjvjjGC_Lt-urr5bvi9vPN-8s3t4UVnKVCGCFQKcMV4FAZrJSthGFD3QprGG9sbTpQtbUC-kGq2vSylgACeyGxklBfkFeHvvfBPywYk55czN8YYUa_RK1Y1alWyQy2B9AGH2PAQd8HN0HYas70Trde6Z1JvbOqd7r1Xrfe5NKXxzcWM2H_r_DoNwPFAXAx4eaUh_Bb55lVo398utG8_fJTfP_A9cfMvz3wmM2sHQYdrcPZYu8C2qR77_4_1R-KjKPU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70297876</pqid></control><display><type>article</type><title>Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Lascelles, B Duncan X ; Hansen, Bernard D ; Thomson, Andrea ; Pierce, Courtney C ; Boland, Elizabeth ; Smith, Eric S.</creator><creatorcontrib>Lascelles, B Duncan X ; Hansen, Bernard D ; Thomson, Andrea ; Pierce, Courtney C ; Boland, Elizabeth ; Smith, Eric S.</creatorcontrib><description>To assess the correlation between data generated by an accelerometer-based activity monitor and the distance moved in cats. Prospective experimental study. Three, four-year-old, male, purpose-bred research cats, weighing between 5.1 and 5.9 kg. Part I: Collar and harness mounted accelerometers were evaluated in three cats, comparing simultaneously collected accelerometer data with movement data from computer-analyzed video. Part II: Cats wore collar and harness mounted accelerometers, and data were recorded for 4 weeks to evaluate day-to-day and week-to-week variation in activity. Part I: 432 hours of simultaneous video and accelerometer data were collected. The correlation between accelerometer counts and distance moved was 0.82 overall. Agreement between collar and harness mounted accelerometers was excellent with only 6% of the differences in measurements lying outside the mean difference ± 2 standard deviations. The adjusted R2 for harness accelerometer output and 6% mobility was 0.75; for movement 0.84; and for mean velocity 0.83. Evaluation of video indicated eating, grooming and scratching created high accelerometer counts with little effect on movement. Part II: There was a significant effect of day on harness (p &lt; 0.001) and collar (p &lt; 0.002) counts, with counts being lowest at the weekend. There was a significant effect of week on harness-mounted accelerometer counts (p &lt; 0.034), but not on collar-mounted accelerometer counts. Harness accelerometer counts were lowest in week 1. Output from an acceleration-based digitally integrated accelerometer correlated well with distance moved and mobility in freely moving cats provided the mobility threshold in the analysis software was ≥6%. Acceleration-based activity monitors may allow for objective measurement of improved mobility following analgesic treatment for conditions such as osteoarthritis.</description><identifier>ISSN: 1467-2987</identifier><identifier>EISSN: 1467-2995</identifier><identifier>DOI: 10.1111/j.1467-2995.2007.00367.x</identifier><identifier>PMID: 17927675</identifier><language>eng</language><publisher>Oxford, UK: Elsevier Ltd</publisher><subject>Acceleration ; activity ; Animals ; assessment ; Cats - physiology ; feline ; Kinesiology, Applied - instrumentation ; Male ; Monitoring, Physiologic - instrumentation ; Monitoring, Physiologic - veterinary ; Motor Activity - physiology ; movement ; Prospective Studies ; video analysis ; Videotape Recording</subject><ispartof>Veterinary anaesthesia and analgesia, 2008-03, Vol.35 (2), p.173-183</ispartof><rights>2008 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-4b44e77b17aef2be27c24b0f384cb015c3b9a73cc4adf673bd636aa4ed46e26a3</citedby><cites>FETCH-LOGICAL-c410t-4b44e77b17aef2be27c24b0f384cb015c3b9a73cc4adf673bd636aa4ed46e26a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17927675$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lascelles, B Duncan X</creatorcontrib><creatorcontrib>Hansen, Bernard D</creatorcontrib><creatorcontrib>Thomson, Andrea</creatorcontrib><creatorcontrib>Pierce, Courtney C</creatorcontrib><creatorcontrib>Boland, Elizabeth</creatorcontrib><creatorcontrib>Smith, Eric S.</creatorcontrib><title>Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats</title><title>Veterinary anaesthesia and analgesia</title><addtitle>Vet Anaesth Analg</addtitle><description>To assess the correlation between data generated by an accelerometer-based activity monitor and the distance moved in cats. Prospective experimental study. Three, four-year-old, male, purpose-bred research cats, weighing between 5.1 and 5.9 kg. Part I: Collar and harness mounted accelerometers were evaluated in three cats, comparing simultaneously collected accelerometer data with movement data from computer-analyzed video. Part II: Cats wore collar and harness mounted accelerometers, and data were recorded for 4 weeks to evaluate day-to-day and week-to-week variation in activity. Part I: 432 hours of simultaneous video and accelerometer data were collected. The correlation between accelerometer counts and distance moved was 0.82 overall. Agreement between collar and harness mounted accelerometers was excellent with only 6% of the differences in measurements lying outside the mean difference ± 2 standard deviations. The adjusted R2 for harness accelerometer output and 6% mobility was 0.75; for movement 0.84; and for mean velocity 0.83. Evaluation of video indicated eating, grooming and scratching created high accelerometer counts with little effect on movement. Part II: There was a significant effect of day on harness (p &lt; 0.001) and collar (p &lt; 0.002) counts, with counts being lowest at the weekend. There was a significant effect of week on harness-mounted accelerometer counts (p &lt; 0.034), but not on collar-mounted accelerometer counts. Harness accelerometer counts were lowest in week 1. Output from an acceleration-based digitally integrated accelerometer correlated well with distance moved and mobility in freely moving cats provided the mobility threshold in the analysis software was ≥6%. Acceleration-based activity monitors may allow for objective measurement of improved mobility following analgesic treatment for conditions such as osteoarthritis.</description><subject>Acceleration</subject><subject>activity</subject><subject>Animals</subject><subject>assessment</subject><subject>Cats - physiology</subject><subject>feline</subject><subject>Kinesiology, Applied - instrumentation</subject><subject>Male</subject><subject>Monitoring, Physiologic - instrumentation</subject><subject>Monitoring, Physiologic - veterinary</subject><subject>Motor Activity - physiology</subject><subject>movement</subject><subject>Prospective Studies</subject><subject>video analysis</subject><subject>Videotape Recording</subject><issn>1467-2987</issn><issn>1467-2995</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkEtv1DAQgC0EoqXwF5BP3BLsxLGTI1RteVQgJB4SF2vsTIqXJG5tZ7X77_E-WI5YssbyfDMef4RQzkqe1-tVyYVURdV1TVkxpkrGaqnKzSNyfko8Pp1bdUaexbhijKuuYU_JWY6Vkqo5Jw9XaxgXSM7P1A8UaO_uXIJx3FI3J7wLkLCnYC2OGPyECUNhIO7vklu7tKWTn13ygQ55p19IJ4S4BJxwTvuWfzk3UwspPidPBhgjvjjGC_Lt-urr5bvi9vPN-8s3t4UVnKVCGCFQKcMV4FAZrJSthGFD3QprGG9sbTpQtbUC-kGq2vSylgACeyGxklBfkFeHvvfBPywYk55czN8YYUa_RK1Y1alWyQy2B9AGH2PAQd8HN0HYas70Trde6Z1JvbOqd7r1Xrfe5NKXxzcWM2H_r_DoNwPFAXAx4eaUh_Bb55lVo398utG8_fJTfP_A9cfMvz3wmM2sHQYdrcPZYu8C2qR77_4_1R-KjKPU</recordid><startdate>20080301</startdate><enddate>20080301</enddate><creator>Lascelles, B Duncan X</creator><creator>Hansen, Bernard D</creator><creator>Thomson, Andrea</creator><creator>Pierce, Courtney C</creator><creator>Boland, Elizabeth</creator><creator>Smith, Eric S.</creator><general>Elsevier Ltd</general><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20080301</creationdate><title>Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats</title><author>Lascelles, B Duncan X ; Hansen, Bernard D ; Thomson, Andrea ; Pierce, Courtney C ; Boland, Elizabeth ; Smith, Eric S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-4b44e77b17aef2be27c24b0f384cb015c3b9a73cc4adf673bd636aa4ed46e26a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Acceleration</topic><topic>activity</topic><topic>Animals</topic><topic>assessment</topic><topic>Cats - physiology</topic><topic>feline</topic><topic>Kinesiology, Applied - instrumentation</topic><topic>Male</topic><topic>Monitoring, Physiologic - instrumentation</topic><topic>Monitoring, Physiologic - veterinary</topic><topic>Motor Activity - physiology</topic><topic>movement</topic><topic>Prospective Studies</topic><topic>video analysis</topic><topic>Videotape Recording</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lascelles, B Duncan X</creatorcontrib><creatorcontrib>Hansen, Bernard D</creatorcontrib><creatorcontrib>Thomson, Andrea</creatorcontrib><creatorcontrib>Pierce, Courtney C</creatorcontrib><creatorcontrib>Boland, Elizabeth</creatorcontrib><creatorcontrib>Smith, Eric S.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Veterinary anaesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lascelles, B Duncan X</au><au>Hansen, Bernard D</au><au>Thomson, Andrea</au><au>Pierce, Courtney C</au><au>Boland, Elizabeth</au><au>Smith, Eric S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats</atitle><jtitle>Veterinary anaesthesia and analgesia</jtitle><addtitle>Vet Anaesth Analg</addtitle><date>2008-03-01</date><risdate>2008</risdate><volume>35</volume><issue>2</issue><spage>173</spage><epage>183</epage><pages>173-183</pages><issn>1467-2987</issn><eissn>1467-2995</eissn><abstract>To assess the correlation between data generated by an accelerometer-based activity monitor and the distance moved in cats. Prospective experimental study. Three, four-year-old, male, purpose-bred research cats, weighing between 5.1 and 5.9 kg. Part I: Collar and harness mounted accelerometers were evaluated in three cats, comparing simultaneously collected accelerometer data with movement data from computer-analyzed video. Part II: Cats wore collar and harness mounted accelerometers, and data were recorded for 4 weeks to evaluate day-to-day and week-to-week variation in activity. Part I: 432 hours of simultaneous video and accelerometer data were collected. The correlation between accelerometer counts and distance moved was 0.82 overall. Agreement between collar and harness mounted accelerometers was excellent with only 6% of the differences in measurements lying outside the mean difference ± 2 standard deviations. The adjusted R2 for harness accelerometer output and 6% mobility was 0.75; for movement 0.84; and for mean velocity 0.83. Evaluation of video indicated eating, grooming and scratching created high accelerometer counts with little effect on movement. Part II: There was a significant effect of day on harness (p &lt; 0.001) and collar (p &lt; 0.002) counts, with counts being lowest at the weekend. There was a significant effect of week on harness-mounted accelerometer counts (p &lt; 0.034), but not on collar-mounted accelerometer counts. Harness accelerometer counts were lowest in week 1. Output from an acceleration-based digitally integrated accelerometer correlated well with distance moved and mobility in freely moving cats provided the mobility threshold in the analysis software was ≥6%. Acceleration-based activity monitors may allow for objective measurement of improved mobility following analgesic treatment for conditions such as osteoarthritis.</abstract><cop>Oxford, UK</cop><pub>Elsevier Ltd</pub><pmid>17927675</pmid><doi>10.1111/j.1467-2995.2007.00367.x</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1467-2987
ispartof Veterinary anaesthesia and analgesia, 2008-03, Vol.35 (2), p.173-183
issn 1467-2987
1467-2995
language eng
recordid cdi_proquest_miscellaneous_70297876
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Acceleration
activity
Animals
assessment
Cats - physiology
feline
Kinesiology, Applied - instrumentation
Male
Monitoring, Physiologic - instrumentation
Monitoring, Physiologic - veterinary
Motor Activity - physiology
movement
Prospective Studies
video analysis
Videotape Recording
title Evaluation of a digitally integrated accelerometer-based activity monitor for the measurement of activity in cats
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T15%3A14%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20digitally%20integrated%20accelerometer-based%20activity%20monitor%20for%20the%20measurement%20of%20activity%20in%20cats&rft.jtitle=Veterinary%20anaesthesia%20and%20analgesia&rft.au=Lascelles,%20B%20Duncan%20X&rft.date=2008-03-01&rft.volume=35&rft.issue=2&rft.spage=173&rft.epage=183&rft.pages=173-183&rft.issn=1467-2987&rft.eissn=1467-2995&rft_id=info:doi/10.1111/j.1467-2995.2007.00367.x&rft_dat=%3Cproquest_cross%3E70297876%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70297876&rft_id=info:pmid/17927675&rft_els_id=S1467298716307681&rfr_iscdi=true