Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control
1 Laboratory of Systems Physiology, Division of Basic Sciences, Medical School, University of Crete; and 2 Computational Neuroscience Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas, Heraklion, Crete, Greece Submitted 27 March 2007; accepted i...
Gespeichert in:
Veröffentlicht in: | Journal of neurophysiology 2008-02, Vol.99 (2), p.473-483 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 483 |
---|---|
container_issue | 2 |
container_start_page | 473 |
container_title | Journal of neurophysiology |
container_volume | 99 |
creator | Erimaki, Sophia Christakos, Constantinos N |
description | 1 Laboratory of Systems Physiology, Division of Basic Sciences, Medical School, University of Crete; and 2 Computational Neuroscience Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas, Heraklion, Crete, Greece
Submitted 27 March 2007;
accepted in final form 3 December 2007
In quasi-sinusoidal (0.5–3.0 Hz) voluntary muscle contractions, we studied the 6- to 10-Hz motor unit (MU) firing synchrony and muscle force oscillation with emphasis on their neural substrate and relation to rhythmical motor control. Our analyses were performed on data from 121 contractions of a finger muscle in 24 human subjects. They demonstrate that coherent 6- to 10-Hz components of MU discharges coexist with carrier components and coherent modulation components underlying the voluntary force variations. The 6- to 10-Hz synchrony has the frequency of the tremor synchrony in steady contractions and is also widespread and in-phase. Its strength ranges from very small to very large (MU/MU coherence >0.50) among contractions; moreover, it is not related to the contraction parameters, in accord with the notion of a distinct 6- to 10-Hz synaptic input to the MUs. Unlike the coherent MU modulations and the voluntary force variations, the in-phase 6- to 10-Hz MU components are suppressed or even eliminated during ischemia, while the respective force component is drastically reduced. These findings agree with the widely assumed supraspinal origin of the MU modulations, but they also strongly suggest a key role for muscle spindle feedback in the generation of the 6- to 10-Hz synaptic input. They therefore provide important information for the study of generators of the 6- to 10-Hz rhythm which subserves the postulated rhythmical control and is manifested as force and movement components. Moreover, they argue for a participation of oscillating spinal stretch reflex loops in the rhythm generation, possibly in interaction with supraspinal oscillators.
Address for reprint requests and other correspondence: C. N. Christakos, Division of Basic Sciences, Medical School, University of Crete, 71003 Heraklion, Crete, Greece (E-mail: ccnncc{at}med.uoc.gr ) |
doi_str_mv | 10.1152/jn.00341.2007 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_70295779</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70295779</sourcerecordid><originalsourceid>FETCH-LOGICAL-c462t-6c94dd7e0314425c2a610de141dccebb4fa91823be1ca06ec009256be2c9fa663</originalsourceid><addsrcrecordid>eNqFkU1vEzEQhi0EomnLkSvyiduGsfcryw2FfiA1VIrSXi2vdzbryGsH2ysa_gv_ld00qCfEyR7P875jzUvIewZzxnL-aWfnAGnG5hygfEVm4xtPWF4tXpMZwHhPoSzPyHkIOxiJHPhbcsYWkJeMZTPye-k69GgjXbnoPH2wOtJ1d4hdH6i2NHZIi4QBvf1F19JukX4dvLZbutE9Jo_SH6bi0ZnBxrGgqyEog3TpbPRSRe1s-Ey_4-CloStUnbQ69FTahq7RyKlPozsN1GqCjt846p25JG9aaQK-O50X5OH6arO8Te7ub74tv9wlKit4TApVZU1TIqQsy3iuuCwYNMgy1iiFdZ21smILntbIlIQCFUDF86JGrqpWFkV6QT4---69-zFgiKLXQaEx0qIbgiiBV3lZVv8FOeQpMJjA5BlU3oXgsRV7r_txQ4KBmIITOyuOwYkpuJH_cDIe6h6bF_qU1MvkTm-7n9qj2HeHoJ1x28PkVVWCi6xMR5D_G7wejNngUxwVfwVi37TpHzDvtSo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20530109</pqid></control><display><type>article</type><title>Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control</title><source>MEDLINE</source><source>American Physiological Society</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Erimaki, Sophia ; Christakos, Constantinos N</creator><creatorcontrib>Erimaki, Sophia ; Christakos, Constantinos N</creatorcontrib><description>1 Laboratory of Systems Physiology, Division of Basic Sciences, Medical School, University of Crete; and 2 Computational Neuroscience Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas, Heraklion, Crete, Greece
Submitted 27 March 2007;
accepted in final form 3 December 2007
In quasi-sinusoidal (0.5–3.0 Hz) voluntary muscle contractions, we studied the 6- to 10-Hz motor unit (MU) firing synchrony and muscle force oscillation with emphasis on their neural substrate and relation to rhythmical motor control. Our analyses were performed on data from 121 contractions of a finger muscle in 24 human subjects. They demonstrate that coherent 6- to 10-Hz components of MU discharges coexist with carrier components and coherent modulation components underlying the voluntary force variations. The 6- to 10-Hz synchrony has the frequency of the tremor synchrony in steady contractions and is also widespread and in-phase. Its strength ranges from very small to very large (MU/MU coherence >0.50) among contractions; moreover, it is not related to the contraction parameters, in accord with the notion of a distinct 6- to 10-Hz synaptic input to the MUs. Unlike the coherent MU modulations and the voluntary force variations, the in-phase 6- to 10-Hz MU components are suppressed or even eliminated during ischemia, while the respective force component is drastically reduced. These findings agree with the widely assumed supraspinal origin of the MU modulations, but they also strongly suggest a key role for muscle spindle feedback in the generation of the 6- to 10-Hz synaptic input. They therefore provide important information for the study of generators of the 6- to 10-Hz rhythm which subserves the postulated rhythmical control and is manifested as force and movement components. Moreover, they argue for a participation of oscillating spinal stretch reflex loops in the rhythm generation, possibly in interaction with supraspinal oscillators.
Address for reprint requests and other correspondence: C. N. Christakos, Division of Basic Sciences, Medical School, University of Crete, 71003 Heraklion, Crete, Greece (E-mail: ccnncc{at}med.uoc.gr )</description><identifier>ISSN: 0022-3077</identifier><identifier>EISSN: 1522-1598</identifier><identifier>DOI: 10.1152/jn.00341.2007</identifier><identifier>PMID: 18057114</identifier><language>eng</language><publisher>United States: Am Phys Soc</publisher><subject>Action Potentials - physiology ; Adult ; Analysis of Variance ; Electromyography - methods ; Humans ; Ischemia - physiopathology ; Middle Aged ; Motor Neurons - physiology ; Muscle Contraction - physiology ; Muscle, Skeletal - cytology ; Periodicity ; Recruitment, Neurophysiological ; Spectrum Analysis ; Time Factors</subject><ispartof>Journal of neurophysiology, 2008-02, Vol.99 (2), p.473-483</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c462t-6c94dd7e0314425c2a610de141dccebb4fa91823be1ca06ec009256be2c9fa663</citedby><cites>FETCH-LOGICAL-c462t-6c94dd7e0314425c2a610de141dccebb4fa91823be1ca06ec009256be2c9fa663</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,3026,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18057114$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Erimaki, Sophia</creatorcontrib><creatorcontrib>Christakos, Constantinos N</creatorcontrib><title>Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control</title><title>Journal of neurophysiology</title><addtitle>J Neurophysiol</addtitle><description>1 Laboratory of Systems Physiology, Division of Basic Sciences, Medical School, University of Crete; and 2 Computational Neuroscience Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas, Heraklion, Crete, Greece
Submitted 27 March 2007;
accepted in final form 3 December 2007
In quasi-sinusoidal (0.5–3.0 Hz) voluntary muscle contractions, we studied the 6- to 10-Hz motor unit (MU) firing synchrony and muscle force oscillation with emphasis on their neural substrate and relation to rhythmical motor control. Our analyses were performed on data from 121 contractions of a finger muscle in 24 human subjects. They demonstrate that coherent 6- to 10-Hz components of MU discharges coexist with carrier components and coherent modulation components underlying the voluntary force variations. The 6- to 10-Hz synchrony has the frequency of the tremor synchrony in steady contractions and is also widespread and in-phase. Its strength ranges from very small to very large (MU/MU coherence >0.50) among contractions; moreover, it is not related to the contraction parameters, in accord with the notion of a distinct 6- to 10-Hz synaptic input to the MUs. Unlike the coherent MU modulations and the voluntary force variations, the in-phase 6- to 10-Hz MU components are suppressed or even eliminated during ischemia, while the respective force component is drastically reduced. These findings agree with the widely assumed supraspinal origin of the MU modulations, but they also strongly suggest a key role for muscle spindle feedback in the generation of the 6- to 10-Hz synaptic input. They therefore provide important information for the study of generators of the 6- to 10-Hz rhythm which subserves the postulated rhythmical control and is manifested as force and movement components. Moreover, they argue for a participation of oscillating spinal stretch reflex loops in the rhythm generation, possibly in interaction with supraspinal oscillators.
Address for reprint requests and other correspondence: C. N. Christakos, Division of Basic Sciences, Medical School, University of Crete, 71003 Heraklion, Crete, Greece (E-mail: ccnncc{at}med.uoc.gr )</description><subject>Action Potentials - physiology</subject><subject>Adult</subject><subject>Analysis of Variance</subject><subject>Electromyography - methods</subject><subject>Humans</subject><subject>Ischemia - physiopathology</subject><subject>Middle Aged</subject><subject>Motor Neurons - physiology</subject><subject>Muscle Contraction - physiology</subject><subject>Muscle, Skeletal - cytology</subject><subject>Periodicity</subject><subject>Recruitment, Neurophysiological</subject><subject>Spectrum Analysis</subject><subject>Time Factors</subject><issn>0022-3077</issn><issn>1522-1598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1vEzEQhi0EomnLkSvyiduGsfcryw2FfiA1VIrSXi2vdzbryGsH2ysa_gv_ld00qCfEyR7P875jzUvIewZzxnL-aWfnAGnG5hygfEVm4xtPWF4tXpMZwHhPoSzPyHkIOxiJHPhbcsYWkJeMZTPye-k69GgjXbnoPH2wOtJ1d4hdH6i2NHZIi4QBvf1F19JukX4dvLZbutE9Jo_SH6bi0ZnBxrGgqyEog3TpbPRSRe1s-Ey_4-CloStUnbQ69FTahq7RyKlPozsN1GqCjt846p25JG9aaQK-O50X5OH6arO8Te7ub74tv9wlKit4TApVZU1TIqQsy3iuuCwYNMgy1iiFdZ21smILntbIlIQCFUDF86JGrqpWFkV6QT4---69-zFgiKLXQaEx0qIbgiiBV3lZVv8FOeQpMJjA5BlU3oXgsRV7r_txQ4KBmIITOyuOwYkpuJH_cDIe6h6bF_qU1MvkTm-7n9qj2HeHoJ1x28PkVVWCi6xMR5D_G7wejNngUxwVfwVi37TpHzDvtSo</recordid><startdate>20080201</startdate><enddate>20080201</enddate><creator>Erimaki, Sophia</creator><creator>Christakos, Constantinos N</creator><general>Am Phys Soc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>7X8</scope></search><sort><creationdate>20080201</creationdate><title>Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control</title><author>Erimaki, Sophia ; Christakos, Constantinos N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c462t-6c94dd7e0314425c2a610de141dccebb4fa91823be1ca06ec009256be2c9fa663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Action Potentials - physiology</topic><topic>Adult</topic><topic>Analysis of Variance</topic><topic>Electromyography - methods</topic><topic>Humans</topic><topic>Ischemia - physiopathology</topic><topic>Middle Aged</topic><topic>Motor Neurons - physiology</topic><topic>Muscle Contraction - physiology</topic><topic>Muscle, Skeletal - cytology</topic><topic>Periodicity</topic><topic>Recruitment, Neurophysiological</topic><topic>Spectrum Analysis</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Erimaki, Sophia</creatorcontrib><creatorcontrib>Christakos, Constantinos N</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neurophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Erimaki, Sophia</au><au>Christakos, Constantinos N</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control</atitle><jtitle>Journal of neurophysiology</jtitle><addtitle>J Neurophysiol</addtitle><date>2008-02-01</date><risdate>2008</risdate><volume>99</volume><issue>2</issue><spage>473</spage><epage>483</epage><pages>473-483</pages><issn>0022-3077</issn><eissn>1522-1598</eissn><abstract>1 Laboratory of Systems Physiology, Division of Basic Sciences, Medical School, University of Crete; and 2 Computational Neuroscience Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas, Heraklion, Crete, Greece
Submitted 27 March 2007;
accepted in final form 3 December 2007
In quasi-sinusoidal (0.5–3.0 Hz) voluntary muscle contractions, we studied the 6- to 10-Hz motor unit (MU) firing synchrony and muscle force oscillation with emphasis on their neural substrate and relation to rhythmical motor control. Our analyses were performed on data from 121 contractions of a finger muscle in 24 human subjects. They demonstrate that coherent 6- to 10-Hz components of MU discharges coexist with carrier components and coherent modulation components underlying the voluntary force variations. The 6- to 10-Hz synchrony has the frequency of the tremor synchrony in steady contractions and is also widespread and in-phase. Its strength ranges from very small to very large (MU/MU coherence >0.50) among contractions; moreover, it is not related to the contraction parameters, in accord with the notion of a distinct 6- to 10-Hz synaptic input to the MUs. Unlike the coherent MU modulations and the voluntary force variations, the in-phase 6- to 10-Hz MU components are suppressed or even eliminated during ischemia, while the respective force component is drastically reduced. These findings agree with the widely assumed supraspinal origin of the MU modulations, but they also strongly suggest a key role for muscle spindle feedback in the generation of the 6- to 10-Hz synaptic input. They therefore provide important information for the study of generators of the 6- to 10-Hz rhythm which subserves the postulated rhythmical control and is manifested as force and movement components. Moreover, they argue for a participation of oscillating spinal stretch reflex loops in the rhythm generation, possibly in interaction with supraspinal oscillators.
Address for reprint requests and other correspondence: C. N. Christakos, Division of Basic Sciences, Medical School, University of Crete, 71003 Heraklion, Crete, Greece (E-mail: ccnncc{at}med.uoc.gr )</abstract><cop>United States</cop><pub>Am Phys Soc</pub><pmid>18057114</pmid><doi>10.1152/jn.00341.2007</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3077 |
ispartof | Journal of neurophysiology, 2008-02, Vol.99 (2), p.473-483 |
issn | 0022-3077 1522-1598 |
language | eng |
recordid | cdi_proquest_miscellaneous_70295779 |
source | MEDLINE; American Physiological Society; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Action Potentials - physiology Adult Analysis of Variance Electromyography - methods Humans Ischemia - physiopathology Middle Aged Motor Neurons - physiology Muscle Contraction - physiology Muscle, Skeletal - cytology Periodicity Recruitment, Neurophysiological Spectrum Analysis Time Factors |
title | Coherent Motor Unit Rhythms in the 6-10 Hz Range During Time-Varying Voluntary Muscle Contractions: Neural Mechanism and Relation to Rhythmical Motor Control |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T19%3A22%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coherent%20Motor%20Unit%20Rhythms%20in%20the%206-10%20Hz%20Range%20During%20Time-Varying%20Voluntary%20Muscle%20Contractions:%20Neural%20Mechanism%20and%20Relation%20to%20Rhythmical%20Motor%20Control&rft.jtitle=Journal%20of%20neurophysiology&rft.au=Erimaki,%20Sophia&rft.date=2008-02-01&rft.volume=99&rft.issue=2&rft.spage=473&rft.epage=483&rft.pages=473-483&rft.issn=0022-3077&rft.eissn=1522-1598&rft_id=info:doi/10.1152/jn.00341.2007&rft_dat=%3Cproquest_pubme%3E70295779%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20530109&rft_id=info:pmid/18057114&rfr_iscdi=true |