A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy

Introduction: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. Methods and Results: We designed a hybrid s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiovascular electrophysiology 2008-02, Vol.19 (2), p.188-193
Hauptverfasser: KHAIRY, PAUL, CARTIER, CATHERINE, CHAUVET, PATRICK, TANGUAY, JEAN-FRANÇOIS, SIMÉON, BERTIN, LALONDE, JEAN-PIERRE, DUBUC, MARC
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 193
container_issue 2
container_start_page 188
container_title Journal of cardiovascular electrophysiology
container_volume 19
creator KHAIRY, PAUL
CARTIER, CATHERINE
CHAUVET, PATRICK
TANGUAY, JEAN-FRANÇOIS
SIMÉON, BERTIN
LALONDE, JEAN-PIERRE
DUBUC, MARC
description Introduction: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. Methods and Results: We designed a hybrid steerable catheter capable of delivering RF and cryoenergy independently, sequentially, and simultaneously. The novel catheter system was tested pre‐clinically by creating a total of 180 ablation lesions in 20 mongrel dogs. Right atrial and right and left ventricular sites were preselected by a randomized factorial design devised to compare sequential and simultaneous RF and cryoenergy applications to standard RF, irrigated RF, and standard cryoablation. A steerable 4‐mm electrode‐tip hybrid catheter (“Fire and Ice”) was created by modifying a 7 F cryocatheter (Freezor™, CryoCath Technologies, Montreal, Canada). RF energy was injected via a copper wire, thermocouples were isolated to reduce RF interference, and 100 KHz band pass filters and RF chokes were added. Sequential low‐dose RF (20 W, 60 seconds) preceding or following cryoablation resulted in larger lesions (P = 0.0010). The addition of RF energy did, however, produce more thrombus than cryoenergy alone, with clot detected on 82.4% versus 12.1% of ablation lesions, P < 0.0001. Simultaneously applying the two energy modalities (45 W, 10 or 30°C, 60 seconds) created more voluminous lesions than standard RF ablation (median 288.1 vs 126.1 mm3, P = 0.0333) of similar dimension to irrigated RF ablation. Conclusion: A versatile catheter system was fashioned capable of creating standard cryoablation lesions, standard RF lesions, and simultaneous lesions of similar dimension to irrigated RF.
doi_str_mv 10.1111/j.1540-8167.2007.00997.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70276855</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70276855</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4047-81585a60c0b5ebfc3bf7bcf972cb0b0d17f434a54c8ef54c738fa74be9b225d83</originalsourceid><addsrcrecordid>eNqNkE1v1DAQhi0EoqXwF5BP3BLGsR0nEpdV1A9QVQQsKuJi2c6YZslHa2dh8-_xsqtyxQd7JL_PzOghhDLIWTpvNzmTArKKlSovAFQOUNcq3z0hp48fT1MNQma8UvyEvIhxA8B4CfI5OWGqVowJfkq-rejN9At7erXY0LV0HcwYnZnvcMZAV7Y3czeN9MsSZxzo-s7MtJkG240Y6WfTdpMP-LDF0S3UjC1twjLhiOHH8pI886aP-Or4npGvF-fr5iq7_nj5vlldZ06AUGlTWUlTggMr0XrHrVfW-VoVzoKFlikvuDBSuAp9uhWvvFHCYm2LQrYVPyNvDn3vw5QWibMeuuiw782I0zZqBYUqKylTsDoEXZhiDOj1fegGExbNQO-t6o3ey9N7eXpvVf-1qncJfX2csbUDtv_Ao8YUeHcI_O56XP67sf7QnKci4dkB75Ll3SNuwk9dKq6kvr251J_qori4he-64X8A_vyVsA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70276855</pqid></control><display><type>article</type><title>A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>KHAIRY, PAUL ; CARTIER, CATHERINE ; CHAUVET, PATRICK ; TANGUAY, JEAN-FRANÇOIS ; SIMÉON, BERTIN ; LALONDE, JEAN-PIERRE ; DUBUC, MARC</creator><creatorcontrib>KHAIRY, PAUL ; CARTIER, CATHERINE ; CHAUVET, PATRICK ; TANGUAY, JEAN-FRANÇOIS ; SIMÉON, BERTIN ; LALONDE, JEAN-PIERRE ; DUBUC, MARC</creatorcontrib><description>Introduction: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. Methods and Results: We designed a hybrid steerable catheter capable of delivering RF and cryoenergy independently, sequentially, and simultaneously. The novel catheter system was tested pre‐clinically by creating a total of 180 ablation lesions in 20 mongrel dogs. Right atrial and right and left ventricular sites were preselected by a randomized factorial design devised to compare sequential and simultaneous RF and cryoenergy applications to standard RF, irrigated RF, and standard cryoablation. A steerable 4‐mm electrode‐tip hybrid catheter (“Fire and Ice”) was created by modifying a 7 F cryocatheter (Freezor™, CryoCath Technologies, Montreal, Canada). RF energy was injected via a copper wire, thermocouples were isolated to reduce RF interference, and 100 KHz band pass filters and RF chokes were added. Sequential low‐dose RF (20 W, 60 seconds) preceding or following cryoablation resulted in larger lesions (P = 0.0010). The addition of RF energy did, however, produce more thrombus than cryoenergy alone, with clot detected on 82.4% versus 12.1% of ablation lesions, P &lt; 0.0001. Simultaneously applying the two energy modalities (45 W, 10 or 30°C, 60 seconds) created more voluminous lesions than standard RF ablation (median 288.1 vs 126.1 mm3, P = 0.0333) of similar dimension to irrigated RF ablation. Conclusion: A versatile catheter system was fashioned capable of creating standard cryoablation lesions, standard RF lesions, and simultaneous lesions of similar dimension to irrigated RF.</description><identifier>ISSN: 1045-3873</identifier><identifier>EISSN: 1540-8167</identifier><identifier>DOI: 10.1111/j.1540-8167.2007.00997.x</identifier><identifier>PMID: 17971143</identifier><language>eng</language><publisher>Malden, USA: Blackwell Publishing Inc</publisher><subject>Animals ; Catheter Ablation - instrumentation ; Catheter Ablation - methods ; Catheter Ablation - trends ; cryoablation ; cryoenergy ; Cryosurgery - instrumentation ; Cryosurgery - methods ; Cryosurgery - trends ; Dogs ; Equipment Design - instrumentation ; Equipment Design - methods ; Equipment Design - trends ; irrigated radiofrequency ablation ; Myocardium - pathology ; radiofrequency ablation ; thrombus</subject><ispartof>Journal of cardiovascular electrophysiology, 2008-02, Vol.19 (2), p.188-193</ispartof><rights>2007 by Futura Publishing Company, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4047-81585a60c0b5ebfc3bf7bcf972cb0b0d17f434a54c8ef54c738fa74be9b225d83</citedby><cites>FETCH-LOGICAL-c4047-81585a60c0b5ebfc3bf7bcf972cb0b0d17f434a54c8ef54c738fa74be9b225d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1540-8167.2007.00997.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1540-8167.2007.00997.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17971143$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KHAIRY, PAUL</creatorcontrib><creatorcontrib>CARTIER, CATHERINE</creatorcontrib><creatorcontrib>CHAUVET, PATRICK</creatorcontrib><creatorcontrib>TANGUAY, JEAN-FRANÇOIS</creatorcontrib><creatorcontrib>SIMÉON, BERTIN</creatorcontrib><creatorcontrib>LALONDE, JEAN-PIERRE</creatorcontrib><creatorcontrib>DUBUC, MARC</creatorcontrib><title>A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy</title><title>Journal of cardiovascular electrophysiology</title><addtitle>J Cardiovasc Electrophysiol</addtitle><description>Introduction: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. Methods and Results: We designed a hybrid steerable catheter capable of delivering RF and cryoenergy independently, sequentially, and simultaneously. The novel catheter system was tested pre‐clinically by creating a total of 180 ablation lesions in 20 mongrel dogs. Right atrial and right and left ventricular sites were preselected by a randomized factorial design devised to compare sequential and simultaneous RF and cryoenergy applications to standard RF, irrigated RF, and standard cryoablation. A steerable 4‐mm electrode‐tip hybrid catheter (“Fire and Ice”) was created by modifying a 7 F cryocatheter (Freezor™, CryoCath Technologies, Montreal, Canada). RF energy was injected via a copper wire, thermocouples were isolated to reduce RF interference, and 100 KHz band pass filters and RF chokes were added. Sequential low‐dose RF (20 W, 60 seconds) preceding or following cryoablation resulted in larger lesions (P = 0.0010). The addition of RF energy did, however, produce more thrombus than cryoenergy alone, with clot detected on 82.4% versus 12.1% of ablation lesions, P &lt; 0.0001. Simultaneously applying the two energy modalities (45 W, 10 or 30°C, 60 seconds) created more voluminous lesions than standard RF ablation (median 288.1 vs 126.1 mm3, P = 0.0333) of similar dimension to irrigated RF ablation. Conclusion: A versatile catheter system was fashioned capable of creating standard cryoablation lesions, standard RF lesions, and simultaneous lesions of similar dimension to irrigated RF.</description><subject>Animals</subject><subject>Catheter Ablation - instrumentation</subject><subject>Catheter Ablation - methods</subject><subject>Catheter Ablation - trends</subject><subject>cryoablation</subject><subject>cryoenergy</subject><subject>Cryosurgery - instrumentation</subject><subject>Cryosurgery - methods</subject><subject>Cryosurgery - trends</subject><subject>Dogs</subject><subject>Equipment Design - instrumentation</subject><subject>Equipment Design - methods</subject><subject>Equipment Design - trends</subject><subject>irrigated radiofrequency ablation</subject><subject>Myocardium - pathology</subject><subject>radiofrequency ablation</subject><subject>thrombus</subject><issn>1045-3873</issn><issn>1540-8167</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkE1v1DAQhi0EoqXwF5BP3BLGsR0nEpdV1A9QVQQsKuJi2c6YZslHa2dh8-_xsqtyxQd7JL_PzOghhDLIWTpvNzmTArKKlSovAFQOUNcq3z0hp48fT1MNQma8UvyEvIhxA8B4CfI5OWGqVowJfkq-rejN9At7erXY0LV0HcwYnZnvcMZAV7Y3czeN9MsSZxzo-s7MtJkG240Y6WfTdpMP-LDF0S3UjC1twjLhiOHH8pI886aP-Or4npGvF-fr5iq7_nj5vlldZ06AUGlTWUlTggMr0XrHrVfW-VoVzoKFlikvuDBSuAp9uhWvvFHCYm2LQrYVPyNvDn3vw5QWibMeuuiw782I0zZqBYUqKylTsDoEXZhiDOj1fegGExbNQO-t6o3ey9N7eXpvVf-1qncJfX2csbUDtv_Ao8YUeHcI_O56XP67sf7QnKci4dkB75Ll3SNuwk9dKq6kvr251J_qori4he-64X8A_vyVsA</recordid><startdate>200802</startdate><enddate>200802</enddate><creator>KHAIRY, PAUL</creator><creator>CARTIER, CATHERINE</creator><creator>CHAUVET, PATRICK</creator><creator>TANGUAY, JEAN-FRANÇOIS</creator><creator>SIMÉON, BERTIN</creator><creator>LALONDE, JEAN-PIERRE</creator><creator>DUBUC, MARC</creator><general>Blackwell Publishing Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200802</creationdate><title>A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy</title><author>KHAIRY, PAUL ; CARTIER, CATHERINE ; CHAUVET, PATRICK ; TANGUAY, JEAN-FRANÇOIS ; SIMÉON, BERTIN ; LALONDE, JEAN-PIERRE ; DUBUC, MARC</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4047-81585a60c0b5ebfc3bf7bcf972cb0b0d17f434a54c8ef54c738fa74be9b225d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Animals</topic><topic>Catheter Ablation - instrumentation</topic><topic>Catheter Ablation - methods</topic><topic>Catheter Ablation - trends</topic><topic>cryoablation</topic><topic>cryoenergy</topic><topic>Cryosurgery - instrumentation</topic><topic>Cryosurgery - methods</topic><topic>Cryosurgery - trends</topic><topic>Dogs</topic><topic>Equipment Design - instrumentation</topic><topic>Equipment Design - methods</topic><topic>Equipment Design - trends</topic><topic>irrigated radiofrequency ablation</topic><topic>Myocardium - pathology</topic><topic>radiofrequency ablation</topic><topic>thrombus</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KHAIRY, PAUL</creatorcontrib><creatorcontrib>CARTIER, CATHERINE</creatorcontrib><creatorcontrib>CHAUVET, PATRICK</creatorcontrib><creatorcontrib>TANGUAY, JEAN-FRANÇOIS</creatorcontrib><creatorcontrib>SIMÉON, BERTIN</creatorcontrib><creatorcontrib>LALONDE, JEAN-PIERRE</creatorcontrib><creatorcontrib>DUBUC, MARC</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cardiovascular electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KHAIRY, PAUL</au><au>CARTIER, CATHERINE</au><au>CHAUVET, PATRICK</au><au>TANGUAY, JEAN-FRANÇOIS</au><au>SIMÉON, BERTIN</au><au>LALONDE, JEAN-PIERRE</au><au>DUBUC, MARC</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy</atitle><jtitle>Journal of cardiovascular electrophysiology</jtitle><addtitle>J Cardiovasc Electrophysiol</addtitle><date>2008-02</date><risdate>2008</risdate><volume>19</volume><issue>2</issue><spage>188</spage><epage>193</epage><pages>188-193</pages><issn>1045-3873</issn><eissn>1540-8167</eissn><abstract>Introduction: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. Methods and Results: We designed a hybrid steerable catheter capable of delivering RF and cryoenergy independently, sequentially, and simultaneously. The novel catheter system was tested pre‐clinically by creating a total of 180 ablation lesions in 20 mongrel dogs. Right atrial and right and left ventricular sites were preselected by a randomized factorial design devised to compare sequential and simultaneous RF and cryoenergy applications to standard RF, irrigated RF, and standard cryoablation. A steerable 4‐mm electrode‐tip hybrid catheter (“Fire and Ice”) was created by modifying a 7 F cryocatheter (Freezor™, CryoCath Technologies, Montreal, Canada). RF energy was injected via a copper wire, thermocouples were isolated to reduce RF interference, and 100 KHz band pass filters and RF chokes were added. Sequential low‐dose RF (20 W, 60 seconds) preceding or following cryoablation resulted in larger lesions (P = 0.0010). The addition of RF energy did, however, produce more thrombus than cryoenergy alone, with clot detected on 82.4% versus 12.1% of ablation lesions, P &lt; 0.0001. Simultaneously applying the two energy modalities (45 W, 10 or 30°C, 60 seconds) created more voluminous lesions than standard RF ablation (median 288.1 vs 126.1 mm3, P = 0.0333) of similar dimension to irrigated RF ablation. Conclusion: A versatile catheter system was fashioned capable of creating standard cryoablation lesions, standard RF lesions, and simultaneous lesions of similar dimension to irrigated RF.</abstract><cop>Malden, USA</cop><pub>Blackwell Publishing Inc</pub><pmid>17971143</pmid><doi>10.1111/j.1540-8167.2007.00997.x</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1045-3873
ispartof Journal of cardiovascular electrophysiology, 2008-02, Vol.19 (2), p.188-193
issn 1045-3873
1540-8167
language eng
recordid cdi_proquest_miscellaneous_70276855
source MEDLINE; Wiley Online Library All Journals
subjects Animals
Catheter Ablation - instrumentation
Catheter Ablation - methods
Catheter Ablation - trends
cryoablation
cryoenergy
Cryosurgery - instrumentation
Cryosurgery - methods
Cryosurgery - trends
Dogs
Equipment Design - instrumentation
Equipment Design - methods
Equipment Design - trends
irrigated radiofrequency ablation
Myocardium - pathology
radiofrequency ablation
thrombus
title A Novel Hybrid Transcatheter Ablation System That Combines Radiofrequency and Cryoenergy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T13%3A41%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Novel%20Hybrid%20Transcatheter%20Ablation%20System%20That%20Combines%20Radiofrequency%20and%20Cryoenergy&rft.jtitle=Journal%20of%20cardiovascular%20electrophysiology&rft.au=KHAIRY,%20PAUL&rft.date=2008-02&rft.volume=19&rft.issue=2&rft.spage=188&rft.epage=193&rft.pages=188-193&rft.issn=1045-3873&rft.eissn=1540-8167&rft_id=info:doi/10.1111/j.1540-8167.2007.00997.x&rft_dat=%3Cproquest_cross%3E70276855%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70276855&rft_id=info:pmid/17971143&rfr_iscdi=true