Evaluation of a new, fully automated immunoassay for detection of HTLV-I and HTLV-II antibodies

Screening blood donations for human T-lymphotropic virus types I and II (HTLV-I/II) continues to be important in protecting the safety of blood products and controlling the global spread of these retroviruses. We have developed a fully automated, third generation chemiluminescent immunoassay, ARCHIT...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of medical virology 2008-03, Vol.80 (3), p.484-493
Hauptverfasser: Qiu, Xiaoxing, Hodges, Steven, Lukaszewska, Teresa, Hino, Shigeo, Arai, Hiroyasu, Yamaguchi, Julie, Swanson, Priscilla, Schochetman, Gerald, Devare, Sushil G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Screening blood donations for human T-lymphotropic virus types I and II (HTLV-I/II) continues to be important in protecting the safety of blood products and controlling the global spread of these retroviruses. We have developed a fully automated, third generation chemiluminescent immunoassay, ARCHITECT rHTLV-I/II, for detection of antibodies to HTLV-I/II. The assay utilizes recombinant proteins and synthetic peptides and is configured in a double antigen sandwich assay format. Specificity of the assay was 99.98% (9,254/9,256, 95% CI = 99.92-100%) with the negative specimens from the general population including blood donors, hospital patients and pregnant women from the US, Japan and Nicaragua. The assay demonstrated 100% sensitivity by detecting 498 specimens from individuals infected with HTLV-I (n = 385) and HTLV-II (n = 113). ARCHITECT rHTLV-I/II results were in complete agreement with the Murex HTLV-I/II reference assay and 99.7% agreement with the Genelabs HTLV Blot 2.4 confirmatory assay. Analytical sensitivity of the assay was equivalent to Murex HTLV-I/II assay based on end point dilutions. Furthermore, using a panel of 397 specimens from Japan, the ARCHITECT rHTLV-I/II assay exhibited distinct discrimination between the antibody negative (Delta Value = -7.6) and positive (Delta Value = 7.6) populations. Based on the excellent specificity and sensitivity, the new ARCHITECT rHTLV-I/II assay should be an effective test for the diagnosis of HTLV-I/II infection and also for blood donor screening. J. Med. Virol. 80:484-493, 2008. © 2008 Wiley-Liss, Inc.
ISSN:0146-6615
1096-9071
DOI:10.1002/jmv.21083