Respiratory effect of prolonged electrical weapon application on human volunteers

Conducted electrical weapons (CEWs) are used by law enforcement to subdue combative subjects. Occasionally, subjects will die after a CEW has been used on them. It is theorized that CEWs may contribute to these deaths by impairing respiration. To examine the respiratory effects of CEWs. Human volunt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Academic emergency medicine 2007-03, Vol.14 (3), p.197-201
Hauptverfasser: Ho, Jeffrey D, Dawes, Donald M, Bultman, Laura L, Thacker, Jenny L, Skinner, Lisa D, Bahr, Jennifer M, Johnson, Mark A, Miner, James R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Conducted electrical weapons (CEWs) are used by law enforcement to subdue combative subjects. Occasionally, subjects will die after a CEW has been used on them. It is theorized that CEWs may contribute to these deaths by impairing respiration. To examine the respiratory effects of CEWs. Human volunteers received a 15-second application of electrical current from a CEW while wearing a respiratory measurement device. Common respiratory parameters were collected before, during, and after exposure. Health histories and demographic information were also collected. Fifty-two subjects were analyzed. Thirty-four underwent a 15-second continuous exposure, and 18 underwent three 5-second burst exposures. In the continuous application group, the baseline mean tidal volume of 1.1 L increased to 1.8 L during application, the baseline end-tidal CO2 level went from 40.5 mm Hg to 37.3 mm Hg after exposure, the baseline end-tidal oxygen level went from 118.7 mm Hg to 121.3 mm Hg after exposure, and the baseline respiratory rate went from 15.9 breaths/min to 16.4 breaths/min after exposure. In the 5-second burst group, the baseline mean tidal volume increased to 1.85 L during application, the baseline end-tidal CO2 level went from 40.9 mm Hg to 39.1 mm Hg after exposure, the baseline end-tidal oxygen level went from 123.1 mm Hg to 127.0 mm Hg after exposure, and the baseline respiratory rate went from 13.8 breaths/min to 14.6 breaths/min after exposure. Prolonged CEW application did not impair respiratory parameters in this population of volunteers. Further study is recommended to validate these findings in other populations.
ISSN:1069-6563
1553-2712
DOI:10.1111/j.1553-2712.2007.tb01772.x