Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime

A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy Molecular and biomolecular spectroscopy, 2006-01, Vol.63 (1), p.182-188
Hauptverfasser: Ghaedi, Mehrorang, Asadpour, Enayat, Vafaie, Azam
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 188
container_issue 1
container_start_page 182
container_title Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
container_volume 63
creator Ghaedi, Mehrorang
Asadpour, Enayat
Vafaie, Azam
description A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the α-benzoin oxime (α-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using α-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1–13.7μgmL−1 for micellar media. The detection limit is 0.8ngmL−1. The molar absorptivity of complex is 5350Lmol−1cm−1.
doi_str_mv 10.1016/j.saa.2005.04.049
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70199960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1386142505002350</els_id><sourcerecordid>70199960</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-61e0f9534305fc4e2590910ea019edcfcc15aa50f0ab899e7bd3049263c437873</originalsourceid><addsrcrecordid>eNp9kE1OIzEQhb0AEf4OwAZ5hYZFh3K7uxOL1SiCmUhILIC15bjLxFHaDrZ7NGTNhbjInGkcEsEOqaRSVb33pPoIOWMwZMCaq8UwKjUsAeohVLnEHjlkfNwUrCrrATmKcQEAbFzCARmwhld5zQ7J2wO6aJNdY0vjCnUKfjX3yXeYgtW0xYShs04l6x31hk7Cj-l0ekk3o_Hhw2M_r3oefGf77uNsHY19MEon5RLtsLWK9tG6Z_rvvZihW_us8H9thydk36hlxNNdPyZPtzePk9_F3f2v6eTnXaF5zVLRMAQjal5xqI2usKwFCAaogAlstdGa1UrVYEDNxkLgaNbyDKJsuK74aDzix-Rim7sK_qXHmGRno8blUjn0fZSjHCREA1nItkIdfIwBjVwF26nwKhnIDW65kBm33OCWUOUS2XO-C-9n-dkvx451FlxvBZhf_GMxyKgtOp3BhAxett5-E_8fOLOVBg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70199960</pqid></control><display><type>article</type><title>Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Ghaedi, Mehrorang ; Asadpour, Enayat ; Vafaie, Azam</creator><creatorcontrib>Ghaedi, Mehrorang ; Asadpour, Enayat ; Vafaie, Azam</creatorcontrib><description>A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the α-benzoin oxime (α-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using α-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1–13.7μgmL−1 for micellar media. The detection limit is 0.8ngmL−1. The molar absorptivity of complex is 5350Lmol−1cm−1.</description><identifier>ISSN: 1386-1425</identifier><identifier>DOI: 10.1016/j.saa.2005.04.049</identifier><identifier>PMID: 16344251</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Benzoin - analogs &amp; derivatives ; Benzoin - chemistry ; Chromium - analysis ; Cr(III) ion ; Hydrogen-Ion Concentration ; Ions - analysis ; Octoxynol - chemistry ; Oximes - chemistry ; Sensitivity and Specificity ; Spectrophotometric method ; Spectrophotometry, Atomic - methods ; Surface-Active Agents - chemistry ; Surfactant media ; Triton X-100 ; α-Benzoin oxime</subject><ispartof>Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2006-01, Vol.63 (1), p.182-188</ispartof><rights>2005</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-61e0f9534305fc4e2590910ea019edcfcc15aa50f0ab899e7bd3049263c437873</citedby><cites>FETCH-LOGICAL-c351t-61e0f9534305fc4e2590910ea019edcfcc15aa50f0ab899e7bd3049263c437873</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.saa.2005.04.049$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16344251$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ghaedi, Mehrorang</creatorcontrib><creatorcontrib>Asadpour, Enayat</creatorcontrib><creatorcontrib>Vafaie, Azam</creatorcontrib><title>Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime</title><title>Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy</title><addtitle>Spectrochim Acta A Mol Biomol Spectrosc</addtitle><description>A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the α-benzoin oxime (α-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using α-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1–13.7μgmL−1 for micellar media. The detection limit is 0.8ngmL−1. The molar absorptivity of complex is 5350Lmol−1cm−1.</description><subject>Benzoin - analogs &amp; derivatives</subject><subject>Benzoin - chemistry</subject><subject>Chromium - analysis</subject><subject>Cr(III) ion</subject><subject>Hydrogen-Ion Concentration</subject><subject>Ions - analysis</subject><subject>Octoxynol - chemistry</subject><subject>Oximes - chemistry</subject><subject>Sensitivity and Specificity</subject><subject>Spectrophotometric method</subject><subject>Spectrophotometry, Atomic - methods</subject><subject>Surface-Active Agents - chemistry</subject><subject>Surfactant media</subject><subject>Triton X-100</subject><subject>α-Benzoin oxime</subject><issn>1386-1425</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1OIzEQhb0AEf4OwAZ5hYZFh3K7uxOL1SiCmUhILIC15bjLxFHaDrZ7NGTNhbjInGkcEsEOqaRSVb33pPoIOWMwZMCaq8UwKjUsAeohVLnEHjlkfNwUrCrrATmKcQEAbFzCARmwhld5zQ7J2wO6aJNdY0vjCnUKfjX3yXeYgtW0xYShs04l6x31hk7Cj-l0ekk3o_Hhw2M_r3oefGf77uNsHY19MEon5RLtsLWK9tG6Z_rvvZihW_us8H9thydk36hlxNNdPyZPtzePk9_F3f2v6eTnXaF5zVLRMAQjal5xqI2usKwFCAaogAlstdGa1UrVYEDNxkLgaNbyDKJsuK74aDzix-Rim7sK_qXHmGRno8blUjn0fZSjHCREA1nItkIdfIwBjVwF26nwKhnIDW65kBm33OCWUOUS2XO-C-9n-dkvx451FlxvBZhf_GMxyKgtOp3BhAxett5-E_8fOLOVBg</recordid><startdate>200601</startdate><enddate>200601</enddate><creator>Ghaedi, Mehrorang</creator><creator>Asadpour, Enayat</creator><creator>Vafaie, Azam</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200601</creationdate><title>Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime</title><author>Ghaedi, Mehrorang ; Asadpour, Enayat ; Vafaie, Azam</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-61e0f9534305fc4e2590910ea019edcfcc15aa50f0ab899e7bd3049263c437873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Benzoin - analogs &amp; derivatives</topic><topic>Benzoin - chemistry</topic><topic>Chromium - analysis</topic><topic>Cr(III) ion</topic><topic>Hydrogen-Ion Concentration</topic><topic>Ions - analysis</topic><topic>Octoxynol - chemistry</topic><topic>Oximes - chemistry</topic><topic>Sensitivity and Specificity</topic><topic>Spectrophotometric method</topic><topic>Spectrophotometry, Atomic - methods</topic><topic>Surface-Active Agents - chemistry</topic><topic>Surfactant media</topic><topic>Triton X-100</topic><topic>α-Benzoin oxime</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ghaedi, Mehrorang</creatorcontrib><creatorcontrib>Asadpour, Enayat</creatorcontrib><creatorcontrib>Vafaie, Azam</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ghaedi, Mehrorang</au><au>Asadpour, Enayat</au><au>Vafaie, Azam</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime</atitle><jtitle>Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy</jtitle><addtitle>Spectrochim Acta A Mol Biomol Spectrosc</addtitle><date>2006-01</date><risdate>2006</risdate><volume>63</volume><issue>1</issue><spage>182</spage><epage>188</epage><pages>182-188</pages><issn>1386-1425</issn><abstract>A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the α-benzoin oxime (α-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using α-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1–13.7μgmL−1 for micellar media. The detection limit is 0.8ngmL−1. The molar absorptivity of complex is 5350Lmol−1cm−1.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>16344251</pmid><doi>10.1016/j.saa.2005.04.049</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1386-1425
ispartof Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2006-01, Vol.63 (1), p.182-188
issn 1386-1425
language eng
recordid cdi_proquest_miscellaneous_70199960
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Benzoin - analogs & derivatives
Benzoin - chemistry
Chromium - analysis
Cr(III) ion
Hydrogen-Ion Concentration
Ions - analysis
Octoxynol - chemistry
Oximes - chemistry
Sensitivity and Specificity
Spectrophotometric method
Spectrophotometry, Atomic - methods
Surface-Active Agents - chemistry
Surfactant media
Triton X-100
α-Benzoin oxime
title Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T19%3A01%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitized%20spectrophotometric%20determination%20of%20Cr(III)%20ion%20for%20speciation%20of%20chromium%20ion%20in%20surfactant%20media%20using%20%CE%B1-benzoin%20oxime&rft.jtitle=Spectrochimica%20acta.%20Part%20A,%20Molecular%20and%20biomolecular%20spectroscopy&rft.au=Ghaedi,%20Mehrorang&rft.date=2006-01&rft.volume=63&rft.issue=1&rft.spage=182&rft.epage=188&rft.pages=182-188&rft.issn=1386-1425&rft_id=info:doi/10.1016/j.saa.2005.04.049&rft_dat=%3Cproquest_cross%3E70199960%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70199960&rft_id=info:pmid/16344251&rft_els_id=S1386142505002350&rfr_iscdi=true