Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs

The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Dental Materials Journal 2007, Vol.26(5), pp.659-664
Hauptverfasser: KOMINE, Futoshi, IWAI, Takayuki, KOBAYASHI, Kazuhisa, MATSUMURA, Hideo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 664
container_issue 5
container_start_page 659
container_title Dental Materials Journal
container_volume 26
creator KOMINE, Futoshi
IWAI, Takayuki
KOBAYASHI, Kazuhisa
MATSUMURA, Hideo
description The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S), rounded shoulder (RS), and chamfer (C) preparations. Twenty-four standardized ZrO2 ceramic copings were manufactured with a CAD/CAM system (Cercon Smart Ceramics), and the crowns were finalized by veneering with a feldspathic ceramic. Measurements for marginal and internal adaptation were performed at two stages: the copings and the completed crowns. No significant differences were observed between the three groups in terms of marginal discrepancy median value: S, 73/69; RS, 61/60; C, 64/55 (μm). However, significant differences in internal adaptation were widely found among all groups: S, 117/111; RS, 72/75; C, 56/57 (μm). As for intra-group comparisons of marginal and internal adaptation values for all groups, the differences were not significant. It was found that the finish line design seemingly wielded no influence on marginal adaptation of single-tooth ZrO2 ceramic copings and crowns. It was also observed that the marginal and internal adaptation values in the present study were all within the clinically acceptable range.
doi_str_mv 10.4012/dmj.26.659
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70066031</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70066031</sourcerecordid><originalsourceid>FETCH-LOGICAL-c467t-3e9b45f74644f83432e87fbd3a37117840cc65376213ee45bf75a8569bace50c3</originalsourceid><addsrcrecordid>eNpFkE1vEzEQQC1ERdPChR-AfOKAtKm9_swJVVtaKgVxgQsXy-sdJ4527WA7Kv33bEloLx5Z8-YdHkLvKVlyQturYdotW7mUYvUKLajWtKFM0tdoQVqtGi64OkcXpewI4Sup9Rt0TnVLGJdigco3mzch2hHbOOD7WCE_fa4Hu6-2hhRx8vhXyC7FcJjwTUh_wgC4g2yn4HCX9iFuyr_jLqeHWPBDqNuZ8x4yxIpvQwxli9chAr6BEjaxvEVn3o4F3p3mJfp5--VH97VZf7-7767XjeNS1YbBqufCKy4595px1oJWvh-YZYpSpTlxTgqmZEsZABe9V8JqIVe9dSCIY5fo49G7z-n3AUo1UygOxtFGSIdiFCFSEkZn8NMRdDmVksGbfQ6TzY-GEvOU2MyJTSvNnHiGP5ysh36C4QU9NZ2Bz0dgV6rdwDNgcw1uhP8ucXxm5fPGbW02ENlf0D6OYg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>70066031</pqid></control><display><type>article</type><title>Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>KOMINE, Futoshi ; IWAI, Takayuki ; KOBAYASHI, Kazuhisa ; MATSUMURA, Hideo</creator><creatorcontrib>KOMINE, Futoshi ; IWAI, Takayuki ; KOBAYASHI, Kazuhisa ; MATSUMURA, Hideo</creatorcontrib><description>The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S), rounded shoulder (RS), and chamfer (C) preparations. Twenty-four standardized ZrO2 ceramic copings were manufactured with a CAD/CAM system (Cercon Smart Ceramics), and the crowns were finalized by veneering with a feldspathic ceramic. Measurements for marginal and internal adaptation were performed at two stages: the copings and the completed crowns. No significant differences were observed between the three groups in terms of marginal discrepancy median value: S, 73/69; RS, 61/60; C, 64/55 (μm). However, significant differences in internal adaptation were widely found among all groups: S, 117/111; RS, 72/75; C, 56/57 (μm). As for intra-group comparisons of marginal and internal adaptation values for all groups, the differences were not significant. It was found that the finish line design seemingly wielded no influence on marginal adaptation of single-tooth ZrO2 ceramic copings and crowns. It was also observed that the marginal and internal adaptation values in the present study were all within the clinically acceptable range.</description><identifier>ISSN: 0287-4547</identifier><identifier>EISSN: 1881-1361</identifier><identifier>DOI: 10.4012/dmj.26.659</identifier><identifier>PMID: 18203465</identifier><language>eng</language><publisher>Japan: The Japanese Society for Dental Materials and Devices</publisher><subject>Adaptation ; Computer-Aided Design ; Crowns ; Dental Marginal Adaptation ; Dental Porcelain ; Dental Prosthesis Design ; Dentistry ; Finish line ; Incisor ; Statistics, Nonparametric ; Tooth Preparation, Prosthodontic ; Zirconium ; Zirconium dioxide</subject><ispartof>Dental Materials Journal, 2007, Vol.26(5), pp.659-664</ispartof><rights>2007 The Japanese Society for Dental Materials and Devices</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c467t-3e9b45f74644f83432e87fbd3a37117840cc65376213ee45bf75a8569bace50c3</citedby><cites>FETCH-LOGICAL-c467t-3e9b45f74644f83432e87fbd3a37117840cc65376213ee45bf75a8569bace50c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18203465$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KOMINE, Futoshi</creatorcontrib><creatorcontrib>IWAI, Takayuki</creatorcontrib><creatorcontrib>KOBAYASHI, Kazuhisa</creatorcontrib><creatorcontrib>MATSUMURA, Hideo</creatorcontrib><title>Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs</title><title>Dental Materials Journal</title><addtitle>Dent. Mater. J.</addtitle><description>The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S), rounded shoulder (RS), and chamfer (C) preparations. Twenty-four standardized ZrO2 ceramic copings were manufactured with a CAD/CAM system (Cercon Smart Ceramics), and the crowns were finalized by veneering with a feldspathic ceramic. Measurements for marginal and internal adaptation were performed at two stages: the copings and the completed crowns. No significant differences were observed between the three groups in terms of marginal discrepancy median value: S, 73/69; RS, 61/60; C, 64/55 (μm). However, significant differences in internal adaptation were widely found among all groups: S, 117/111; RS, 72/75; C, 56/57 (μm). As for intra-group comparisons of marginal and internal adaptation values for all groups, the differences were not significant. It was found that the finish line design seemingly wielded no influence on marginal adaptation of single-tooth ZrO2 ceramic copings and crowns. It was also observed that the marginal and internal adaptation values in the present study were all within the clinically acceptable range.</description><subject>Adaptation</subject><subject>Computer-Aided Design</subject><subject>Crowns</subject><subject>Dental Marginal Adaptation</subject><subject>Dental Porcelain</subject><subject>Dental Prosthesis Design</subject><subject>Dentistry</subject><subject>Finish line</subject><subject>Incisor</subject><subject>Statistics, Nonparametric</subject><subject>Tooth Preparation, Prosthodontic</subject><subject>Zirconium</subject><subject>Zirconium dioxide</subject><issn>0287-4547</issn><issn>1881-1361</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkE1vEzEQQC1ERdPChR-AfOKAtKm9_swJVVtaKgVxgQsXy-sdJ4527WA7Kv33bEloLx5Z8-YdHkLvKVlyQturYdotW7mUYvUKLajWtKFM0tdoQVqtGi64OkcXpewI4Sup9Rt0TnVLGJdigco3mzch2hHbOOD7WCE_fa4Hu6-2hhRx8vhXyC7FcJjwTUh_wgC4g2yn4HCX9iFuyr_jLqeHWPBDqNuZ8x4yxIpvQwxli9chAr6BEjaxvEVn3o4F3p3mJfp5--VH97VZf7-7767XjeNS1YbBqufCKy4595px1oJWvh-YZYpSpTlxTgqmZEsZABe9V8JqIVe9dSCIY5fo49G7z-n3AUo1UygOxtFGSIdiFCFSEkZn8NMRdDmVksGbfQ6TzY-GEvOU2MyJTSvNnHiGP5ysh36C4QU9NZ2Bz0dgV6rdwDNgcw1uhP8ucXxm5fPGbW02ENlf0D6OYg</recordid><startdate>20070901</startdate><enddate>20070901</enddate><creator>KOMINE, Futoshi</creator><creator>IWAI, Takayuki</creator><creator>KOBAYASHI, Kazuhisa</creator><creator>MATSUMURA, Hideo</creator><general>The Japanese Society for Dental Materials and Devices</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070901</creationdate><title>Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs</title><author>KOMINE, Futoshi ; IWAI, Takayuki ; KOBAYASHI, Kazuhisa ; MATSUMURA, Hideo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c467t-3e9b45f74644f83432e87fbd3a37117840cc65376213ee45bf75a8569bace50c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Adaptation</topic><topic>Computer-Aided Design</topic><topic>Crowns</topic><topic>Dental Marginal Adaptation</topic><topic>Dental Porcelain</topic><topic>Dental Prosthesis Design</topic><topic>Dentistry</topic><topic>Finish line</topic><topic>Incisor</topic><topic>Statistics, Nonparametric</topic><topic>Tooth Preparation, Prosthodontic</topic><topic>Zirconium</topic><topic>Zirconium dioxide</topic><toplevel>online_resources</toplevel><creatorcontrib>KOMINE, Futoshi</creatorcontrib><creatorcontrib>IWAI, Takayuki</creatorcontrib><creatorcontrib>KOBAYASHI, Kazuhisa</creatorcontrib><creatorcontrib>MATSUMURA, Hideo</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Dental Materials Journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KOMINE, Futoshi</au><au>IWAI, Takayuki</au><au>KOBAYASHI, Kazuhisa</au><au>MATSUMURA, Hideo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs</atitle><jtitle>Dental Materials Journal</jtitle><addtitle>Dent. Mater. J.</addtitle><date>2007-09-01</date><risdate>2007</risdate><volume>26</volume><issue>5</issue><spage>659</spage><epage>664</epage><pages>659-664</pages><issn>0287-4547</issn><eissn>1881-1361</eissn><abstract>The present study evaluated the marginal and internal adaptation of single-tooth zirconium dioxide (ZrO2) ceramic copings or crowns with three different finish line designs. Twenty-four steel dies were prepared for maxillary central incisor crowns with the following finish line designs: shoulder (S), rounded shoulder (RS), and chamfer (C) preparations. Twenty-four standardized ZrO2 ceramic copings were manufactured with a CAD/CAM system (Cercon Smart Ceramics), and the crowns were finalized by veneering with a feldspathic ceramic. Measurements for marginal and internal adaptation were performed at two stages: the copings and the completed crowns. No significant differences were observed between the three groups in terms of marginal discrepancy median value: S, 73/69; RS, 61/60; C, 64/55 (μm). However, significant differences in internal adaptation were widely found among all groups: S, 117/111; RS, 72/75; C, 56/57 (μm). As for intra-group comparisons of marginal and internal adaptation values for all groups, the differences were not significant. It was found that the finish line design seemingly wielded no influence on marginal adaptation of single-tooth ZrO2 ceramic copings and crowns. It was also observed that the marginal and internal adaptation values in the present study were all within the clinically acceptable range.</abstract><cop>Japan</cop><pub>The Japanese Society for Dental Materials and Devices</pub><pmid>18203465</pmid><doi>10.4012/dmj.26.659</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0287-4547
ispartof Dental Materials Journal, 2007, Vol.26(5), pp.659-664
issn 0287-4547
1881-1361
language eng
recordid cdi_proquest_miscellaneous_70066031
source J-STAGE Free; MEDLINE; Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals
subjects Adaptation
Computer-Aided Design
Crowns
Dental Marginal Adaptation
Dental Porcelain
Dental Prosthesis Design
Dentistry
Finish line
Incisor
Statistics, Nonparametric
Tooth Preparation, Prosthodontic
Zirconium
Zirconium dioxide
title Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T11%3A01%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Marginal%20and%20Internal%20Adaptation%20of%20Zirconium%20Dioxide%20Ceramic%20Copings%20and%20Crowns%20with%20Different%20Finish%20Line%20Designs&rft.jtitle=Dental%20Materials%20Journal&rft.au=KOMINE,%20Futoshi&rft.date=2007-09-01&rft.volume=26&rft.issue=5&rft.spage=659&rft.epage=664&rft.pages=659-664&rft.issn=0287-4547&rft.eissn=1881-1361&rft_id=info:doi/10.4012/dmj.26.659&rft_dat=%3Cproquest_cross%3E70066031%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=70066031&rft_id=info:pmid/18203465&rfr_iscdi=true