Requirements for clinical use of bioelectrical impedance analysis (BIA)

The bioelectrical impedance analysis (BIA) method is an attractive tool for use in the clinical assessment of human body composition. Factors such as ease of use, relatively low cost, noninvasive nature, high degree of reproducibility, and safety of operation provide an impetus for the general appli...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of the New York Academy of Sciences 1999-04, Vol.873 (1), p.72-76
1. Verfasser: Lukaski, Henry C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 76
container_issue 1
container_start_page 72
container_title Annals of the New York Academy of Sciences
container_volume 873
creator Lukaski, Henry C
description The bioelectrical impedance analysis (BIA) method is an attractive tool for use in the clinical assessment of human body composition. Factors such as ease of use, relatively low cost, noninvasive nature, high degree of reproducibility, and safety of operation provide an impetus for the general application of this method. The preponderance of the published applications of BIA focused on applications in healthy populations and indicated a qualitative validity of the method. More recent applications have augmented the quantitative values of the BIA approach and have reported very good specificity and sensitivity. One potential limitation of the BIA approach is the reliance on regression models, derived in restricted samples of human subjects, which restricts the usefulness of the derived model in other patients who differ from the original sample in which the model was developed. Other investigational approaches that use different physical models (bioelectrical impedance spectroscopy and parallel model) have yielded successful and useful measures of human body composition in clinical studies. If BIA is to gain acceptance in clinical diagnosis and evaluation of therapeutic interventions, further efforts will be needed to ascertain more fully the validity, sensitivity, and specificity of biological parameters estimated with the new BIA approaches, and to establish the prognostic values of the BIA estimates of body composition.
doi_str_mv 10.1111/j.1749-6632.1999.tb09451.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69832426</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69832426</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4982-a8b97c0b73a8fda8f13f122c23e54768738e67291a9ba273cde666013e5e0fb33</originalsourceid><addsrcrecordid>eNqVkE1r3DAQhkVoSbZJ_0Jregjtwa4-vJLVQ2CbZjehSQrZhNLTIGvHRVt_bCSb7v772PUScu2AGNA88w48hHxgNGF9fV4nTKU6llLwhGmtkzanOp2yZHtAJs-jV2RCqVJxprk4Im9CWFPKeJaqQ3LEqFCcTfmELO7wsXMeK6zbEBWNj2zpamdNGXUBo6aIctdgibb1_z5dtcGVqS1GpjblLrgQffx6Nft0Ql4Xpgz4dt-PycP84v78Mr7-sbg6n13HNtUZj02Wa2VproTJilX_mCgY55YLnKZKZkpkKBXXzOjccCXsCqWUlPVjpEUuxDE5HXM3vnnsMLRQuWCxLE2NTRdA6kzwlMse_DKC1jcheCxg411l_A4YhUEjrGFwBYMrGDTCXiNs--V3-ytdXuHqxerorQfORuCvK3H3H9Fw-2u2VENAPAa40OL2OcD4PyCVUFP4ebuAb0v9Xc_VHG56_v3IF6YB89u7AA9L3ouhTFPNuBZPXVWaEg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69832426</pqid></control><display><type>article</type><title>Requirements for clinical use of bioelectrical impedance analysis (BIA)</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Lukaski, Henry C</creator><creatorcontrib>Lukaski, Henry C</creatorcontrib><description>The bioelectrical impedance analysis (BIA) method is an attractive tool for use in the clinical assessment of human body composition. Factors such as ease of use, relatively low cost, noninvasive nature, high degree of reproducibility, and safety of operation provide an impetus for the general application of this method. The preponderance of the published applications of BIA focused on applications in healthy populations and indicated a qualitative validity of the method. More recent applications have augmented the quantitative values of the BIA approach and have reported very good specificity and sensitivity. One potential limitation of the BIA approach is the reliance on regression models, derived in restricted samples of human subjects, which restricts the usefulness of the derived model in other patients who differ from the original sample in which the model was developed. Other investigational approaches that use different physical models (bioelectrical impedance spectroscopy and parallel model) have yielded successful and useful measures of human body composition in clinical studies. If BIA is to gain acceptance in clinical diagnosis and evaluation of therapeutic interventions, further efforts will be needed to ascertain more fully the validity, sensitivity, and specificity of biological parameters estimated with the new BIA approaches, and to establish the prognostic values of the BIA estimates of body composition.</description><identifier>ISSN: 0077-8923</identifier><identifier>EISSN: 1749-6632</identifier><identifier>DOI: 10.1111/j.1749-6632.1999.tb09451.x</identifier><identifier>PMID: 10372152</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>bioelectrical impedance analysis ; Body Composition ; Body Mass Index ; Body Water ; clinical examination ; Electric Impedance ; Electrophysiology ; Guidelines as Topic ; Humans ; impedance ; Sensitivity and Specificity</subject><ispartof>Annals of the New York Academy of Sciences, 1999-04, Vol.873 (1), p.72-76</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4982-a8b97c0b73a8fda8f13f122c23e54768738e67291a9ba273cde666013e5e0fb33</citedby><cites>FETCH-LOGICAL-c4982-a8b97c0b73a8fda8f13f122c23e54768738e67291a9ba273cde666013e5e0fb33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1749-6632.1999.tb09451.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1749-6632.1999.tb09451.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10372152$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lukaski, Henry C</creatorcontrib><title>Requirements for clinical use of bioelectrical impedance analysis (BIA)</title><title>Annals of the New York Academy of Sciences</title><addtitle>Ann N Y Acad Sci</addtitle><description>The bioelectrical impedance analysis (BIA) method is an attractive tool for use in the clinical assessment of human body composition. Factors such as ease of use, relatively low cost, noninvasive nature, high degree of reproducibility, and safety of operation provide an impetus for the general application of this method. The preponderance of the published applications of BIA focused on applications in healthy populations and indicated a qualitative validity of the method. More recent applications have augmented the quantitative values of the BIA approach and have reported very good specificity and sensitivity. One potential limitation of the BIA approach is the reliance on regression models, derived in restricted samples of human subjects, which restricts the usefulness of the derived model in other patients who differ from the original sample in which the model was developed. Other investigational approaches that use different physical models (bioelectrical impedance spectroscopy and parallel model) have yielded successful and useful measures of human body composition in clinical studies. If BIA is to gain acceptance in clinical diagnosis and evaluation of therapeutic interventions, further efforts will be needed to ascertain more fully the validity, sensitivity, and specificity of biological parameters estimated with the new BIA approaches, and to establish the prognostic values of the BIA estimates of body composition.</description><subject>bioelectrical impedance analysis</subject><subject>Body Composition</subject><subject>Body Mass Index</subject><subject>Body Water</subject><subject>clinical examination</subject><subject>Electric Impedance</subject><subject>Electrophysiology</subject><subject>Guidelines as Topic</subject><subject>Humans</subject><subject>impedance</subject><subject>Sensitivity and Specificity</subject><issn>0077-8923</issn><issn>1749-6632</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqVkE1r3DAQhkVoSbZJ_0Jregjtwa4-vJLVQ2CbZjehSQrZhNLTIGvHRVt_bCSb7v772PUScu2AGNA88w48hHxgNGF9fV4nTKU6llLwhGmtkzanOp2yZHtAJs-jV2RCqVJxprk4Im9CWFPKeJaqQ3LEqFCcTfmELO7wsXMeK6zbEBWNj2zpamdNGXUBo6aIctdgibb1_z5dtcGVqS1GpjblLrgQffx6Nft0Ql4Xpgz4dt-PycP84v78Mr7-sbg6n13HNtUZj02Wa2VproTJilX_mCgY55YLnKZKZkpkKBXXzOjccCXsCqWUlPVjpEUuxDE5HXM3vnnsMLRQuWCxLE2NTRdA6kzwlMse_DKC1jcheCxg411l_A4YhUEjrGFwBYMrGDTCXiNs--V3-ytdXuHqxerorQfORuCvK3H3H9Fw-2u2VENAPAa40OL2OcD4PyCVUFP4ebuAb0v9Xc_VHG56_v3IF6YB89u7AA9L3ouhTFPNuBZPXVWaEg</recordid><startdate>199904</startdate><enddate>199904</enddate><creator>Lukaski, Henry C</creator><general>Blackwell Publishing Ltd</general><scope>FBQ</scope><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199904</creationdate><title>Requirements for clinical use of bioelectrical impedance analysis (BIA)</title><author>Lukaski, Henry C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4982-a8b97c0b73a8fda8f13f122c23e54768738e67291a9ba273cde666013e5e0fb33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>bioelectrical impedance analysis</topic><topic>Body Composition</topic><topic>Body Mass Index</topic><topic>Body Water</topic><topic>clinical examination</topic><topic>Electric Impedance</topic><topic>Electrophysiology</topic><topic>Guidelines as Topic</topic><topic>Humans</topic><topic>impedance</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lukaski, Henry C</creatorcontrib><collection>AGRIS</collection><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of the New York Academy of Sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lukaski, Henry C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Requirements for clinical use of bioelectrical impedance analysis (BIA)</atitle><jtitle>Annals of the New York Academy of Sciences</jtitle><addtitle>Ann N Y Acad Sci</addtitle><date>1999-04</date><risdate>1999</risdate><volume>873</volume><issue>1</issue><spage>72</spage><epage>76</epage><pages>72-76</pages><issn>0077-8923</issn><eissn>1749-6632</eissn><abstract>The bioelectrical impedance analysis (BIA) method is an attractive tool for use in the clinical assessment of human body composition. Factors such as ease of use, relatively low cost, noninvasive nature, high degree of reproducibility, and safety of operation provide an impetus for the general application of this method. The preponderance of the published applications of BIA focused on applications in healthy populations and indicated a qualitative validity of the method. More recent applications have augmented the quantitative values of the BIA approach and have reported very good specificity and sensitivity. One potential limitation of the BIA approach is the reliance on regression models, derived in restricted samples of human subjects, which restricts the usefulness of the derived model in other patients who differ from the original sample in which the model was developed. Other investigational approaches that use different physical models (bioelectrical impedance spectroscopy and parallel model) have yielded successful and useful measures of human body composition in clinical studies. If BIA is to gain acceptance in clinical diagnosis and evaluation of therapeutic interventions, further efforts will be needed to ascertain more fully the validity, sensitivity, and specificity of biological parameters estimated with the new BIA approaches, and to establish the prognostic values of the BIA estimates of body composition.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>10372152</pmid><doi>10.1111/j.1749-6632.1999.tb09451.x</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0077-8923
ispartof Annals of the New York Academy of Sciences, 1999-04, Vol.873 (1), p.72-76
issn 0077-8923
1749-6632
language eng
recordid cdi_proquest_miscellaneous_69832426
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects bioelectrical impedance analysis
Body Composition
Body Mass Index
Body Water
clinical examination
Electric Impedance
Electrophysiology
Guidelines as Topic
Humans
impedance
Sensitivity and Specificity
title Requirements for clinical use of bioelectrical impedance analysis (BIA)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T19%3A22%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Requirements%20for%20clinical%20use%20of%20bioelectrical%20impedance%20analysis%20(BIA)&rft.jtitle=Annals%20of%20the%20New%20York%20Academy%20of%20Sciences&rft.au=Lukaski,%20Henry%20C&rft.date=1999-04&rft.volume=873&rft.issue=1&rft.spage=72&rft.epage=76&rft.pages=72-76&rft.issn=0077-8923&rft.eissn=1749-6632&rft_id=info:doi/10.1111/j.1749-6632.1999.tb09451.x&rft_dat=%3Cproquest_cross%3E69832426%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69832426&rft_id=info:pmid/10372152&rfr_iscdi=true