Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments

The aim of this study was to analyse the vertical forces and torque developed in the root canal system of extracted teeth during mechanical preparation using ProFile NiTi instruments. Instrument wear and fracture is in great part due to the repeated application of forces and torque during the course...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International endodontic journal 1999-01, Vol.32 (1), p.24-31
Hauptverfasser: Blum, J Y, Cohen, A, Machtou, P, Micallef, J P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 31
container_issue 1
container_start_page 24
container_title International endodontic journal
container_volume 32
creator Blum, J Y
Cohen, A
Machtou, P
Micallef, J P
description The aim of this study was to analyse the vertical forces and torque developed in the root canal system of extracted teeth during mechanical preparation using ProFile NiTi instruments. Instrument wear and fracture is in great part due to the repeated application of forces and torque during the course of root-canal preparation but research into the direct relationship has been hampered by the lack of adequate measuring devices. Measurements of these forces and torque were made with a new force analyser device, the Endographe, that was equipped with a holder to record and generate graphs of the vertical forces and torque exerted during the preparations. These preparations was performed by endodontists or students either with a series of instruments of increasing size or with the crown-down pressureless technique. The mean values for the endodontists of the generated vertical forces and torque varied, respectively, from 4 to 6N and from 7.105 to 12.105 Nm for the step-back technique and from 2.9 to 4.2 N and from 18.105 to 20.105 Nm for the crown-down technique. This suggested that the crown-down technique generated lower stresses (lower torque and lower vertical forces), although these findings also depend on the shape of individual canals. The students initially showed wide variations in generated forces, with significantly lower vertical force the torque values. By the end of the experimental sessions their values were similar to those of the endodontists, which indicated improvement in the efficiency of manipulation. Further work is needed to investigate the relationship between the force and the torque data from this study and the incidence of instrument fracture with the two techniques, as the clinical implications are considerable. It must be noted, however, that the Endographe is unable to take into account the cutting efficiency of the instruments. The use of graphs provides a new approach to the analysis of mechanical preparation.
doi_str_mv 10.1046/j.1365-2591.1999.00181.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69797301</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69797301</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-bb049172131b5d8f9c97b2e8b10006e9f1a353c8658bcbfaef3a400e39790fd73</originalsourceid><addsrcrecordid>eNpNkMlOwzAQhi0EomV5BeQTtwRPnc1HhNgkBBzK2XKcMXWVxMF2UHl7EooQpznM98_yEUKBpcCy4mqbAi_yZJULSEEIkTIGFaS7A7L8axySJYOMJ6uqyhfkJIQtYyxnHI7JAhjPi6woliRc96r9CjZQZ6hxXmOgDX5i6wZsaDN627_TDvVG9Varlg4eB-VVtK6fE7iLXuk4oRExbugYZv7VO2NbpM92bal3UfkvavsQ_dhhH8MZOTKqDXj-W0_J293t-uYheXq5f7y5fko0B4hJXbNMQLkCDnXeVEZoUdYrrGqYHilQGFA857oq8qrWtVFouMoYQy5KwUxT8lNyuZ87ePcxYoiys0Fj26oe3RhkMYElZzCB1R7U3oXg0cjB2266WgKTs3C5lbNXOXuVs3D5I1zupujF746x7rD5F9wb5t8j3X9x</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69797301</pqid></control><display><type>article</type><title>Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Blum, J Y ; Cohen, A ; Machtou, P ; Micallef, J P</creator><creatorcontrib>Blum, J Y ; Cohen, A ; Machtou, P ; Micallef, J P</creatorcontrib><description>The aim of this study was to analyse the vertical forces and torque developed in the root canal system of extracted teeth during mechanical preparation using ProFile NiTi instruments. Instrument wear and fracture is in great part due to the repeated application of forces and torque during the course of root-canal preparation but research into the direct relationship has been hampered by the lack of adequate measuring devices. Measurements of these forces and torque were made with a new force analyser device, the Endographe, that was equipped with a holder to record and generate graphs of the vertical forces and torque exerted during the preparations. These preparations was performed by endodontists or students either with a series of instruments of increasing size or with the crown-down pressureless technique. The mean values for the endodontists of the generated vertical forces and torque varied, respectively, from 4 to 6N and from 7.105 to 12.105 Nm for the step-back technique and from 2.9 to 4.2 N and from 18.105 to 20.105 Nm for the crown-down technique. This suggested that the crown-down technique generated lower stresses (lower torque and lower vertical forces), although these findings also depend on the shape of individual canals. The students initially showed wide variations in generated forces, with significantly lower vertical force the torque values. By the end of the experimental sessions their values were similar to those of the endodontists, which indicated improvement in the efficiency of manipulation. Further work is needed to investigate the relationship between the force and the torque data from this study and the incidence of instrument fracture with the two techniques, as the clinical implications are considerable. It must be noted, however, that the Endographe is unable to take into account the cutting efficiency of the instruments. The use of graphs provides a new approach to the analysis of mechanical preparation.</description><identifier>ISSN: 0143-2885</identifier><identifier>EISSN: 1365-2591</identifier><identifier>DOI: 10.1046/j.1365-2591.1999.00181.x</identifier><identifier>PMID: 10356466</identifier><language>eng</language><publisher>England</publisher><subject>Analysis of Variance ; Dental Instruments ; Dental Stress Analysis ; Dentistry ; Humans ; Nickel ; Root Canal Preparation - instrumentation ; Titanium ; Torque</subject><ispartof>International endodontic journal, 1999-01, Vol.32 (1), p.24-31</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-bb049172131b5d8f9c97b2e8b10006e9f1a353c8658bcbfaef3a400e39790fd73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10356466$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Blum, J Y</creatorcontrib><creatorcontrib>Cohen, A</creatorcontrib><creatorcontrib>Machtou, P</creatorcontrib><creatorcontrib>Micallef, J P</creatorcontrib><title>Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments</title><title>International endodontic journal</title><addtitle>Int Endod J</addtitle><description>The aim of this study was to analyse the vertical forces and torque developed in the root canal system of extracted teeth during mechanical preparation using ProFile NiTi instruments. Instrument wear and fracture is in great part due to the repeated application of forces and torque during the course of root-canal preparation but research into the direct relationship has been hampered by the lack of adequate measuring devices. Measurements of these forces and torque were made with a new force analyser device, the Endographe, that was equipped with a holder to record and generate graphs of the vertical forces and torque exerted during the preparations. These preparations was performed by endodontists or students either with a series of instruments of increasing size or with the crown-down pressureless technique. The mean values for the endodontists of the generated vertical forces and torque varied, respectively, from 4 to 6N and from 7.105 to 12.105 Nm for the step-back technique and from 2.9 to 4.2 N and from 18.105 to 20.105 Nm for the crown-down technique. This suggested that the crown-down technique generated lower stresses (lower torque and lower vertical forces), although these findings also depend on the shape of individual canals. The students initially showed wide variations in generated forces, with significantly lower vertical force the torque values. By the end of the experimental sessions their values were similar to those of the endodontists, which indicated improvement in the efficiency of manipulation. Further work is needed to investigate the relationship between the force and the torque data from this study and the incidence of instrument fracture with the two techniques, as the clinical implications are considerable. It must be noted, however, that the Endographe is unable to take into account the cutting efficiency of the instruments. The use of graphs provides a new approach to the analysis of mechanical preparation.</description><subject>Analysis of Variance</subject><subject>Dental Instruments</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Nickel</subject><subject>Root Canal Preparation - instrumentation</subject><subject>Titanium</subject><subject>Torque</subject><issn>0143-2885</issn><issn>1365-2591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkMlOwzAQhi0EomV5BeQTtwRPnc1HhNgkBBzK2XKcMXWVxMF2UHl7EooQpznM98_yEUKBpcCy4mqbAi_yZJULSEEIkTIGFaS7A7L8axySJYOMJ6uqyhfkJIQtYyxnHI7JAhjPi6woliRc96r9CjZQZ6hxXmOgDX5i6wZsaDN627_TDvVG9Varlg4eB-VVtK6fE7iLXuk4oRExbugYZv7VO2NbpM92bal3UfkvavsQ_dhhH8MZOTKqDXj-W0_J293t-uYheXq5f7y5fko0B4hJXbNMQLkCDnXeVEZoUdYrrGqYHilQGFA857oq8qrWtVFouMoYQy5KwUxT8lNyuZ87ePcxYoiys0Fj26oe3RhkMYElZzCB1R7U3oXg0cjB2266WgKTs3C5lbNXOXuVs3D5I1zupujF746x7rD5F9wb5t8j3X9x</recordid><startdate>199901</startdate><enddate>199901</enddate><creator>Blum, J Y</creator><creator>Cohen, A</creator><creator>Machtou, P</creator><creator>Micallef, J P</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199901</creationdate><title>Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments</title><author>Blum, J Y ; Cohen, A ; Machtou, P ; Micallef, J P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-bb049172131b5d8f9c97b2e8b10006e9f1a353c8658bcbfaef3a400e39790fd73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Analysis of Variance</topic><topic>Dental Instruments</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Nickel</topic><topic>Root Canal Preparation - instrumentation</topic><topic>Titanium</topic><topic>Torque</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Blum, J Y</creatorcontrib><creatorcontrib>Cohen, A</creatorcontrib><creatorcontrib>Machtou, P</creatorcontrib><creatorcontrib>Micallef, J P</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International endodontic journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Blum, J Y</au><au>Cohen, A</au><au>Machtou, P</au><au>Micallef, J P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments</atitle><jtitle>International endodontic journal</jtitle><addtitle>Int Endod J</addtitle><date>1999-01</date><risdate>1999</risdate><volume>32</volume><issue>1</issue><spage>24</spage><epage>31</epage><pages>24-31</pages><issn>0143-2885</issn><eissn>1365-2591</eissn><abstract>The aim of this study was to analyse the vertical forces and torque developed in the root canal system of extracted teeth during mechanical preparation using ProFile NiTi instruments. Instrument wear and fracture is in great part due to the repeated application of forces and torque during the course of root-canal preparation but research into the direct relationship has been hampered by the lack of adequate measuring devices. Measurements of these forces and torque were made with a new force analyser device, the Endographe, that was equipped with a holder to record and generate graphs of the vertical forces and torque exerted during the preparations. These preparations was performed by endodontists or students either with a series of instruments of increasing size or with the crown-down pressureless technique. The mean values for the endodontists of the generated vertical forces and torque varied, respectively, from 4 to 6N and from 7.105 to 12.105 Nm for the step-back technique and from 2.9 to 4.2 N and from 18.105 to 20.105 Nm for the crown-down technique. This suggested that the crown-down technique generated lower stresses (lower torque and lower vertical forces), although these findings also depend on the shape of individual canals. The students initially showed wide variations in generated forces, with significantly lower vertical force the torque values. By the end of the experimental sessions their values were similar to those of the endodontists, which indicated improvement in the efficiency of manipulation. Further work is needed to investigate the relationship between the force and the torque data from this study and the incidence of instrument fracture with the two techniques, as the clinical implications are considerable. It must be noted, however, that the Endographe is unable to take into account the cutting efficiency of the instruments. The use of graphs provides a new approach to the analysis of mechanical preparation.</abstract><cop>England</cop><pmid>10356466</pmid><doi>10.1046/j.1365-2591.1999.00181.x</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0143-2885
ispartof International endodontic journal, 1999-01, Vol.32 (1), p.24-31
issn 0143-2885
1365-2591
language eng
recordid cdi_proquest_miscellaneous_69797301
source MEDLINE; Wiley Online Library All Journals
subjects Analysis of Variance
Dental Instruments
Dental Stress Analysis
Dentistry
Humans
Nickel
Root Canal Preparation - instrumentation
Titanium
Torque
title Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T20%3A12%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20forces%20developed%20during%20mechanical%20preparation%20of%20extracted%20teeth%20using%20Profile%20NiTi%20rotary%20instruments&rft.jtitle=International%20endodontic%20journal&rft.au=Blum,%20J%20Y&rft.date=1999-01&rft.volume=32&rft.issue=1&rft.spage=24&rft.epage=31&rft.pages=24-31&rft.issn=0143-2885&rft.eissn=1365-2591&rft_id=info:doi/10.1046/j.1365-2591.1999.00181.x&rft_dat=%3Cproquest_cross%3E69797301%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69797301&rft_id=info:pmid/10356466&rfr_iscdi=true