Fritless capillary electrochromatography

The preparation of packed capillaries with stable frits of good quality can be a hurdle to obtain efficient separations in capillary electrochromatography (CEC). Especially with particles smaller than 3 μm, frit preparation is cumbersome. Highly efficient separations using packed capillaries without...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrophoresis 1999-01, Vol.20 (1), p.43-49
Hauptverfasser: Mayer, Michael, Rapp, Erdmann, Marck, Caroline, Bruin, Gerard J. M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 49
container_issue 1
container_start_page 43
container_title Electrophoresis
container_volume 20
creator Mayer, Michael
Rapp, Erdmann
Marck, Caroline
Bruin, Gerard J. M.
description The preparation of packed capillaries with stable frits of good quality can be a hurdle to obtain efficient separations in capillary electrochromatography (CEC). Especially with particles smaller than 3 μm, frit preparation is cumbersome. Highly efficient separations using packed capillaries without frits are presented. Under appropriate CEC conditions the particles were retained by electrophoretic attraction towards the anode by a tapered capillary inlet, without the need of a frit at the outlet end. Such fritless capillaries, packed with 1.5 μm nonporous reversed‐phase particles, allowed separations with efficiencies of more than 500 000 plates/m. Once the capillaries were conditioned properly, more than 100 separations could be performed with good repeatability. With respect to separation efficiency, fritless capillaries packed with 3 μm particles were comparable with standard CEC capillaries with frits. Examples of separations of steroids, a pesticide and its by‐products, and cardiac glycosides under various CEC conditions are shown.
doi_str_mv 10.1002/(SICI)1522-2683(19990101)20:1<43::AID-ELPS43>3.0.CO;2-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69602709</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69602709</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3223-23efc105a9bf8b43a6e7dc1ce0a126651462845da0cec5fe46b31b0103a6787e3</originalsourceid><addsrcrecordid>eNqFkFFv0zAUhS0EYmXwF9CeUPeQcu1rO0lBQyNbR6VqRSqo8HTluA7LSJdip4L--7lKmZBA4smS9fmc44-xdxxGHEC8Hi6mxfSUKyESoTMc8jzPgQM_FTDmbyWOx-fTi-Ry9nEh8QxHMCrmb0SSPWKDhzeP2QB4iglkqI7YsxBuAUDmUj5lR7FDq1ylAzac-LprXAgn1mzqpjF-d-IaZzvf2hvfrk3XfvNmc7N7zp5UpgnuxeE8Zp8nl5-KD8lsfjUtzmeJRSEwEegqy0GZvKyyUqLRLl1Zbh0YLrRWXGqRSbUyYJ1VlZO6RF7Gr0UyzVKHx-xVn7vx7Y-tCx2t62BdXHbn2m0gnWsQKeQRXPag9W0I3lW08fU67icOtJdItJdIeyG0F0K_JZKIAEkkihKpl0hIQMWcBGUx-eVhwrZcu9Ufub21CHztgZ9143Z_9f6v9p-th5uYnfTZdejcr4ds47-TTjFVtLy-oi9LzK4n_D0t8B5415ve</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69602709</pqid></control><display><type>article</type><title>Fritless capillary electrochromatography</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Mayer, Michael ; Rapp, Erdmann ; Marck, Caroline ; Bruin, Gerard J. M.</creator><creatorcontrib>Mayer, Michael ; Rapp, Erdmann ; Marck, Caroline ; Bruin, Gerard J. M.</creatorcontrib><description>The preparation of packed capillaries with stable frits of good quality can be a hurdle to obtain efficient separations in capillary electrochromatography (CEC). Especially with particles smaller than 3 μm, frit preparation is cumbersome. Highly efficient separations using packed capillaries without frits are presented. Under appropriate CEC conditions the particles were retained by electrophoretic attraction towards the anode by a tapered capillary inlet, without the need of a frit at the outlet end. Such fritless capillaries, packed with 1.5 μm nonporous reversed‐phase particles, allowed separations with efficiencies of more than 500 000 plates/m. Once the capillaries were conditioned properly, more than 100 separations could be performed with good repeatability. With respect to separation efficiency, fritless capillaries packed with 3 μm particles were comparable with standard CEC capillaries with frits. Examples of separations of steroids, a pesticide and its by‐products, and cardiac glycosides under various CEC conditions are shown.</description><identifier>ISSN: 0173-0835</identifier><identifier>EISSN: 1522-2683</identifier><identifier>DOI: 10.1002/(SICI)1522-2683(19990101)20:1&lt;43::AID-ELPS43&gt;3.0.CO;2-8</identifier><identifier>PMID: 10065957</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Capillary electrochromatography ; Chromatography, Liquid - methods ; Frit manufacturing ; Stereoids ; Tapered capillaries</subject><ispartof>Electrophoresis, 1999-01, Vol.20 (1), p.43-49</ispartof><rights>Copyright © 1999 WILEY‐VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3223-23efc105a9bf8b43a6e7dc1ce0a126651462845da0cec5fe46b31b0103a6787e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2F%28SICI%291522-2683%2819990101%2920%3A1%3C43%3A%3AAID-ELPS43%3E3.0.CO%3B2-8$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2F%28SICI%291522-2683%2819990101%2920%3A1%3C43%3A%3AAID-ELPS43%3E3.0.CO%3B2-8$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10065957$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mayer, Michael</creatorcontrib><creatorcontrib>Rapp, Erdmann</creatorcontrib><creatorcontrib>Marck, Caroline</creatorcontrib><creatorcontrib>Bruin, Gerard J. M.</creatorcontrib><title>Fritless capillary electrochromatography</title><title>Electrophoresis</title><addtitle>ELECTROPHORESIS</addtitle><description>The preparation of packed capillaries with stable frits of good quality can be a hurdle to obtain efficient separations in capillary electrochromatography (CEC). Especially with particles smaller than 3 μm, frit preparation is cumbersome. Highly efficient separations using packed capillaries without frits are presented. Under appropriate CEC conditions the particles were retained by electrophoretic attraction towards the anode by a tapered capillary inlet, without the need of a frit at the outlet end. Such fritless capillaries, packed with 1.5 μm nonporous reversed‐phase particles, allowed separations with efficiencies of more than 500 000 plates/m. Once the capillaries were conditioned properly, more than 100 separations could be performed with good repeatability. With respect to separation efficiency, fritless capillaries packed with 3 μm particles were comparable with standard CEC capillaries with frits. Examples of separations of steroids, a pesticide and its by‐products, and cardiac glycosides under various CEC conditions are shown.</description><subject>Capillary electrochromatography</subject><subject>Chromatography, Liquid - methods</subject><subject>Frit manufacturing</subject><subject>Stereoids</subject><subject>Tapered capillaries</subject><issn>0173-0835</issn><issn>1522-2683</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkFFv0zAUhS0EYmXwF9CeUPeQcu1rO0lBQyNbR6VqRSqo8HTluA7LSJdip4L--7lKmZBA4smS9fmc44-xdxxGHEC8Hi6mxfSUKyESoTMc8jzPgQM_FTDmbyWOx-fTi-Ry9nEh8QxHMCrmb0SSPWKDhzeP2QB4iglkqI7YsxBuAUDmUj5lR7FDq1ylAzac-LprXAgn1mzqpjF-d-IaZzvf2hvfrk3XfvNmc7N7zp5UpgnuxeE8Zp8nl5-KD8lsfjUtzmeJRSEwEegqy0GZvKyyUqLRLl1Zbh0YLrRWXGqRSbUyYJ1VlZO6RF7Gr0UyzVKHx-xVn7vx7Y-tCx2t62BdXHbn2m0gnWsQKeQRXPag9W0I3lW08fU67icOtJdItJdIeyG0F0K_JZKIAEkkihKpl0hIQMWcBGUx-eVhwrZcu9Ufub21CHztgZ9143Z_9f6v9p-th5uYnfTZdejcr4ds47-TTjFVtLy-oi9LzK4n_D0t8B5415ve</recordid><startdate>19990101</startdate><enddate>19990101</enddate><creator>Mayer, Michael</creator><creator>Rapp, Erdmann</creator><creator>Marck, Caroline</creator><creator>Bruin, Gerard J. M.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19990101</creationdate><title>Fritless capillary electrochromatography</title><author>Mayer, Michael ; Rapp, Erdmann ; Marck, Caroline ; Bruin, Gerard J. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3223-23efc105a9bf8b43a6e7dc1ce0a126651462845da0cec5fe46b31b0103a6787e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Capillary electrochromatography</topic><topic>Chromatography, Liquid - methods</topic><topic>Frit manufacturing</topic><topic>Stereoids</topic><topic>Tapered capillaries</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mayer, Michael</creatorcontrib><creatorcontrib>Rapp, Erdmann</creatorcontrib><creatorcontrib>Marck, Caroline</creatorcontrib><creatorcontrib>Bruin, Gerard J. M.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Electrophoresis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mayer, Michael</au><au>Rapp, Erdmann</au><au>Marck, Caroline</au><au>Bruin, Gerard J. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fritless capillary electrochromatography</atitle><jtitle>Electrophoresis</jtitle><addtitle>ELECTROPHORESIS</addtitle><date>1999-01-01</date><risdate>1999</risdate><volume>20</volume><issue>1</issue><spage>43</spage><epage>49</epage><pages>43-49</pages><issn>0173-0835</issn><eissn>1522-2683</eissn><abstract>The preparation of packed capillaries with stable frits of good quality can be a hurdle to obtain efficient separations in capillary electrochromatography (CEC). Especially with particles smaller than 3 μm, frit preparation is cumbersome. Highly efficient separations using packed capillaries without frits are presented. Under appropriate CEC conditions the particles were retained by electrophoretic attraction towards the anode by a tapered capillary inlet, without the need of a frit at the outlet end. Such fritless capillaries, packed with 1.5 μm nonporous reversed‐phase particles, allowed separations with efficiencies of more than 500 000 plates/m. Once the capillaries were conditioned properly, more than 100 separations could be performed with good repeatability. With respect to separation efficiency, fritless capillaries packed with 3 μm particles were comparable with standard CEC capillaries with frits. Examples of separations of steroids, a pesticide and its by‐products, and cardiac glycosides under various CEC conditions are shown.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>10065957</pmid><doi>10.1002/(SICI)1522-2683(19990101)20:1&lt;43::AID-ELPS43&gt;3.0.CO;2-8</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0173-0835
ispartof Electrophoresis, 1999-01, Vol.20 (1), p.43-49
issn 0173-0835
1522-2683
language eng
recordid cdi_proquest_miscellaneous_69602709
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Capillary electrochromatography
Chromatography, Liquid - methods
Frit manufacturing
Stereoids
Tapered capillaries
title Fritless capillary electrochromatography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T03%3A06%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fritless%20capillary%20electrochromatography&rft.jtitle=Electrophoresis&rft.au=Mayer,%20Michael&rft.date=1999-01-01&rft.volume=20&rft.issue=1&rft.spage=43&rft.epage=49&rft.pages=43-49&rft.issn=0173-0835&rft.eissn=1522-2683&rft_id=info:doi/10.1002/(SICI)1522-2683(19990101)20:1%3C43::AID-ELPS43%3E3.0.CO;2-8&rft_dat=%3Cproquest_cross%3E69602709%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69602709&rft_id=info:pmid/10065957&rfr_iscdi=true