Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects

With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med‐El Combi 40/40+ cochlear implant, within a wide range of clinical MRI a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 1999-01, Vol.9 (1), p.26-38
Hauptverfasser: Teissl, Christian, Kremser, Christian, Hochmair, Erwin S., Hochmair-Desoyer, Ingeborg J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 38
container_issue 1
container_start_page 26
container_title Journal of magnetic resonance imaging
container_volume 9
creator Teissl, Christian
Kremser, Christian
Hochmair, Erwin S.
Hochmair-Desoyer, Ingeborg J.
description With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med‐El Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken. J. Magn. Reson. Imaging 1999;9:26–38 © 1999 Wiley‐Liss, Inc.
doi_str_mv 10.1002/(SICI)1522-2586(199901)9:1<26::AID-JMRI4>3.0.CO;2-H
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69590761</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69590761</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4734-95e3373c8d978dfa914dd92767ca01130860c4776233828a3ee9fa88787c47143</originalsourceid><addsrcrecordid>eNp9kF1L3EAUhofSUq32L5RciV5kOx_JfKwiSNq6KboLq2LvDuNksk7NJmkmS7v_vhMjIlR6NYfDw_vOeRA6JnhCMKafD6_yLD8iKaUxTSU_JEopTI7UlJxQPp2e5V_i75fLPDllEzzJFsc0nr1Bu8_82zDjlMVEYrGDPnj_E2OsVJK-Rzshn2GeiF20vNSr2vbORJ31Ta1rYyO31itXryJdF5FpzH1ldReWbaXr3k-jrFm3und3rnL99hHyurTD6Ftrer-P3pW68vbj07uHbr59vc5m8cXiPM_OLmKTCJbEKrWMCWZkoYQsSq1IUhSKCi6MxoQwLDkOpOCUMUmlZtaqUksppAhrkrA9dDDmtl3za2N9D2vnja3CN22z8cBVqrDgJIBXI2i6xvvOltB24cZuCwTDoBpgUA2DOhjUwagaFBCgHCCohkfVwABDtgAKs5D66al-c7e2xYvM0W0Arkfgt6vs9p_O_1a-1jguQmw8xjrf2z_Psbp7AC6YSOF2fg5Lmt3-mM_nQNlfMPqnfg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69590761</pqid></control><display><type>article</type><title>Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Wiley Free Content</source><creator>Teissl, Christian ; Kremser, Christian ; Hochmair, Erwin S. ; Hochmair-Desoyer, Ingeborg J.</creator><creatorcontrib>Teissl, Christian ; Kremser, Christian ; Hochmair, Erwin S. ; Hochmair-Desoyer, Ingeborg J.</creatorcontrib><description>With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med‐El Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken. J. Magn. Reson. Imaging 1999;9:26–38 © 1999 Wiley‐Liss, Inc.</description><identifier>ISSN: 1053-1807</identifier><identifier>EISSN: 1522-2586</identifier><identifier>DOI: 10.1002/(SICI)1522-2586(199901)9:1&lt;26::AID-JMRI4&gt;3.0.CO;2-H</identifier><identifier>PMID: 10030647</identifier><language>eng</language><publisher>New York: John Wiley &amp; Sons, Inc</publisher><subject>cochlear implant ; Cochlear Implants ; compatibility ; Contraindications ; Electricity ; Electromagnetic Fields ; electromagnetic interference ; Humans ; Magnetic Resonance Imaging ; Phantoms, Imaging ; Safety</subject><ispartof>Journal of magnetic resonance imaging, 1999-01, Vol.9 (1), p.26-38</ispartof><rights>Copyright © 1999 Wiley‐Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c4734-95e3373c8d978dfa914dd92767ca01130860c4776233828a3ee9fa88787c47143</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2F%28SICI%291522-2586%28199901%299%3A1%3C26%3A%3AAID-JMRI4%3E3.0.CO%3B2-H$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2F%28SICI%291522-2586%28199901%299%3A1%3C26%3A%3AAID-JMRI4%3E3.0.CO%3B2-H$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,1428,27905,27906,45555,45556,46390,46814</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10030647$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Teissl, Christian</creatorcontrib><creatorcontrib>Kremser, Christian</creatorcontrib><creatorcontrib>Hochmair, Erwin S.</creatorcontrib><creatorcontrib>Hochmair-Desoyer, Ingeborg J.</creatorcontrib><title>Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects</title><title>Journal of magnetic resonance imaging</title><addtitle>J. Magn. Reson. Imaging</addtitle><description>With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med‐El Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken. J. Magn. Reson. Imaging 1999;9:26–38 © 1999 Wiley‐Liss, Inc.</description><subject>cochlear implant</subject><subject>Cochlear Implants</subject><subject>compatibility</subject><subject>Contraindications</subject><subject>Electricity</subject><subject>Electromagnetic Fields</subject><subject>electromagnetic interference</subject><subject>Humans</subject><subject>Magnetic Resonance Imaging</subject><subject>Phantoms, Imaging</subject><subject>Safety</subject><issn>1053-1807</issn><issn>1522-2586</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kF1L3EAUhofSUq32L5RciV5kOx_JfKwiSNq6KboLq2LvDuNksk7NJmkmS7v_vhMjIlR6NYfDw_vOeRA6JnhCMKafD6_yLD8iKaUxTSU_JEopTI7UlJxQPp2e5V_i75fLPDllEzzJFsc0nr1Bu8_82zDjlMVEYrGDPnj_E2OsVJK-Rzshn2GeiF20vNSr2vbORJ31Ta1rYyO31itXryJdF5FpzH1ldReWbaXr3k-jrFm3und3rnL99hHyurTD6Ftrer-P3pW68vbj07uHbr59vc5m8cXiPM_OLmKTCJbEKrWMCWZkoYQsSq1IUhSKCi6MxoQwLDkOpOCUMUmlZtaqUksppAhrkrA9dDDmtl3za2N9D2vnja3CN22z8cBVqrDgJIBXI2i6xvvOltB24cZuCwTDoBpgUA2DOhjUwagaFBCgHCCohkfVwABDtgAKs5D66al-c7e2xYvM0W0Arkfgt6vs9p_O_1a-1jguQmw8xjrf2z_Psbp7AC6YSOF2fg5Lmt3-mM_nQNlfMPqnfg</recordid><startdate>199901</startdate><enddate>199901</enddate><creator>Teissl, Christian</creator><creator>Kremser, Christian</creator><creator>Hochmair, Erwin S.</creator><creator>Hochmair-Desoyer, Ingeborg J.</creator><general>John Wiley &amp; Sons, Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199901</creationdate><title>Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects</title><author>Teissl, Christian ; Kremser, Christian ; Hochmair, Erwin S. ; Hochmair-Desoyer, Ingeborg J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4734-95e3373c8d978dfa914dd92767ca01130860c4776233828a3ee9fa88787c47143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>cochlear implant</topic><topic>Cochlear Implants</topic><topic>compatibility</topic><topic>Contraindications</topic><topic>Electricity</topic><topic>Electromagnetic Fields</topic><topic>electromagnetic interference</topic><topic>Humans</topic><topic>Magnetic Resonance Imaging</topic><topic>Phantoms, Imaging</topic><topic>Safety</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Teissl, Christian</creatorcontrib><creatorcontrib>Kremser, Christian</creatorcontrib><creatorcontrib>Hochmair, Erwin S.</creatorcontrib><creatorcontrib>Hochmair-Desoyer, Ingeborg J.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Teissl, Christian</au><au>Kremser, Christian</au><au>Hochmair, Erwin S.</au><au>Hochmair-Desoyer, Ingeborg J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects</atitle><jtitle>Journal of magnetic resonance imaging</jtitle><addtitle>J. Magn. Reson. Imaging</addtitle><date>1999-01</date><risdate>1999</risdate><volume>9</volume><issue>1</issue><spage>26</spage><epage>38</epage><pages>26-38</pages><issn>1053-1807</issn><eissn>1522-2586</eissn><abstract>With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med‐El Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken. J. Magn. Reson. Imaging 1999;9:26–38 © 1999 Wiley‐Liss, Inc.</abstract><cop>New York</cop><pub>John Wiley &amp; Sons, Inc</pub><pmid>10030647</pmid><doi>10.1002/(SICI)1522-2586(199901)9:1&lt;26::AID-JMRI4&gt;3.0.CO;2-H</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1053-1807
ispartof Journal of magnetic resonance imaging, 1999-01, Vol.9 (1), p.26-38
issn 1053-1807
1522-2586
language eng
recordid cdi_proquest_miscellaneous_69590761
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Wiley Free Content
subjects cochlear implant
Cochlear Implants
compatibility
Contraindications
Electricity
Electromagnetic Fields
electromagnetic interference
Humans
Magnetic Resonance Imaging
Phantoms, Imaging
Safety
title Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T23%3A58%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Magnetic%20resonance%20imaging%20and%20cochlear%20implants:%20Compatibility%20and%20safety%20aspects&rft.jtitle=Journal%20of%20magnetic%20resonance%20imaging&rft.au=Teissl,%20Christian&rft.date=1999-01&rft.volume=9&rft.issue=1&rft.spage=26&rft.epage=38&rft.pages=26-38&rft.issn=1053-1807&rft.eissn=1522-2586&rft_id=info:doi/10.1002/(SICI)1522-2586(199901)9:1%3C26::AID-JMRI4%3E3.0.CO;2-H&rft_dat=%3Cproquest_cross%3E69590761%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69590761&rft_id=info:pmid/10030647&rfr_iscdi=true