Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences

Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐plan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2008-08, Vol.28 (2), p.411-419
Hauptverfasser: Girometti, Rossano, Furlan, Alessandro, Esposito, Gennaro, Bazzocchi, Massimo, Como, Giuseppe, Soldano, Franca, Isola, Miriam, Toniutto, Pierluigi, Zuiani, Chiara
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 419
container_issue 2
container_start_page 411
container_title Journal of magnetic resonance imaging
container_volume 28
creator Girometti, Rossano
Furlan, Alessandro
Esposito, Gennaro
Bazzocchi, Massimo
Como, Giuseppe
Soldano, Franca
Isola, Miriam
Toniutto, Pierluigi
Zuiani, Chiara
description Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐planar sequences were acquired using sets of increasing b‐values: 0, 150, 250, and 400 seconds/mm2 (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm2 (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise‐scaled single‐point ADCs were calculated for each sequence from b = 400 seconds/mm2. Results ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 ± 0.20 × 10−3mm2/second vs. 1.54 ± 0.12 × 10−3mm2/second; P < 0.0001) and DW2a (mean 0.91 ± 0.18 × 10−3mm2/second vs. 1.04 ± 0.18 × 10−3mm2/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise‐scaled single‐point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm2 (1.12 ± 0.27 × 10−3mm2/second vs. 1.13 ± 0.17 × 10−3mm2/second). Conclusion A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm2) rather than high (800 seconds/mm2) maximum b‐values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b‐values. J. Magn. Reson. Imaging 2008;28:411–419. © 2008 Wiley‐Liss, Inc.
doi_str_mv 10.1002/jmri.21461
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69391886</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69391886</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4671-6cfc7c4e89f6e7b8a040e6ad1cae6b09ee2ae8fca08aba570937abcb7c620f663</originalsourceid><addsrcrecordid>eNp9kc1u1DAUhSMEoqWw4QGQVyyQ3Nr5sR12VQWlqC1SC0JiY9nOdeMhk0x9kxnmhXjOOp0Bdmyuz-I75175ZNlrzo45Y_nJYhnDcc5LwZ9kh7zKc5pXSjxNmlUF5YrJg-wF4oIxVtdl9Tw74EoIwYv6MPt9Ax2sTe-ADJ5YujbdBEhCT2CWZgz9HenCGiLxwcYBA74npwTHqdnOVAumG9stMX1DXIixHcbgCE52AW5EMuHsHzcDmUUHFBNAcBV6Cq4dyDzoqjO9iaQJ3id-6OkGwl07QkMQ7idIt-HL7Jk3HcKr_XuUffv44evZJ3r55fzi7PSSulJIToXzTroSVO0FSKsMKxkI03BnQFhWA-QGlHeGKWNNJVldSGOdlU7kzAtRHGVvd7mrOKTVOOplQAdduhCGCbWoi5orNYPvdqBLf4IRvF7FsDRxqznTcyt6bkU_tpLgN_vUyS6h-Yfua0gA3wGb0MH2P1H689XNxZ9QuvMEHOHXX4-JP7WQhaz09-tz_eOKl7fyttaseADci6wz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69391886</pqid></control><display><type>article</type><title>Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Wiley Free Content</source><creator>Girometti, Rossano ; Furlan, Alessandro ; Esposito, Gennaro ; Bazzocchi, Massimo ; Como, Giuseppe ; Soldano, Franca ; Isola, Miriam ; Toniutto, Pierluigi ; Zuiani, Chiara</creator><creatorcontrib>Girometti, Rossano ; Furlan, Alessandro ; Esposito, Gennaro ; Bazzocchi, Massimo ; Como, Giuseppe ; Soldano, Franca ; Isola, Miriam ; Toniutto, Pierluigi ; Zuiani, Chiara</creatorcontrib><description>Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐planar sequences were acquired using sets of increasing b‐values: 0, 150, 250, and 400 seconds/mm2 (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm2 (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise‐scaled single‐point ADCs were calculated for each sequence from b = 400 seconds/mm2. Results ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 ± 0.20 × 10−3mm2/second vs. 1.54 ± 0.12 × 10−3mm2/second; P &lt; 0.0001) and DW2a (mean 0.91 ± 0.18 × 10−3mm2/second vs. 1.04 ± 0.18 × 10−3mm2/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise‐scaled single‐point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm2 (1.12 ± 0.27 × 10−3mm2/second vs. 1.13 ± 0.17 × 10−3mm2/second). Conclusion A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm2) rather than high (800 seconds/mm2) maximum b‐values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b‐values. J. Magn. Reson. Imaging 2008;28:411–419. © 2008 Wiley‐Liss, Inc.</description><identifier>ISSN: 1053-1807</identifier><identifier>EISSN: 1522-2586</identifier><identifier>DOI: 10.1002/jmri.21461</identifier><identifier>PMID: 18666139</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Adult ; Aged ; Analysis of Variance ; Area Under Curve ; b-values ; Case-Control Studies ; Contrast Media ; Diffusion Magnetic Resonance Imaging - methods ; diffusion-weighted MRI ; Echo-Planar Imaging ; Female ; Humans ; Image Interpretation, Computer-Assisted ; liver cirrhosis ; Liver Cirrhosis - pathology ; liver diseases ; liver fibrosis ; Male ; Meglumine - analogs &amp; derivatives ; Middle Aged ; Organometallic Compounds ; Phantoms, Imaging ; Prospective Studies ; ROC Curve ; Sensitivity and Specificity</subject><ispartof>Journal of magnetic resonance imaging, 2008-08, Vol.28 (2), p.411-419</ispartof><rights>Copyright © 2008 Wiley‐Liss, Inc.</rights><rights>(c) 2008 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4671-6cfc7c4e89f6e7b8a040e6ad1cae6b09ee2ae8fca08aba570937abcb7c620f663</citedby><cites>FETCH-LOGICAL-c4671-6cfc7c4e89f6e7b8a040e6ad1cae6b09ee2ae8fca08aba570937abcb7c620f663</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjmri.21461$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjmri.21461$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,1427,27903,27904,45553,45554,46387,46811</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18666139$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Girometti, Rossano</creatorcontrib><creatorcontrib>Furlan, Alessandro</creatorcontrib><creatorcontrib>Esposito, Gennaro</creatorcontrib><creatorcontrib>Bazzocchi, Massimo</creatorcontrib><creatorcontrib>Como, Giuseppe</creatorcontrib><creatorcontrib>Soldano, Franca</creatorcontrib><creatorcontrib>Isola, Miriam</creatorcontrib><creatorcontrib>Toniutto, Pierluigi</creatorcontrib><creatorcontrib>Zuiani, Chiara</creatorcontrib><title>Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences</title><title>Journal of magnetic resonance imaging</title><addtitle>J. Magn. Reson. Imaging</addtitle><description>Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐planar sequences were acquired using sets of increasing b‐values: 0, 150, 250, and 400 seconds/mm2 (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm2 (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise‐scaled single‐point ADCs were calculated for each sequence from b = 400 seconds/mm2. Results ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 ± 0.20 × 10−3mm2/second vs. 1.54 ± 0.12 × 10−3mm2/second; P &lt; 0.0001) and DW2a (mean 0.91 ± 0.18 × 10−3mm2/second vs. 1.04 ± 0.18 × 10−3mm2/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise‐scaled single‐point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm2 (1.12 ± 0.27 × 10−3mm2/second vs. 1.13 ± 0.17 × 10−3mm2/second). Conclusion A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm2) rather than high (800 seconds/mm2) maximum b‐values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b‐values. J. Magn. Reson. Imaging 2008;28:411–419. © 2008 Wiley‐Liss, Inc.</description><subject>Adult</subject><subject>Aged</subject><subject>Analysis of Variance</subject><subject>Area Under Curve</subject><subject>b-values</subject><subject>Case-Control Studies</subject><subject>Contrast Media</subject><subject>Diffusion Magnetic Resonance Imaging - methods</subject><subject>diffusion-weighted MRI</subject><subject>Echo-Planar Imaging</subject><subject>Female</subject><subject>Humans</subject><subject>Image Interpretation, Computer-Assisted</subject><subject>liver cirrhosis</subject><subject>Liver Cirrhosis - pathology</subject><subject>liver diseases</subject><subject>liver fibrosis</subject><subject>Male</subject><subject>Meglumine - analogs &amp; derivatives</subject><subject>Middle Aged</subject><subject>Organometallic Compounds</subject><subject>Phantoms, Imaging</subject><subject>Prospective Studies</subject><subject>ROC Curve</subject><subject>Sensitivity and Specificity</subject><issn>1053-1807</issn><issn>1522-2586</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc1u1DAUhSMEoqWw4QGQVyyQ3Nr5sR12VQWlqC1SC0JiY9nOdeMhk0x9kxnmhXjOOp0Bdmyuz-I75175ZNlrzo45Y_nJYhnDcc5LwZ9kh7zKc5pXSjxNmlUF5YrJg-wF4oIxVtdl9Tw74EoIwYv6MPt9Ax2sTe-ADJ5YujbdBEhCT2CWZgz9HenCGiLxwcYBA74npwTHqdnOVAumG9stMX1DXIixHcbgCE52AW5EMuHsHzcDmUUHFBNAcBV6Cq4dyDzoqjO9iaQJ3id-6OkGwl07QkMQ7idIt-HL7Jk3HcKr_XuUffv44evZJ3r55fzi7PSSulJIToXzTroSVO0FSKsMKxkI03BnQFhWA-QGlHeGKWNNJVldSGOdlU7kzAtRHGVvd7mrOKTVOOplQAdduhCGCbWoi5orNYPvdqBLf4IRvF7FsDRxqznTcyt6bkU_tpLgN_vUyS6h-Yfua0gA3wGb0MH2P1H689XNxZ9QuvMEHOHXX4-JP7WQhaz09-tz_eOKl7fyttaseADci6wz</recordid><startdate>200808</startdate><enddate>200808</enddate><creator>Girometti, Rossano</creator><creator>Furlan, Alessandro</creator><creator>Esposito, Gennaro</creator><creator>Bazzocchi, Massimo</creator><creator>Como, Giuseppe</creator><creator>Soldano, Franca</creator><creator>Isola, Miriam</creator><creator>Toniutto, Pierluigi</creator><creator>Zuiani, Chiara</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200808</creationdate><title>Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences</title><author>Girometti, Rossano ; Furlan, Alessandro ; Esposito, Gennaro ; Bazzocchi, Massimo ; Como, Giuseppe ; Soldano, Franca ; Isola, Miriam ; Toniutto, Pierluigi ; Zuiani, Chiara</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4671-6cfc7c4e89f6e7b8a040e6ad1cae6b09ee2ae8fca08aba570937abcb7c620f663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Analysis of Variance</topic><topic>Area Under Curve</topic><topic>b-values</topic><topic>Case-Control Studies</topic><topic>Contrast Media</topic><topic>Diffusion Magnetic Resonance Imaging - methods</topic><topic>diffusion-weighted MRI</topic><topic>Echo-Planar Imaging</topic><topic>Female</topic><topic>Humans</topic><topic>Image Interpretation, Computer-Assisted</topic><topic>liver cirrhosis</topic><topic>Liver Cirrhosis - pathology</topic><topic>liver diseases</topic><topic>liver fibrosis</topic><topic>Male</topic><topic>Meglumine - analogs &amp; derivatives</topic><topic>Middle Aged</topic><topic>Organometallic Compounds</topic><topic>Phantoms, Imaging</topic><topic>Prospective Studies</topic><topic>ROC Curve</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Girometti, Rossano</creatorcontrib><creatorcontrib>Furlan, Alessandro</creatorcontrib><creatorcontrib>Esposito, Gennaro</creatorcontrib><creatorcontrib>Bazzocchi, Massimo</creatorcontrib><creatorcontrib>Como, Giuseppe</creatorcontrib><creatorcontrib>Soldano, Franca</creatorcontrib><creatorcontrib>Isola, Miriam</creatorcontrib><creatorcontrib>Toniutto, Pierluigi</creatorcontrib><creatorcontrib>Zuiani, Chiara</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Girometti, Rossano</au><au>Furlan, Alessandro</au><au>Esposito, Gennaro</au><au>Bazzocchi, Massimo</au><au>Como, Giuseppe</au><au>Soldano, Franca</au><au>Isola, Miriam</au><au>Toniutto, Pierluigi</au><au>Zuiani, Chiara</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences</atitle><jtitle>Journal of magnetic resonance imaging</jtitle><addtitle>J. Magn. Reson. Imaging</addtitle><date>2008-08</date><risdate>2008</risdate><volume>28</volume><issue>2</issue><spage>411</spage><epage>419</epage><pages>411-419</pages><issn>1053-1807</issn><eissn>1522-2586</eissn><abstract>Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐planar sequences were acquired using sets of increasing b‐values: 0, 150, 250, and 400 seconds/mm2 (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm2 (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise‐scaled single‐point ADCs were calculated for each sequence from b = 400 seconds/mm2. Results ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 ± 0.20 × 10−3mm2/second vs. 1.54 ± 0.12 × 10−3mm2/second; P &lt; 0.0001) and DW2a (mean 0.91 ± 0.18 × 10−3mm2/second vs. 1.04 ± 0.18 × 10−3mm2/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise‐scaled single‐point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm2 (1.12 ± 0.27 × 10−3mm2/second vs. 1.13 ± 0.17 × 10−3mm2/second). Conclusion A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm2) rather than high (800 seconds/mm2) maximum b‐values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b‐values. J. Magn. Reson. Imaging 2008;28:411–419. © 2008 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>18666139</pmid><doi>10.1002/jmri.21461</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1053-1807
ispartof Journal of magnetic resonance imaging, 2008-08, Vol.28 (2), p.411-419
issn 1053-1807
1522-2586
language eng
recordid cdi_proquest_miscellaneous_69391886
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Wiley Free Content
subjects Adult
Aged
Analysis of Variance
Area Under Curve
b-values
Case-Control Studies
Contrast Media
Diffusion Magnetic Resonance Imaging - methods
diffusion-weighted MRI
Echo-Planar Imaging
Female
Humans
Image Interpretation, Computer-Assisted
liver cirrhosis
Liver Cirrhosis - pathology
liver diseases
liver fibrosis
Male
Meglumine - analogs & derivatives
Middle Aged
Organometallic Compounds
Phantoms, Imaging
Prospective Studies
ROC Curve
Sensitivity and Specificity
title Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T14%3A11%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relevance%20of%20b-values%20in%20evaluating%20liver%20fibrosis:%20A%20study%20in%20healthy%20and%20cirrhotic%20subjects%20using%20two%20single-shot%20spin-echo%20echo-planar%20diffusion-weighted%20sequences&rft.jtitle=Journal%20of%20magnetic%20resonance%20imaging&rft.au=Girometti,%20Rossano&rft.date=2008-08&rft.volume=28&rft.issue=2&rft.spage=411&rft.epage=419&rft.pages=411-419&rft.issn=1053-1807&rft.eissn=1522-2586&rft_id=info:doi/10.1002/jmri.21461&rft_dat=%3Cproquest_cross%3E69391886%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69391886&rft_id=info:pmid/18666139&rfr_iscdi=true