Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry
Pharmaceutical counterfeiting has become a significant public health problem worldwide and new, rapid, user-friendly, reliable and inexpensive methods for drug quality screening are needed. This work illustrates the chemical characterization of genuine and fake artesunate antimalarial tablets by por...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2008-08, Vol.623 (2), p.178-186 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 186 |
---|---|
container_issue | 2 |
container_start_page | 178 |
container_title | Analytica chimica acta |
container_volume | 623 |
creator | Ricci, Camilla Nyadong, Leonard Yang, Felicia Fernandez, Facundo M. Brown, Christopher D. Newton, Paul N. Kazarian, Sergei G. |
description | Pharmaceutical counterfeiting has become a significant public health problem worldwide and new, rapid, user-friendly, reliable and inexpensive methods for drug quality screening are needed. This work illustrates the chemical characterization of genuine and fake artesunate antimalarial tablets by portable Raman spectroscopy and validation by FT-Raman spectroscopy and ambient mass spectrometry. The applicability of a compact and robust portable Raman spectrometer (TruScan™) for the
in situ chemical identification of counterfeit tablets is reported. |
doi_str_mv | 10.1016/j.aca.2008.06.007 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69318839</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267008011318</els_id><sourcerecordid>69318839</sourcerecordid><originalsourceid>FETCH-LOGICAL-c509t-3d4113a02b7995c8aa252a3c5c37d3c74a9597a297bb810453c117023da283c13</originalsourceid><addsrcrecordid>eNqFkstu1TAQhiMEoofCA7BB3sAuB19ys1hVFS1IlZBQWVsTZ0J9lDjB41QKT8ej4dMcYEdXtmc-z4z--bPsteB7wUX1_rAHC3vJebPn1Z7z-km2E02t8kLJ4mm245yrXFY1P8teEB3SUwpePM_ORFNJrqXcZb8uiJBoRB_Z1LM78F1-h0PHvsIInjlPMSzHLEQ3edZPIcUYubgwsgHRO__9ITpPMVEOhmFldlp8xNCjiwxCRFo8RGSQ8iMMEBLFIrQDRmLtyq5u860bzWhjmMhO85rojnUupAhLnd3PbYARiP5wI8awvsye9TAQvjqd59m3q4-3l5_ymy_Xny8vbnJbch1z1RVCKOCyrbUubQMgSwnKllbVnbJ1AbrUNUhdt22TRCqVFaLmUnUgm3RX59m7re4cph8LUjSjI4vDAB6nhUyllWgapR8FVcFVoariUVDoSqct1wkUG2iTNhSwN3NIQobVCG6ORjAHk4xgjkYwvDLJCOnPm1PxpR2x-_fjtPkEvD0BQBaGPoC3jv5ykpdClqpK3IeNwyTuvcNgyDr0FrfdmG5y_xnjN9Fz1Nw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19690167</pqid></control><display><type>article</type><title>Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Ricci, Camilla ; Nyadong, Leonard ; Yang, Felicia ; Fernandez, Facundo M. ; Brown, Christopher D. ; Newton, Paul N. ; Kazarian, Sergei G.</creator><creatorcontrib>Ricci, Camilla ; Nyadong, Leonard ; Yang, Felicia ; Fernandez, Facundo M. ; Brown, Christopher D. ; Newton, Paul N. ; Kazarian, Sergei G.</creatorcontrib><description>Pharmaceutical counterfeiting has become a significant public health problem worldwide and new, rapid, user-friendly, reliable and inexpensive methods for drug quality screening are needed. This work illustrates the chemical characterization of genuine and fake artesunate antimalarial tablets by portable Raman spectroscopy and validation by FT-Raman spectroscopy and ambient mass spectrometry. The applicability of a compact and robust portable Raman spectrometer (TruScan™) for the
in situ chemical identification of counterfeit tablets is reported.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2008.06.007</identifier><identifier>PMID: 18620922</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Antimalarials - analysis ; Artemisinins - analysis ; Chemistry ; Counterfeit drugs ; Desorption electrospray ionization ; Direct analysis in real-time ; Exact sciences and technology ; Fourier Analysis ; Fraud ; General, instrumentation ; Malaria ; Mass spectrometry ; Mass Spectrometry - methods ; Portable Raman spectroscopy ; Quality Control ; Reproducibility of Results ; Spectrometric and optical methods ; Spectrum Analysis, Raman - instrumentation ; Tablets</subject><ispartof>Analytica chimica acta, 2008-08, Vol.623 (2), p.178-186</ispartof><rights>2008 Elsevier B.V.</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c509t-3d4113a02b7995c8aa252a3c5c37d3c74a9597a297bb810453c117023da283c13</citedby><cites>FETCH-LOGICAL-c509t-3d4113a02b7995c8aa252a3c5c37d3c74a9597a297bb810453c117023da283c13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0003267008011318$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20512536$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18620922$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ricci, Camilla</creatorcontrib><creatorcontrib>Nyadong, Leonard</creatorcontrib><creatorcontrib>Yang, Felicia</creatorcontrib><creatorcontrib>Fernandez, Facundo M.</creatorcontrib><creatorcontrib>Brown, Christopher D.</creatorcontrib><creatorcontrib>Newton, Paul N.</creatorcontrib><creatorcontrib>Kazarian, Sergei G.</creatorcontrib><title>Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>Pharmaceutical counterfeiting has become a significant public health problem worldwide and new, rapid, user-friendly, reliable and inexpensive methods for drug quality screening are needed. This work illustrates the chemical characterization of genuine and fake artesunate antimalarial tablets by portable Raman spectroscopy and validation by FT-Raman spectroscopy and ambient mass spectrometry. The applicability of a compact and robust portable Raman spectrometer (TruScan™) for the
in situ chemical identification of counterfeit tablets is reported.</description><subject>Analytical chemistry</subject><subject>Antimalarials - analysis</subject><subject>Artemisinins - analysis</subject><subject>Chemistry</subject><subject>Counterfeit drugs</subject><subject>Desorption electrospray ionization</subject><subject>Direct analysis in real-time</subject><subject>Exact sciences and technology</subject><subject>Fourier Analysis</subject><subject>Fraud</subject><subject>General, instrumentation</subject><subject>Malaria</subject><subject>Mass spectrometry</subject><subject>Mass Spectrometry - methods</subject><subject>Portable Raman spectroscopy</subject><subject>Quality Control</subject><subject>Reproducibility of Results</subject><subject>Spectrometric and optical methods</subject><subject>Spectrum Analysis, Raman - instrumentation</subject><subject>Tablets</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkstu1TAQhiMEoofCA7BB3sAuB19ys1hVFS1IlZBQWVsTZ0J9lDjB41QKT8ej4dMcYEdXtmc-z4z--bPsteB7wUX1_rAHC3vJebPn1Z7z-km2E02t8kLJ4mm245yrXFY1P8teEB3SUwpePM_ORFNJrqXcZb8uiJBoRB_Z1LM78F1-h0PHvsIInjlPMSzHLEQ3edZPIcUYubgwsgHRO__9ITpPMVEOhmFldlp8xNCjiwxCRFo8RGSQ8iMMEBLFIrQDRmLtyq5u860bzWhjmMhO85rojnUupAhLnd3PbYARiP5wI8awvsye9TAQvjqd59m3q4-3l5_ymy_Xny8vbnJbch1z1RVCKOCyrbUubQMgSwnKllbVnbJ1AbrUNUhdt22TRCqVFaLmUnUgm3RX59m7re4cph8LUjSjI4vDAB6nhUyllWgapR8FVcFVoariUVDoSqct1wkUG2iTNhSwN3NIQobVCG6ORjAHk4xgjkYwvDLJCOnPm1PxpR2x-_fjtPkEvD0BQBaGPoC3jv5ykpdClqpK3IeNwyTuvcNgyDr0FrfdmG5y_xnjN9Fz1Nw</recordid><startdate>20080815</startdate><enddate>20080815</enddate><creator>Ricci, Camilla</creator><creator>Nyadong, Leonard</creator><creator>Yang, Felicia</creator><creator>Fernandez, Facundo M.</creator><creator>Brown, Christopher D.</creator><creator>Newton, Paul N.</creator><creator>Kazarian, Sergei G.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>M7N</scope><scope>P64</scope><scope>7U5</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20080815</creationdate><title>Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry</title><author>Ricci, Camilla ; Nyadong, Leonard ; Yang, Felicia ; Fernandez, Facundo M. ; Brown, Christopher D. ; Newton, Paul N. ; Kazarian, Sergei G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c509t-3d4113a02b7995c8aa252a3c5c37d3c74a9597a297bb810453c117023da283c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Analytical chemistry</topic><topic>Antimalarials - analysis</topic><topic>Artemisinins - analysis</topic><topic>Chemistry</topic><topic>Counterfeit drugs</topic><topic>Desorption electrospray ionization</topic><topic>Direct analysis in real-time</topic><topic>Exact sciences and technology</topic><topic>Fourier Analysis</topic><topic>Fraud</topic><topic>General, instrumentation</topic><topic>Malaria</topic><topic>Mass spectrometry</topic><topic>Mass Spectrometry - methods</topic><topic>Portable Raman spectroscopy</topic><topic>Quality Control</topic><topic>Reproducibility of Results</topic><topic>Spectrometric and optical methods</topic><topic>Spectrum Analysis, Raman - instrumentation</topic><topic>Tablets</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ricci, Camilla</creatorcontrib><creatorcontrib>Nyadong, Leonard</creatorcontrib><creatorcontrib>Yang, Felicia</creatorcontrib><creatorcontrib>Fernandez, Facundo M.</creatorcontrib><creatorcontrib>Brown, Christopher D.</creatorcontrib><creatorcontrib>Newton, Paul N.</creatorcontrib><creatorcontrib>Kazarian, Sergei G.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ricci, Camilla</au><au>Nyadong, Leonard</au><au>Yang, Felicia</au><au>Fernandez, Facundo M.</au><au>Brown, Christopher D.</au><au>Newton, Paul N.</au><au>Kazarian, Sergei G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2008-08-15</date><risdate>2008</risdate><volume>623</volume><issue>2</issue><spage>178</spage><epage>186</epage><pages>178-186</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>Pharmaceutical counterfeiting has become a significant public health problem worldwide and new, rapid, user-friendly, reliable and inexpensive methods for drug quality screening are needed. This work illustrates the chemical characterization of genuine and fake artesunate antimalarial tablets by portable Raman spectroscopy and validation by FT-Raman spectroscopy and ambient mass spectrometry. The applicability of a compact and robust portable Raman spectrometer (TruScan™) for the
in situ chemical identification of counterfeit tablets is reported.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>18620922</pmid><doi>10.1016/j.aca.2008.06.007</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2670 |
ispartof | Analytica chimica acta, 2008-08, Vol.623 (2), p.178-186 |
issn | 0003-2670 1873-4324 |
language | eng |
recordid | cdi_proquest_miscellaneous_69318839 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Analytical chemistry Antimalarials - analysis Artemisinins - analysis Chemistry Counterfeit drugs Desorption electrospray ionization Direct analysis in real-time Exact sciences and technology Fourier Analysis Fraud General, instrumentation Malaria Mass spectrometry Mass Spectrometry - methods Portable Raman spectroscopy Quality Control Reproducibility of Results Spectrometric and optical methods Spectrum Analysis, Raman - instrumentation Tablets |
title | Assessment of hand-held Raman instrumentation for in situ screening for potentially counterfeit artesunate antimalarial tablets by FT-Raman spectroscopy and direct ionization mass spectrometry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T18%3A09%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20hand-held%20Raman%20instrumentation%20for%20in%20situ%20screening%20for%20potentially%20counterfeit%20artesunate%20antimalarial%20tablets%20by%20FT-Raman%20spectroscopy%20and%20direct%20ionization%20mass%20spectrometry&rft.jtitle=Analytica%20chimica%20acta&rft.au=Ricci,%20Camilla&rft.date=2008-08-15&rft.volume=623&rft.issue=2&rft.spage=178&rft.epage=186&rft.pages=178-186&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2008.06.007&rft_dat=%3Cproquest_cross%3E69318839%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=19690167&rft_id=info:pmid/18620922&rft_els_id=S0003267008011318&rfr_iscdi=true |