Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently

BackgroundArchived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been st...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of bone and joint surgery. American volume 2008-07, Vol.90 (7), p.1543-1552
Hauptverfasser: Collier, Matthew B, Engh, C Anderson, Hatten, Kyle M, Ginn, Stuart D, Sheils, Todd M, Engh, Gerard A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1552
container_issue 7
container_start_page 1543
container_title Journal of bone and joint surgery. American volume
container_volume 90
creator Collier, Matthew B
Engh, C Anderson
Hatten, Kyle M
Ginn, Stuart D
Sheils, Todd M
Engh, Gerard A
description BackgroundArchived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently.MethodsFour hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness over time. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment.ResultsAccording to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of >1 mm, and no nonirradiated insert showed a loss of >2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p < 0.01).ConclusionsIn this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an in
doi_str_mv 10.2106/JBJS.G.00651
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69281168</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69281168</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3647-8ebfc8c79ab2720fcd4fa82ae252be32986c55298f98412546de696e843fb3153</originalsourceid><addsrcrecordid>eNpF0c9v0zAUB3ALMbEyuHFGvsCJFNuxHee4X3SbKoHYOEeO80zMnKT4pZrKX49Lq3Gwnvz00dfS14S842wpONOf7y7u7perJWNa8RdkwVWpCl4a_ZIsGBO8qEulTslrxF-MMSlZ9YqccqNqyZlcEPxuuzD9THbTB0fPEQFxgHGmk6dzD_Qhrx_HvKTrCWfq0zTQb1PcwdzvIowZhDbYSG9HhDRj9namN7ajFwAjvZ8hhRj-QEevgveQcnLcvSEn3kaEt8d5Rn58uX64vCnWX1e3l-frwpVaVoWB1jvjqtq2ohLMu056a4QFoUQLpaiNdkrl4WsjuVBSd6BrDUaWvi1zD2fk4yF3k6bfW8C5GQI6iNGOMG2x0bUwnGuT4acDdGlCTOCbTQqDTbuGs2ZfcrMvuVk1_0rO_P0xd9sO0P3Hx1Yz-HAEFp2NPtnRBXx2gldKaL138uCeppibwse4fYLU9GDj3OfH8n9pURaCMcOqfCvy4VX5F2UilMM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69281168</pqid></control><display><type>article</type><title>Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Collier, Matthew B ; Engh, C Anderson ; Hatten, Kyle M ; Ginn, Stuart D ; Sheils, Todd M ; Engh, Gerard A</creator><creatorcontrib>Collier, Matthew B ; Engh, C Anderson ; Hatten, Kyle M ; Ginn, Stuart D ; Sheils, Todd M ; Engh, Gerard A</creatorcontrib><description>BackgroundArchived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently.MethodsFour hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness over time. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment.ResultsAccording to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of &gt;1 mm, and no nonirradiated insert showed a loss of &gt;2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p &lt; 0.01).ConclusionsIn this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an inert gas may oxidize in vivo and develop fatigue wear because of free radicals generated during sterilization with radiation and that nonirradiated bearings may undergo greater losses in thickness from routine burnishing since they lack the cross-linking that accompanies sterilization with radiation.Level of EvidenceTherapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.</description><identifier>ISSN: 0021-9355</identifier><identifier>EISSN: 1535-1386</identifier><identifier>DOI: 10.2106/JBJS.G.00651</identifier><identifier>PMID: 18594104</identifier><identifier>CODEN: JBJSA3</identifier><language>eng</language><publisher>Boston, MA: Copyright by The Journal of Bone and Joint Surgery, Incorporated</publisher><subject>Aged ; Arthroplasty, Replacement, Knee ; Biocompatible Materials ; Biological and medical sciences ; Diseases of the osteoarticular system ; Female ; Follow-Up Studies ; Humans ; Joint Prosthesis ; Knee Joint - diagnostic imaging ; Male ; Medical sciences ; Middle Aged ; Orthopedic surgery ; Osteoarthritis, Knee - surgery ; Polyethylene ; Prosthesis Failure ; Radiography ; Sterilization ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><ispartof>Journal of bone and joint surgery. American volume, 2008-07, Vol.90 (7), p.1543-1552</ispartof><rights>Copyright 2008 by The Journal of Bone and Joint Surgery, Incorporated</rights><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3647-8ebfc8c79ab2720fcd4fa82ae252be32986c55298f98412546de696e843fb3153</citedby><cites>FETCH-LOGICAL-c3647-8ebfc8c79ab2720fcd4fa82ae252be32986c55298f98412546de696e843fb3153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=21752664$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18594104$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Collier, Matthew B</creatorcontrib><creatorcontrib>Engh, C Anderson</creatorcontrib><creatorcontrib>Hatten, Kyle M</creatorcontrib><creatorcontrib>Ginn, Stuart D</creatorcontrib><creatorcontrib>Sheils, Todd M</creatorcontrib><creatorcontrib>Engh, Gerard A</creatorcontrib><title>Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently</title><title>Journal of bone and joint surgery. American volume</title><addtitle>J Bone Joint Surg Am</addtitle><description>BackgroundArchived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently.MethodsFour hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness over time. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment.ResultsAccording to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of &gt;1 mm, and no nonirradiated insert showed a loss of &gt;2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p &lt; 0.01).ConclusionsIn this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an inert gas may oxidize in vivo and develop fatigue wear because of free radicals generated during sterilization with radiation and that nonirradiated bearings may undergo greater losses in thickness from routine burnishing since they lack the cross-linking that accompanies sterilization with radiation.Level of EvidenceTherapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.</description><subject>Aged</subject><subject>Arthroplasty, Replacement, Knee</subject><subject>Biocompatible Materials</subject><subject>Biological and medical sciences</subject><subject>Diseases of the osteoarticular system</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Humans</subject><subject>Joint Prosthesis</subject><subject>Knee Joint - diagnostic imaging</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Orthopedic surgery</subject><subject>Osteoarthritis, Knee - surgery</subject><subject>Polyethylene</subject><subject>Prosthesis Failure</subject><subject>Radiography</subject><subject>Sterilization</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><issn>0021-9355</issn><issn>1535-1386</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0c9v0zAUB3ALMbEyuHFGvsCJFNuxHee4X3SbKoHYOEeO80zMnKT4pZrKX49Lq3Gwnvz00dfS14S842wpONOf7y7u7perJWNa8RdkwVWpCl4a_ZIsGBO8qEulTslrxF-MMSlZ9YqccqNqyZlcEPxuuzD9THbTB0fPEQFxgHGmk6dzD_Qhrx_HvKTrCWfq0zTQb1PcwdzvIowZhDbYSG9HhDRj9namN7ajFwAjvZ8hhRj-QEevgveQcnLcvSEn3kaEt8d5Rn58uX64vCnWX1e3l-frwpVaVoWB1jvjqtq2ohLMu056a4QFoUQLpaiNdkrl4WsjuVBSd6BrDUaWvi1zD2fk4yF3k6bfW8C5GQI6iNGOMG2x0bUwnGuT4acDdGlCTOCbTQqDTbuGs2ZfcrMvuVk1_0rO_P0xd9sO0P3Hx1Yz-HAEFp2NPtnRBXx2gldKaL138uCeppibwse4fYLU9GDj3OfH8n9pURaCMcOqfCvy4VX5F2UilMM</recordid><startdate>20080701</startdate><enddate>20080701</enddate><creator>Collier, Matthew B</creator><creator>Engh, C Anderson</creator><creator>Hatten, Kyle M</creator><creator>Ginn, Stuart D</creator><creator>Sheils, Todd M</creator><creator>Engh, Gerard A</creator><general>Copyright by The Journal of Bone and Joint Surgery, Incorporated</general><general>Journal of Bone and Joint Surgery Incorporated</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20080701</creationdate><title>Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently</title><author>Collier, Matthew B ; Engh, C Anderson ; Hatten, Kyle M ; Ginn, Stuart D ; Sheils, Todd M ; Engh, Gerard A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3647-8ebfc8c79ab2720fcd4fa82ae252be32986c55298f98412546de696e843fb3153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Aged</topic><topic>Arthroplasty, Replacement, Knee</topic><topic>Biocompatible Materials</topic><topic>Biological and medical sciences</topic><topic>Diseases of the osteoarticular system</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Humans</topic><topic>Joint Prosthesis</topic><topic>Knee Joint - diagnostic imaging</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Orthopedic surgery</topic><topic>Osteoarthritis, Knee - surgery</topic><topic>Polyethylene</topic><topic>Prosthesis Failure</topic><topic>Radiography</topic><topic>Sterilization</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Collier, Matthew B</creatorcontrib><creatorcontrib>Engh, C Anderson</creatorcontrib><creatorcontrib>Hatten, Kyle M</creatorcontrib><creatorcontrib>Ginn, Stuart D</creatorcontrib><creatorcontrib>Sheils, Todd M</creatorcontrib><creatorcontrib>Engh, Gerard A</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of bone and joint surgery. American volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Collier, Matthew B</au><au>Engh, C Anderson</au><au>Hatten, Kyle M</au><au>Ginn, Stuart D</au><au>Sheils, Todd M</au><au>Engh, Gerard A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently</atitle><jtitle>Journal of bone and joint surgery. American volume</jtitle><addtitle>J Bone Joint Surg Am</addtitle><date>2008-07-01</date><risdate>2008</risdate><volume>90</volume><issue>7</issue><spage>1543</spage><epage>1552</epage><pages>1543-1552</pages><issn>0021-9355</issn><eissn>1535-1386</eissn><coden>JBJSA3</coden><abstract>BackgroundArchived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently.MethodsFour hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness over time. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment.ResultsAccording to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of &gt;1 mm, and no nonirradiated insert showed a loss of &gt;2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p &lt; 0.01).ConclusionsIn this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an inert gas may oxidize in vivo and develop fatigue wear because of free radicals generated during sterilization with radiation and that nonirradiated bearings may undergo greater losses in thickness from routine burnishing since they lack the cross-linking that accompanies sterilization with radiation.Level of EvidenceTherapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.</abstract><cop>Boston, MA</cop><pub>Copyright by The Journal of Bone and Joint Surgery, Incorporated</pub><pmid>18594104</pmid><doi>10.2106/JBJS.G.00651</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9355
ispartof Journal of bone and joint surgery. American volume, 2008-07, Vol.90 (7), p.1543-1552
issn 0021-9355
1535-1386
language eng
recordid cdi_proquest_miscellaneous_69281168
source MEDLINE; Alma/SFX Local Collection
subjects Aged
Arthroplasty, Replacement, Knee
Biocompatible Materials
Biological and medical sciences
Diseases of the osteoarticular system
Female
Follow-Up Studies
Humans
Joint Prosthesis
Knee Joint - diagnostic imaging
Male
Medical sciences
Middle Aged
Orthopedic surgery
Osteoarthritis, Knee - surgery
Polyethylene
Prosthesis Failure
Radiography
Sterilization
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
title Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T09%3A08%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiographic%20Assessment%20of%20the%20Thickness%20Lost%20from%20Polyethylene%20Tibial%20Inserts%20That%20Had%20Been%20Sterilized%20Differently&rft.jtitle=Journal%20of%20bone%20and%20joint%20surgery.%20American%20volume&rft.au=Collier,%20Matthew%20B&rft.date=2008-07-01&rft.volume=90&rft.issue=7&rft.spage=1543&rft.epage=1552&rft.pages=1543-1552&rft.issn=0021-9355&rft.eissn=1535-1386&rft.coden=JBJSA3&rft_id=info:doi/10.2106/JBJS.G.00651&rft_dat=%3Cproquest_cross%3E69281168%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69281168&rft_id=info:pmid/18594104&rfr_iscdi=true