Effect of silicone breast implants on myocardial imaging

The authors investigated the effect of silicone breast implants (SBIs) on thallium-201 myocardial perfusion scintigraphy. Twenty-nine patients with SBIs and 14 control subjects were included in the study. All of the participants underwent a resting thallium-201 myocardial perfusion study. Comparison...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of plastic surgery 1999-11, Vol.43 (5), p.471-475
Hauptverfasser: CANER, B, OZGUR, F, BOR, D, ULUTUNCEL, N, AYDIN, M, SARI, O
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 475
container_issue 5
container_start_page 471
container_title Annals of plastic surgery
container_volume 43
creator CANER, B
OZGUR, F
BOR, D
ULUTUNCEL, N
AYDIN, M
SARI, O
description The authors investigated the effect of silicone breast implants (SBIs) on thallium-201 myocardial perfusion scintigraphy. Twenty-nine patients with SBIs and 14 control subjects were included in the study. All of the participants underwent a resting thallium-201 myocardial perfusion study. Comparison of the thallium images between patients with SBI and control subjects was done both visually and semiquantitatively. On visual analysis, neither image distortion nor image artifact attributable to the SBIs was noted. Semiquantitative analysis revealed that in patients with SBIs, the uptake values of the anteroseptal, anterolateral, lateroanterior, and lateroinferior myocardial walls was slightly, but significantly, lower than those of control subjects: anteroseptal, 87.7+/-6.0% vs. 92.8+/-5.1%; anterolateral, 88.0+/-5% vs. 92.6+/-4.5%; lateroanterior, 87.4+/-5% vs. 91.4+/-4.7%; and lateroinferior, 86.0+/-6.0% vs. 91.7+/-7.0%. The uptake value of the remaining walls in patients with SBIs were not significantly different than the control subjects. In conclusion, SBIs did cause a significant decrease in uptake values of the myocardial walls, which should be considered during interpretation of the images.
doi_str_mv 10.1097/00000637-199911000-00002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69272084</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69272084</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-a46274822d09db0c51d982da24a6602730c31b1c70c7e6b880ef48e5f408082e3</originalsourceid><addsrcrecordid>eNpNkElPwzAQhS0EoqXwF1AOiFtgvMQeH1FVFqkSFzhHjmNXRlmKnRz670lpWeYymqdvZp4eIRmFOwpa3cO-JFc51VpTOg35XmEnZE4LLnOuAE_JHKjAXIHgM3KR0gcAZSjkOZlRKCSgpHOCK--dHbLeZyk0wfady6roTBqy0G4b0w0p67us3fXWxDqYZpLNJnSbS3LmTZPc1bEvyPvj6m35nK9fn16WD-vccgFDboRkSiBjNei6AlvQWiOrDRNGSmCKg-W0olaBVU5WiOC8QFd4AQjIHF-Q28Pdbew_R5eGsg3Jumay5voxlVIzxQDFBOIBtLFPKTpfbuPkNe5KCuU-tfIntfI3tW-JTavXxx9j1br63-Ihpgm4OQImWdP4aDob0h-nNWoJ_AvTOHKd</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69272084</pqid></control><display><type>article</type><title>Effect of silicone breast implants on myocardial imaging</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>CANER, B ; OZGUR, F ; BOR, D ; ULUTUNCEL, N ; AYDIN, M ; SARI, O</creator><creatorcontrib>CANER, B ; OZGUR, F ; BOR, D ; ULUTUNCEL, N ; AYDIN, M ; SARI, O</creatorcontrib><description>The authors investigated the effect of silicone breast implants (SBIs) on thallium-201 myocardial perfusion scintigraphy. Twenty-nine patients with SBIs and 14 control subjects were included in the study. All of the participants underwent a resting thallium-201 myocardial perfusion study. Comparison of the thallium images between patients with SBI and control subjects was done both visually and semiquantitatively. On visual analysis, neither image distortion nor image artifact attributable to the SBIs was noted. Semiquantitative analysis revealed that in patients with SBIs, the uptake values of the anteroseptal, anterolateral, lateroanterior, and lateroinferior myocardial walls was slightly, but significantly, lower than those of control subjects: anteroseptal, 87.7+/-6.0% vs. 92.8+/-5.1%; anterolateral, 88.0+/-5% vs. 92.6+/-4.5%; lateroanterior, 87.4+/-5% vs. 91.4+/-4.7%; and lateroinferior, 86.0+/-6.0% vs. 91.7+/-7.0%. The uptake value of the remaining walls in patients with SBIs were not significantly different than the control subjects. In conclusion, SBIs did cause a significant decrease in uptake values of the myocardial walls, which should be considered during interpretation of the images.</description><identifier>ISSN: 0148-7043</identifier><identifier>EISSN: 1536-3708</identifier><identifier>DOI: 10.1097/00000637-199911000-00002</identifier><identifier>PMID: 10560861</identifier><identifier>CODEN: APCSD4</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams &amp; Wilkins</publisher><subject>Adult ; Biological and medical sciences ; Breast Implants ; Endocrine glands. Genital system. Mammary gland ; Female ; Heart - diagnostic imaging ; Humans ; Image Interpretation, Computer-Assisted ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Radionuclide Imaging ; Radionuclide investigations ; Silicone Elastomers ; Sodium Chloride ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the genital tract and mammary gland ; Thallium Radioisotopes</subject><ispartof>Annals of plastic surgery, 1999-11, Vol.43 (5), p.471-475</ispartof><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-a46274822d09db0c51d982da24a6602730c31b1c70c7e6b880ef48e5f408082e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27928,27929</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1998960$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10560861$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>CANER, B</creatorcontrib><creatorcontrib>OZGUR, F</creatorcontrib><creatorcontrib>BOR, D</creatorcontrib><creatorcontrib>ULUTUNCEL, N</creatorcontrib><creatorcontrib>AYDIN, M</creatorcontrib><creatorcontrib>SARI, O</creatorcontrib><title>Effect of silicone breast implants on myocardial imaging</title><title>Annals of plastic surgery</title><addtitle>Ann Plast Surg</addtitle><description>The authors investigated the effect of silicone breast implants (SBIs) on thallium-201 myocardial perfusion scintigraphy. Twenty-nine patients with SBIs and 14 control subjects were included in the study. All of the participants underwent a resting thallium-201 myocardial perfusion study. Comparison of the thallium images between patients with SBI and control subjects was done both visually and semiquantitatively. On visual analysis, neither image distortion nor image artifact attributable to the SBIs was noted. Semiquantitative analysis revealed that in patients with SBIs, the uptake values of the anteroseptal, anterolateral, lateroanterior, and lateroinferior myocardial walls was slightly, but significantly, lower than those of control subjects: anteroseptal, 87.7+/-6.0% vs. 92.8+/-5.1%; anterolateral, 88.0+/-5% vs. 92.6+/-4.5%; lateroanterior, 87.4+/-5% vs. 91.4+/-4.7%; and lateroinferior, 86.0+/-6.0% vs. 91.7+/-7.0%. The uptake value of the remaining walls in patients with SBIs were not significantly different than the control subjects. In conclusion, SBIs did cause a significant decrease in uptake values of the myocardial walls, which should be considered during interpretation of the images.</description><subject>Adult</subject><subject>Biological and medical sciences</subject><subject>Breast Implants</subject><subject>Endocrine glands. Genital system. Mammary gland</subject><subject>Female</subject><subject>Heart - diagnostic imaging</subject><subject>Humans</subject><subject>Image Interpretation, Computer-Assisted</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Radionuclide Imaging</subject><subject>Radionuclide investigations</subject><subject>Silicone Elastomers</subject><subject>Sodium Chloride</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the genital tract and mammary gland</subject><subject>Thallium Radioisotopes</subject><issn>0148-7043</issn><issn>1536-3708</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkElPwzAQhS0EoqXwF1AOiFtgvMQeH1FVFqkSFzhHjmNXRlmKnRz670lpWeYymqdvZp4eIRmFOwpa3cO-JFc51VpTOg35XmEnZE4LLnOuAE_JHKjAXIHgM3KR0gcAZSjkOZlRKCSgpHOCK--dHbLeZyk0wfady6roTBqy0G4b0w0p67us3fXWxDqYZpLNJnSbS3LmTZPc1bEvyPvj6m35nK9fn16WD-vccgFDboRkSiBjNei6AlvQWiOrDRNGSmCKg-W0olaBVU5WiOC8QFd4AQjIHF-Q28Pdbew_R5eGsg3Jumay5voxlVIzxQDFBOIBtLFPKTpfbuPkNe5KCuU-tfIntfI3tW-JTavXxx9j1br63-Ihpgm4OQImWdP4aDob0h-nNWoJ_AvTOHKd</recordid><startdate>19991101</startdate><enddate>19991101</enddate><creator>CANER, B</creator><creator>OZGUR, F</creator><creator>BOR, D</creator><creator>ULUTUNCEL, N</creator><creator>AYDIN, M</creator><creator>SARI, O</creator><general>Lippincott Williams &amp; Wilkins</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19991101</creationdate><title>Effect of silicone breast implants on myocardial imaging</title><author>CANER, B ; OZGUR, F ; BOR, D ; ULUTUNCEL, N ; AYDIN, M ; SARI, O</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-a46274822d09db0c51d982da24a6602730c31b1c70c7e6b880ef48e5f408082e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Adult</topic><topic>Biological and medical sciences</topic><topic>Breast Implants</topic><topic>Endocrine glands. Genital system. Mammary gland</topic><topic>Female</topic><topic>Heart - diagnostic imaging</topic><topic>Humans</topic><topic>Image Interpretation, Computer-Assisted</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Radionuclide Imaging</topic><topic>Radionuclide investigations</topic><topic>Silicone Elastomers</topic><topic>Sodium Chloride</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the genital tract and mammary gland</topic><topic>Thallium Radioisotopes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>CANER, B</creatorcontrib><creatorcontrib>OZGUR, F</creatorcontrib><creatorcontrib>BOR, D</creatorcontrib><creatorcontrib>ULUTUNCEL, N</creatorcontrib><creatorcontrib>AYDIN, M</creatorcontrib><creatorcontrib>SARI, O</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of plastic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CANER, B</au><au>OZGUR, F</au><au>BOR, D</au><au>ULUTUNCEL, N</au><au>AYDIN, M</au><au>SARI, O</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of silicone breast implants on myocardial imaging</atitle><jtitle>Annals of plastic surgery</jtitle><addtitle>Ann Plast Surg</addtitle><date>1999-11-01</date><risdate>1999</risdate><volume>43</volume><issue>5</issue><spage>471</spage><epage>475</epage><pages>471-475</pages><issn>0148-7043</issn><eissn>1536-3708</eissn><coden>APCSD4</coden><abstract>The authors investigated the effect of silicone breast implants (SBIs) on thallium-201 myocardial perfusion scintigraphy. Twenty-nine patients with SBIs and 14 control subjects were included in the study. All of the participants underwent a resting thallium-201 myocardial perfusion study. Comparison of the thallium images between patients with SBI and control subjects was done both visually and semiquantitatively. On visual analysis, neither image distortion nor image artifact attributable to the SBIs was noted. Semiquantitative analysis revealed that in patients with SBIs, the uptake values of the anteroseptal, anterolateral, lateroanterior, and lateroinferior myocardial walls was slightly, but significantly, lower than those of control subjects: anteroseptal, 87.7+/-6.0% vs. 92.8+/-5.1%; anterolateral, 88.0+/-5% vs. 92.6+/-4.5%; lateroanterior, 87.4+/-5% vs. 91.4+/-4.7%; and lateroinferior, 86.0+/-6.0% vs. 91.7+/-7.0%. The uptake value of the remaining walls in patients with SBIs were not significantly different than the control subjects. In conclusion, SBIs did cause a significant decrease in uptake values of the myocardial walls, which should be considered during interpretation of the images.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams &amp; Wilkins</pub><pmid>10560861</pmid><doi>10.1097/00000637-199911000-00002</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0148-7043
ispartof Annals of plastic surgery, 1999-11, Vol.43 (5), p.471-475
issn 0148-7043
1536-3708
language eng
recordid cdi_proquest_miscellaneous_69272084
source MEDLINE; Journals@Ovid Complete
subjects Adult
Biological and medical sciences
Breast Implants
Endocrine glands. Genital system. Mammary gland
Female
Heart - diagnostic imaging
Humans
Image Interpretation, Computer-Assisted
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Radionuclide Imaging
Radionuclide investigations
Silicone Elastomers
Sodium Chloride
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the genital tract and mammary gland
Thallium Radioisotopes
title Effect of silicone breast implants on myocardial imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T01%3A39%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20silicone%20breast%20implants%20on%20myocardial%20imaging&rft.jtitle=Annals%20of%20plastic%20surgery&rft.au=CANER,%20B&rft.date=1999-11-01&rft.volume=43&rft.issue=5&rft.spage=471&rft.epage=475&rft.pages=471-475&rft.issn=0148-7043&rft.eissn=1536-3708&rft.coden=APCSD4&rft_id=info:doi/10.1097/00000637-199911000-00002&rft_dat=%3Cproquest_cross%3E69272084%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69272084&rft_id=info:pmid/10560861&rfr_iscdi=true