Biodegradable interlocking nails for fracture fixation
Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant t...
Gespeichert in:
Veröffentlicht in: | Clinical orthopaedics and related research 1998-12, Vol.357 (357), p.192-204 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 204 |
---|---|
container_issue | 357 |
container_start_page | 192 |
container_title | Clinical orthopaedics and related research |
container_volume | 357 |
creator | VAN DER ELST, M BRAMER, J. A. M KLEIN, C. P. A. T DE LANGE, E. S. M PATKA, P HAARMAN, H. J. T. M |
description | Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials. |
doi_str_mv | 10.1097/00003086-199812000-00025 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69147491</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69147491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-43fbcc3b1d994e64830033e16baae1ae973700dc11967a8ff3884948180818743</originalsourceid><addsrcrecordid>eNpFkEtLxDAQx4Mo67r6EYQexFs106R5HHXxBQteFLyFNE2WaB9r0oJ-e7NuXQeGYR7_meGHUAb4CrDk1zgZwYLlIKWAImV58qI8QHMoC5EDkOIQzVNN5rKAt2N0EuP7VkTLYoZmUgLnwOeI3fq-tuuga101NvPdYEPTmw_frbNO-yZmrg-ZC9oMY7CZ81968H13io6cbqI9m-ICvd7fvSwf89Xzw9PyZpUbwsSQU-IqY0gFtZTUMipI-oBYYJXWFrSVnHCMawMgGdfCOSIElVSAwMk5JQt0udu7Cf3naOOgWh-NbRrd2X6MikmgnEpIg2I3aEIfY7BObYJvdfhWgNUWmfpDpvbI1C-yJD2fboxVa-u9cGKU-hdTX0ejm8SiMz7-72e0pCUnP-Oichg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69147491</pqid></control><display><type>article</type><title>Biodegradable interlocking nails for fracture fixation</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>VAN DER ELST, M ; BRAMER, J. A. M ; KLEIN, C. P. A. T ; DE LANGE, E. S. M ; PATKA, P ; HAARMAN, H. J. T. M</creator><creatorcontrib>VAN DER ELST, M ; BRAMER, J. A. M ; KLEIN, C. P. A. T ; DE LANGE, E. S. M ; PATKA, P ; HAARMAN, H. J. T. M</creatorcontrib><description>Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-199812000-00025</identifier><identifier>PMID: 9917717</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Absorbable Implants ; Animals ; Biological and medical sciences ; Bone Nails ; Female ; Follow-Up Studies ; Fracture Fixation, Internal - instrumentation ; Fracture Healing ; Humans ; Hydrogen-Ion Concentration ; In Vitro Techniques ; Lactic Acid ; Medical sciences ; Polyesters ; Polymers ; Sheep ; Stainless Steel ; Stress, Mechanical ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Technology. Biomaterials. Equipments</subject><ispartof>Clinical orthopaedics and related research, 1998-12, Vol.357 (357), p.192-204</ispartof><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-43fbcc3b1d994e64830033e16baae1ae973700dc11967a8ff3884948180818743</citedby><cites>FETCH-LOGICAL-c368t-43fbcc3b1d994e64830033e16baae1ae973700dc11967a8ff3884948180818743</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1645457$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9917717$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>VAN DER ELST, M</creatorcontrib><creatorcontrib>BRAMER, J. A. M</creatorcontrib><creatorcontrib>KLEIN, C. P. A. T</creatorcontrib><creatorcontrib>DE LANGE, E. S. M</creatorcontrib><creatorcontrib>PATKA, P</creatorcontrib><creatorcontrib>HAARMAN, H. J. T. M</creatorcontrib><title>Biodegradable interlocking nails for fracture fixation</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials.</description><subject>Absorbable Implants</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Bone Nails</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Fracture Fixation, Internal - instrumentation</subject><subject>Fracture Healing</subject><subject>Humans</subject><subject>Hydrogen-Ion Concentration</subject><subject>In Vitro Techniques</subject><subject>Lactic Acid</subject><subject>Medical sciences</subject><subject>Polyesters</subject><subject>Polymers</subject><subject>Sheep</subject><subject>Stainless Steel</subject><subject>Stress, Mechanical</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Technology. Biomaterials. Equipments</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkEtLxDAQx4Mo67r6EYQexFs106R5HHXxBQteFLyFNE2WaB9r0oJ-e7NuXQeGYR7_meGHUAb4CrDk1zgZwYLlIKWAImV58qI8QHMoC5EDkOIQzVNN5rKAt2N0EuP7VkTLYoZmUgLnwOeI3fq-tuuga101NvPdYEPTmw_frbNO-yZmrg-ZC9oMY7CZ81968H13io6cbqI9m-ICvd7fvSwf89Xzw9PyZpUbwsSQU-IqY0gFtZTUMipI-oBYYJXWFrSVnHCMawMgGdfCOSIElVSAwMk5JQt0udu7Cf3naOOgWh-NbRrd2X6MikmgnEpIg2I3aEIfY7BObYJvdfhWgNUWmfpDpvbI1C-yJD2fboxVa-u9cGKU-hdTX0ejm8SiMz7-72e0pCUnP-Oichg</recordid><startdate>19981201</startdate><enddate>19981201</enddate><creator>VAN DER ELST, M</creator><creator>BRAMER, J. A. M</creator><creator>KLEIN, C. P. A. T</creator><creator>DE LANGE, E. S. M</creator><creator>PATKA, P</creator><creator>HAARMAN, H. J. T. M</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19981201</creationdate><title>Biodegradable interlocking nails for fracture fixation</title><author>VAN DER ELST, M ; BRAMER, J. A. M ; KLEIN, C. P. A. T ; DE LANGE, E. S. M ; PATKA, P ; HAARMAN, H. J. T. M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-43fbcc3b1d994e64830033e16baae1ae973700dc11967a8ff3884948180818743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Absorbable Implants</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Bone Nails</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Fracture Fixation, Internal - instrumentation</topic><topic>Fracture Healing</topic><topic>Humans</topic><topic>Hydrogen-Ion Concentration</topic><topic>In Vitro Techniques</topic><topic>Lactic Acid</topic><topic>Medical sciences</topic><topic>Polyesters</topic><topic>Polymers</topic><topic>Sheep</topic><topic>Stainless Steel</topic><topic>Stress, Mechanical</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Technology. Biomaterials. Equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>VAN DER ELST, M</creatorcontrib><creatorcontrib>BRAMER, J. A. M</creatorcontrib><creatorcontrib>KLEIN, C. P. A. T</creatorcontrib><creatorcontrib>DE LANGE, E. S. M</creatorcontrib><creatorcontrib>PATKA, P</creatorcontrib><creatorcontrib>HAARMAN, H. J. T. M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>VAN DER ELST, M</au><au>BRAMER, J. A. M</au><au>KLEIN, C. P. A. T</au><au>DE LANGE, E. S. M</au><au>PATKA, P</au><au>HAARMAN, H. J. T. M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biodegradable interlocking nails for fracture fixation</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1998-12-01</date><risdate>1998</risdate><volume>357</volume><issue>357</issue><spage>192</spage><epage>204</epage><pages>192-204</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>9917717</pmid><doi>10.1097/00003086-199812000-00025</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-921X |
ispartof | Clinical orthopaedics and related research, 1998-12, Vol.357 (357), p.192-204 |
issn | 0009-921X 1528-1132 |
language | eng |
recordid | cdi_proquest_miscellaneous_69147491 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Absorbable Implants Animals Biological and medical sciences Bone Nails Female Follow-Up Studies Fracture Fixation, Internal - instrumentation Fracture Healing Humans Hydrogen-Ion Concentration In Vitro Techniques Lactic Acid Medical sciences Polyesters Polymers Sheep Stainless Steel Stress, Mechanical Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Technology. Biomaterials. Equipments |
title | Biodegradable interlocking nails for fracture fixation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-12T16%3A53%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biodegradable%20interlocking%20nails%20for%20fracture%20fixation&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=VAN%20DER%20ELST,%20M&rft.date=1998-12-01&rft.volume=357&rft.issue=357&rft.spage=192&rft.epage=204&rft.pages=192-204&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-199812000-00025&rft_dat=%3Cproquest_cross%3E69147491%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69147491&rft_id=info:pmid/9917717&rfr_iscdi=true |