Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines

To examine the dependence of steady-state free-precession (SSFP) -based myocardial blood-oxygen-level-dependent (BOLD) contrast on field strength using theoretical and experimental models. Numerical simulations using a two-pool exchange model and a surgically prepared dog model were used to assess t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2008-05, Vol.27 (5), p.1037-1045
Hauptverfasser: Dharmakumar, Rohan, Arumana, Jain Mangalathu, Tang, Richard, Harris, Kathleen, Zhang, Zhouli, Li, Debiao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1045
container_issue 5
container_start_page 1037
container_title Journal of magnetic resonance imaging
container_volume 27
creator Dharmakumar, Rohan
Arumana, Jain Mangalathu
Tang, Richard
Harris, Kathleen
Zhang, Zhouli
Li, Debiao
description To examine the dependence of steady-state free-precession (SSFP) -based myocardial blood-oxygen-level-dependent (BOLD) contrast on field strength using theoretical and experimental models. Numerical simulations using a two-pool exchange model and a surgically prepared dog model were used to assess the SSFP-based myocardial BOLD signal changes at 1.5T and 3.0T. Experimental studies were performed in eight canines with pharmacological vasodilation under various levels of left circumflex coronary artery stenosis. Experimentally obtained BOLD signal changes were correlated against microsphere-based true flow changes. Theoretical results showed that, at 3.0T, relative to 1.5T, a threefold increase in oxygen sensitivity can be expected. Experimental studies in canines showed near similar results-a 2.5 +/- 0.2-fold increase in BOLD sensitivity at 3.0T relative to 1.5T (P < 0.05). Based on the scatter gram of BOLD data and microsphere data, it was found that the minimum regional flow difference that can be detected with SSFP-based myocardial BOLD imaging at 1.5T and 3.0T were 2.9 and 1.6, respectively (P < 0.05). This study demonstrated that SSFP-based myocardial BOLD sensitivity is substantially greater at 3.0T compared with 1.5T. The findings here suggest that SSFP-based myocardial BOLD imaging at 3.0T may have the necessary sensitivity to detect the clinically required minimum flow difference of 2.0.
doi_str_mv 10.1002/jmri.21345
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_69146910</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69146910</sourcerecordid><originalsourceid>FETCH-LOGICAL-p540-782c18ff6a902c60b85664abc43902a977b45c833338f73ef8ef393a07cf5b963</originalsourceid><addsrcrecordid>eNo1UMFOwzAMzQHExuDCB6CcuHWkTdqm3KaJARISSNu9SlO3y9QmJclg-y8-kFQblixb9nt-thG6i8k8JiR53PVWzZOYsvQCTWOS0ijmJJ-ga-d2hJCiYOkVmsScJSlnZIp-F86Bcz1oj02DLbTKaNHh_miksLUKqTkcW9DChwaWW6FbcFhp7LeABwsOtISRKo0NTHvEwnoIwXnQximHf5Tf4kp0IgBrvF6vPrHqRat0i4XHdE7w5mmcZkaurjEcBrBq3CiIw7fo9iftoCmFVhrcDbpsROfg9hxnaLN63ixfo_ePl7fl4j0aUkainCcy5k2TiYIkMiMVT7OMiUoyGgqiyPOKpZLTYLzJKTQcGlpQQXLZpFWR0Rl6OI0drPnag_Nlr5yELlwCZu_KrIhZcBKA92fgvuqhLoewfvhE-f9m-gfT5YAR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69146910</pqid></control><display><type>article</type><title>Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines</title><source>Wiley Online Library - AutoHoldings Journals</source><source>MEDLINE</source><source>Wiley Online Library (Open Access Collection)</source><creator>Dharmakumar, Rohan ; Arumana, Jain Mangalathu ; Tang, Richard ; Harris, Kathleen ; Zhang, Zhouli ; Li, Debiao</creator><creatorcontrib>Dharmakumar, Rohan ; Arumana, Jain Mangalathu ; Tang, Richard ; Harris, Kathleen ; Zhang, Zhouli ; Li, Debiao</creatorcontrib><description>To examine the dependence of steady-state free-precession (SSFP) -based myocardial blood-oxygen-level-dependent (BOLD) contrast on field strength using theoretical and experimental models. Numerical simulations using a two-pool exchange model and a surgically prepared dog model were used to assess the SSFP-based myocardial BOLD signal changes at 1.5T and 3.0T. Experimental studies were performed in eight canines with pharmacological vasodilation under various levels of left circumflex coronary artery stenosis. Experimentally obtained BOLD signal changes were correlated against microsphere-based true flow changes. Theoretical results showed that, at 3.0T, relative to 1.5T, a threefold increase in oxygen sensitivity can be expected. Experimental studies in canines showed near similar results-a 2.5 +/- 0.2-fold increase in BOLD sensitivity at 3.0T relative to 1.5T (P &lt; 0.05). Based on the scatter gram of BOLD data and microsphere data, it was found that the minimum regional flow difference that can be detected with SSFP-based myocardial BOLD imaging at 1.5T and 3.0T were 2.9 and 1.6, respectively (P &lt; 0.05). This study demonstrated that SSFP-based myocardial BOLD sensitivity is substantially greater at 3.0T compared with 1.5T. The findings here suggest that SSFP-based myocardial BOLD imaging at 3.0T may have the necessary sensitivity to detect the clinically required minimum flow difference of 2.0.</description><identifier>ISSN: 1053-1807</identifier><identifier>DOI: 10.1002/jmri.21345</identifier><identifier>PMID: 18425840</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Computer Simulation ; Coronary Stenosis - metabolism ; Dogs ; Feasibility Studies ; Linear Models ; Magnetic Resonance Imaging - methods ; Myocardium - metabolism ; Oxygen - metabolism</subject><ispartof>Journal of magnetic resonance imaging, 2008-05, Vol.27 (5), p.1037-1045</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18425840$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dharmakumar, Rohan</creatorcontrib><creatorcontrib>Arumana, Jain Mangalathu</creatorcontrib><creatorcontrib>Tang, Richard</creatorcontrib><creatorcontrib>Harris, Kathleen</creatorcontrib><creatorcontrib>Zhang, Zhouli</creatorcontrib><creatorcontrib>Li, Debiao</creatorcontrib><title>Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines</title><title>Journal of magnetic resonance imaging</title><addtitle>J Magn Reson Imaging</addtitle><description>To examine the dependence of steady-state free-precession (SSFP) -based myocardial blood-oxygen-level-dependent (BOLD) contrast on field strength using theoretical and experimental models. Numerical simulations using a two-pool exchange model and a surgically prepared dog model were used to assess the SSFP-based myocardial BOLD signal changes at 1.5T and 3.0T. Experimental studies were performed in eight canines with pharmacological vasodilation under various levels of left circumflex coronary artery stenosis. Experimentally obtained BOLD signal changes were correlated against microsphere-based true flow changes. Theoretical results showed that, at 3.0T, relative to 1.5T, a threefold increase in oxygen sensitivity can be expected. Experimental studies in canines showed near similar results-a 2.5 +/- 0.2-fold increase in BOLD sensitivity at 3.0T relative to 1.5T (P &lt; 0.05). Based on the scatter gram of BOLD data and microsphere data, it was found that the minimum regional flow difference that can be detected with SSFP-based myocardial BOLD imaging at 1.5T and 3.0T were 2.9 and 1.6, respectively (P &lt; 0.05). This study demonstrated that SSFP-based myocardial BOLD sensitivity is substantially greater at 3.0T compared with 1.5T. The findings here suggest that SSFP-based myocardial BOLD imaging at 3.0T may have the necessary sensitivity to detect the clinically required minimum flow difference of 2.0.</description><subject>Animals</subject><subject>Computer Simulation</subject><subject>Coronary Stenosis - metabolism</subject><subject>Dogs</subject><subject>Feasibility Studies</subject><subject>Linear Models</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Myocardium - metabolism</subject><subject>Oxygen - metabolism</subject><issn>1053-1807</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1UMFOwzAMzQHExuDCB6CcuHWkTdqm3KaJARISSNu9SlO3y9QmJclg-y8-kFQblixb9nt-thG6i8k8JiR53PVWzZOYsvQCTWOS0ijmJJ-ga-d2hJCiYOkVmsScJSlnZIp-F86Bcz1oj02DLbTKaNHh_miksLUKqTkcW9DChwaWW6FbcFhp7LeABwsOtISRKo0NTHvEwnoIwXnQximHf5Tf4kp0IgBrvF6vPrHqRat0i4XHdE7w5mmcZkaurjEcBrBq3CiIw7fo9iftoCmFVhrcDbpsROfg9hxnaLN63ixfo_ePl7fl4j0aUkainCcy5k2TiYIkMiMVT7OMiUoyGgqiyPOKpZLTYLzJKTQcGlpQQXLZpFWR0Rl6OI0drPnag_Nlr5yELlwCZu_KrIhZcBKA92fgvuqhLoewfvhE-f9m-gfT5YAR</recordid><startdate>200805</startdate><enddate>200805</enddate><creator>Dharmakumar, Rohan</creator><creator>Arumana, Jain Mangalathu</creator><creator>Tang, Richard</creator><creator>Harris, Kathleen</creator><creator>Zhang, Zhouli</creator><creator>Li, Debiao</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200805</creationdate><title>Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines</title><author>Dharmakumar, Rohan ; Arumana, Jain Mangalathu ; Tang, Richard ; Harris, Kathleen ; Zhang, Zhouli ; Li, Debiao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p540-782c18ff6a902c60b85664abc43902a977b45c833338f73ef8ef393a07cf5b963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Animals</topic><topic>Computer Simulation</topic><topic>Coronary Stenosis - metabolism</topic><topic>Dogs</topic><topic>Feasibility Studies</topic><topic>Linear Models</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Myocardium - metabolism</topic><topic>Oxygen - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dharmakumar, Rohan</creatorcontrib><creatorcontrib>Arumana, Jain Mangalathu</creatorcontrib><creatorcontrib>Tang, Richard</creatorcontrib><creatorcontrib>Harris, Kathleen</creatorcontrib><creatorcontrib>Zhang, Zhouli</creatorcontrib><creatorcontrib>Li, Debiao</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dharmakumar, Rohan</au><au>Arumana, Jain Mangalathu</au><au>Tang, Richard</au><au>Harris, Kathleen</au><au>Zhang, Zhouli</au><au>Li, Debiao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines</atitle><jtitle>Journal of magnetic resonance imaging</jtitle><addtitle>J Magn Reson Imaging</addtitle><date>2008-05</date><risdate>2008</risdate><volume>27</volume><issue>5</issue><spage>1037</spage><epage>1045</epage><pages>1037-1045</pages><issn>1053-1807</issn><abstract>To examine the dependence of steady-state free-precession (SSFP) -based myocardial blood-oxygen-level-dependent (BOLD) contrast on field strength using theoretical and experimental models. Numerical simulations using a two-pool exchange model and a surgically prepared dog model were used to assess the SSFP-based myocardial BOLD signal changes at 1.5T and 3.0T. Experimental studies were performed in eight canines with pharmacological vasodilation under various levels of left circumflex coronary artery stenosis. Experimentally obtained BOLD signal changes were correlated against microsphere-based true flow changes. Theoretical results showed that, at 3.0T, relative to 1.5T, a threefold increase in oxygen sensitivity can be expected. Experimental studies in canines showed near similar results-a 2.5 +/- 0.2-fold increase in BOLD sensitivity at 3.0T relative to 1.5T (P &lt; 0.05). Based on the scatter gram of BOLD data and microsphere data, it was found that the minimum regional flow difference that can be detected with SSFP-based myocardial BOLD imaging at 1.5T and 3.0T were 2.9 and 1.6, respectively (P &lt; 0.05). This study demonstrated that SSFP-based myocardial BOLD sensitivity is substantially greater at 3.0T compared with 1.5T. The findings here suggest that SSFP-based myocardial BOLD imaging at 3.0T may have the necessary sensitivity to detect the clinically required minimum flow difference of 2.0.</abstract><cop>United States</cop><pmid>18425840</pmid><doi>10.1002/jmri.21345</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1053-1807
ispartof Journal of magnetic resonance imaging, 2008-05, Vol.27 (5), p.1037-1045
issn 1053-1807
language eng
recordid cdi_proquest_miscellaneous_69146910
source Wiley Online Library - AutoHoldings Journals; MEDLINE; Wiley Online Library (Open Access Collection)
subjects Animals
Computer Simulation
Coronary Stenosis - metabolism
Dogs
Feasibility Studies
Linear Models
Magnetic Resonance Imaging - methods
Myocardium - metabolism
Oxygen - metabolism
title Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T03%3A25%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20regional%20myocardial%20oxygenation%20changes%20in%20the%20presence%20of%20coronary%20artery%20stenosis%20with%20balanced%20SSFP%20imaging%20at%203.0%20T:%20theory%20and%20experimental%20evaluation%20in%20canines&rft.jtitle=Journal%20of%20magnetic%20resonance%20imaging&rft.au=Dharmakumar,%20Rohan&rft.date=2008-05&rft.volume=27&rft.issue=5&rft.spage=1037&rft.epage=1045&rft.pages=1037-1045&rft.issn=1053-1807&rft_id=info:doi/10.1002/jmri.21345&rft_dat=%3Cproquest_pubme%3E69146910%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69146910&rft_id=info:pmid/18425840&rfr_iscdi=true