Online clearance measurement in high-efficiency hemodiafiltration

The measurement of ionic dialysance by conductivity variation is an established method in diffusive hemodialysis. To extend the validity of this method for use in highly convective therapies, such as online hemodiafiltration, we derived a new model for the measurement of ionic dialysance. This metho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Kidney international 2007-12, Vol.72 (12), p.1550-1553
Hauptverfasser: Gross, M., Maierhofer, A., Tetta, C., Sénecal, L., Canaud, B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1553
container_issue 12
container_start_page 1550
container_title Kidney international
container_volume 72
creator Gross, M.
Maierhofer, A.
Tetta, C.
Sénecal, L.
Canaud, B.
description The measurement of ionic dialysance by conductivity variation is an established method in diffusive hemodialysis. To extend the validity of this method for use in highly convective therapies, such as online hemodiafiltration, we derived a new model for the measurement of ionic dialysance. This method was validated in a study involving 12 patients on pre- and postdilution online hemodiafiltration under various conditions. Clinically, there was a very good agreement between the dialysance determined by conductivity variation and blood side urea clearance. Neither the dilution modes nor the flow rate of the substitution fluid was found to significantly influence this agreement. Our results show that ionic dialysance can be easily and precisely measured by conductivity variation, and this provides an excellent surrogate for urea clearance even in highly convective therapies.
doi_str_mv 10.1038/sj.ki.5002551
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69007765</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0085253815525891</els_id><sourcerecordid>1391029251</sourcerecordid><originalsourceid>FETCH-LOGICAL-c457t-425484b9392897f896f1bc458d5194f68a2a799673c4f0ffcb3f1073e01fb05c3</originalsourceid><addsrcrecordid>eNp10M1L5DAYwOGwKOv4cdzjShHcW2ffNE2THEX2QxC87J5Dmr5xMrapJq3gf2_cKQ4IewohD2-SHyFfKKwpMPk9bdcPfs0BKs7pJ7KivGIlFZwfkBWA5GXFmTwixyltIe8Vg8_kiAopK1qLFbm6C70PWNgeTTTBYjGgSXPEAcNU-FBs_P2mROe89RjsS7HBYey8cb6fopn8GE7JoTN9wrNlPSF_f_74c_27vL37dXN9dVvamouprCtey7pVTFVSCSdV42ibj2THqapdI01lhFKNYLZ24JxtmaMgGAJ1LXDLTsi33dzHOD7NmCY9-GSx703AcU66UQBCNDzDiw9wO84x5LfpigKl-eMyo3KHbBxTiuj0Y_SDiS-agn4Lq9NWP3i9hM3-fBk6twN2e72UzOByASZZ07u3mD7tnVI1MNVk93Xngply5newv0jszjG3fPYYdfpXHjsf0U66G_1_nvgKRSmcZg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>210112148</pqid></control><display><type>article</type><title>Online clearance measurement in high-efficiency hemodiafiltration</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>ProQuest Central UK/Ireland</source><source>Alma/SFX Local Collection</source><creator>Gross, M. ; Maierhofer, A. ; Tetta, C. ; Sénecal, L. ; Canaud, B.</creator><creatorcontrib>Gross, M. ; Maierhofer, A. ; Tetta, C. ; Sénecal, L. ; Canaud, B.</creatorcontrib><description>The measurement of ionic dialysance by conductivity variation is an established method in diffusive hemodialysis. To extend the validity of this method for use in highly convective therapies, such as online hemodiafiltration, we derived a new model for the measurement of ionic dialysance. This method was validated in a study involving 12 patients on pre- and postdilution online hemodiafiltration under various conditions. Clinically, there was a very good agreement between the dialysance determined by conductivity variation and blood side urea clearance. Neither the dilution modes nor the flow rate of the substitution fluid was found to significantly influence this agreement. Our results show that ionic dialysance can be easily and precisely measured by conductivity variation, and this provides an excellent surrogate for urea clearance even in highly convective therapies.</description><identifier>ISSN: 0085-2538</identifier><identifier>EISSN: 1523-1755</identifier><identifier>DOI: 10.1038/sj.ki.5002551</identifier><identifier>PMID: 17882147</identifier><identifier>CODEN: KDYIA5</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Biological and medical sciences ; clearance ; convection ; dialysis efficiency ; hemodiafiltration ; Hemodiafiltration - methods ; Hemodiafiltration - standards ; Humans ; Kidney Failure, Chronic - therapy ; Medical sciences ; Models, Biological ; Nephrology. Urinary tract diseases ; Reproducibility of Results ; Urea - metabolism</subject><ispartof>Kidney international, 2007-12, Vol.72 (12), p.1550-1553</ispartof><rights>2007 International Society of Nephrology</rights><rights>2008 INIST-CNRS</rights><rights>Copyright Nature Publishing Group Dec 2007</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c457t-425484b9392897f896f1bc458d5194f68a2a799673c4f0ffcb3f1073e01fb05c3</citedby><cites>FETCH-LOGICAL-c457t-425484b9392897f896f1bc458d5194f68a2a799673c4f0ffcb3f1073e01fb05c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/210112148?pq-origsite=primo$$EHTML$$P50$$Gproquest$$H</linktohtml><link.rule.ids>315,782,786,27933,27934,64394,64396,64398,72478</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19940396$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17882147$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gross, M.</creatorcontrib><creatorcontrib>Maierhofer, A.</creatorcontrib><creatorcontrib>Tetta, C.</creatorcontrib><creatorcontrib>Sénecal, L.</creatorcontrib><creatorcontrib>Canaud, B.</creatorcontrib><title>Online clearance measurement in high-efficiency hemodiafiltration</title><title>Kidney international</title><addtitle>Kidney Int</addtitle><description>The measurement of ionic dialysance by conductivity variation is an established method in diffusive hemodialysis. To extend the validity of this method for use in highly convective therapies, such as online hemodiafiltration, we derived a new model for the measurement of ionic dialysance. This method was validated in a study involving 12 patients on pre- and postdilution online hemodiafiltration under various conditions. Clinically, there was a very good agreement between the dialysance determined by conductivity variation and blood side urea clearance. Neither the dilution modes nor the flow rate of the substitution fluid was found to significantly influence this agreement. Our results show that ionic dialysance can be easily and precisely measured by conductivity variation, and this provides an excellent surrogate for urea clearance even in highly convective therapies.</description><subject>Biological and medical sciences</subject><subject>clearance</subject><subject>convection</subject><subject>dialysis efficiency</subject><subject>hemodiafiltration</subject><subject>Hemodiafiltration - methods</subject><subject>Hemodiafiltration - standards</subject><subject>Humans</subject><subject>Kidney Failure, Chronic - therapy</subject><subject>Medical sciences</subject><subject>Models, Biological</subject><subject>Nephrology. Urinary tract diseases</subject><subject>Reproducibility of Results</subject><subject>Urea - metabolism</subject><issn>0085-2538</issn><issn>1523-1755</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNp10M1L5DAYwOGwKOv4cdzjShHcW2ffNE2THEX2QxC87J5Dmr5xMrapJq3gf2_cKQ4IewohD2-SHyFfKKwpMPk9bdcPfs0BKs7pJ7KivGIlFZwfkBWA5GXFmTwixyltIe8Vg8_kiAopK1qLFbm6C70PWNgeTTTBYjGgSXPEAcNU-FBs_P2mROe89RjsS7HBYey8cb6fopn8GE7JoTN9wrNlPSF_f_74c_27vL37dXN9dVvamouprCtey7pVTFVSCSdV42ibj2THqapdI01lhFKNYLZ24JxtmaMgGAJ1LXDLTsi33dzHOD7NmCY9-GSx703AcU66UQBCNDzDiw9wO84x5LfpigKl-eMyo3KHbBxTiuj0Y_SDiS-agn4Lq9NWP3i9hM3-fBk6twN2e72UzOByASZZ07u3mD7tnVI1MNVk93Xngply5newv0jszjG3fPYYdfpXHjsf0U66G_1_nvgKRSmcZg</recordid><startdate>20071201</startdate><enddate>20071201</enddate><creator>Gross, M.</creator><creator>Maierhofer, A.</creator><creator>Tetta, C.</creator><creator>Sénecal, L.</creator><creator>Canaud, B.</creator><general>Elsevier Inc</general><general>Nature Publishing</general><general>Elsevier Limited</general><scope>6I.</scope><scope>AAFTH</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QP</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20071201</creationdate><title>Online clearance measurement in high-efficiency hemodiafiltration</title><author>Gross, M. ; Maierhofer, A. ; Tetta, C. ; Sénecal, L. ; Canaud, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c457t-425484b9392897f896f1bc458d5194f68a2a799673c4f0ffcb3f1073e01fb05c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Biological and medical sciences</topic><topic>clearance</topic><topic>convection</topic><topic>dialysis efficiency</topic><topic>hemodiafiltration</topic><topic>Hemodiafiltration - methods</topic><topic>Hemodiafiltration - standards</topic><topic>Humans</topic><topic>Kidney Failure, Chronic - therapy</topic><topic>Medical sciences</topic><topic>Models, Biological</topic><topic>Nephrology. Urinary tract diseases</topic><topic>Reproducibility of Results</topic><topic>Urea - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gross, M.</creatorcontrib><creatorcontrib>Maierhofer, A.</creatorcontrib><creatorcontrib>Tetta, C.</creatorcontrib><creatorcontrib>Sénecal, L.</creatorcontrib><creatorcontrib>Canaud, B.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Kidney international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gross, M.</au><au>Maierhofer, A.</au><au>Tetta, C.</au><au>Sénecal, L.</au><au>Canaud, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Online clearance measurement in high-efficiency hemodiafiltration</atitle><jtitle>Kidney international</jtitle><addtitle>Kidney Int</addtitle><date>2007-12-01</date><risdate>2007</risdate><volume>72</volume><issue>12</issue><spage>1550</spage><epage>1553</epage><pages>1550-1553</pages><issn>0085-2538</issn><eissn>1523-1755</eissn><coden>KDYIA5</coden><abstract>The measurement of ionic dialysance by conductivity variation is an established method in diffusive hemodialysis. To extend the validity of this method for use in highly convective therapies, such as online hemodiafiltration, we derived a new model for the measurement of ionic dialysance. This method was validated in a study involving 12 patients on pre- and postdilution online hemodiafiltration under various conditions. Clinically, there was a very good agreement between the dialysance determined by conductivity variation and blood side urea clearance. Neither the dilution modes nor the flow rate of the substitution fluid was found to significantly influence this agreement. Our results show that ionic dialysance can be easily and precisely measured by conductivity variation, and this provides an excellent surrogate for urea clearance even in highly convective therapies.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>17882147</pmid><doi>10.1038/sj.ki.5002551</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0085-2538
ispartof Kidney international, 2007-12, Vol.72 (12), p.1550-1553
issn 0085-2538
1523-1755
language eng
recordid cdi_proquest_miscellaneous_69007765
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; ProQuest Central UK/Ireland; Alma/SFX Local Collection
subjects Biological and medical sciences
clearance
convection
dialysis efficiency
hemodiafiltration
Hemodiafiltration - methods
Hemodiafiltration - standards
Humans
Kidney Failure, Chronic - therapy
Medical sciences
Models, Biological
Nephrology. Urinary tract diseases
Reproducibility of Results
Urea - metabolism
title Online clearance measurement in high-efficiency hemodiafiltration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-01T02%3A38%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Online%20clearance%20measurement%20in%20high-efficiency%20hemodiafiltration&rft.jtitle=Kidney%20international&rft.au=Gross,%20M.&rft.date=2007-12-01&rft.volume=72&rft.issue=12&rft.spage=1550&rft.epage=1553&rft.pages=1550-1553&rft.issn=0085-2538&rft.eissn=1523-1755&rft.coden=KDYIA5&rft_id=info:doi/10.1038/sj.ki.5002551&rft_dat=%3Cproquest_cross%3E1391029251%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=210112148&rft_id=info:pmid/17882147&rft_els_id=S0085253815525891&rfr_iscdi=true