Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament
Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and func...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2006-10, Vol.21 (7), p.1012-1016 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1016 |
---|---|
container_issue | 7 |
container_start_page | 1012 |
container_title | The Journal of arthroplasty |
container_volume | 21 |
creator | Sathappan, Sathappan S. Wasserman, Bradley Jaffe, William L. Bong, Matthew Walsh, Michael Di Cesare, Paul E. |
description | Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed. |
doi_str_mv | 10.1016/j.arth.2005.06.018 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68940023</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540305007357</els_id><sourcerecordid>68940023</sourcerecordid><originalsourceid>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</originalsourceid><addsrcrecordid>eNp9kc2O1DAQhC0EYoeFF-CAfOKW0P7LJhKX1fC3YhCr1e7Z8tidHY-SeLAd0DwE74zDjMSNU0utr6vUVYS8ZlAzYM27fW1i3tUcQNXQ1MDaJ2TFlOBVK6F5SlbQtqJSEsQFeZHSHoAxpeRzcsGugF8pKVfk9zfvMsaR3mGah5xo6Olt9KOJR3ofshno1wmRXhejGA6DSflIH5KfHqmhH3zaoaO3YThi3h0HnJDeTAljpr983hXiDi2mVJgQFwO0-S-fiqMvq3WcrTcZ6cY_mhGn_JI8682Q8NV5XpKHTx_v11-qzffPN-vrTWWFkrlyCnhvrTKyA9a5vlPGbEXfbZUVDhm3dmscB2uE6YADcius7JsejTU9CiEuyduT7iGGHzOmrEefLA6DmTDMSTdtJwH4AvITaGNIKWKvD6dwNAO9lKD3eilBLyVoaHQpoRy9OavP2xHdv5Nz6gV4fwKw_PjTY9TJepwsOh9LRtoF_z_9PxwqnGk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68940023</pqid></control><display><type>article</type><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</creator><creatorcontrib>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</creatorcontrib><description>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2005.06.018</identifier><identifier>PMID: 17027544</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee - instrumentation ; dished polyethylene insert ; Female ; Humans ; Knee Prosthesis ; Male ; Middle Aged ; outcome ; Polyethylene ; Posterior Cruciate Ligament ; Prosthesis Design ; Retrospective Studies ; total knee arthroplasty</subject><ispartof>The Journal of arthroplasty, 2006-10, Vol.21 (7), p.1012-1016</ispartof><rights>2006 Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</citedby><cites>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.arth.2005.06.018$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17027544$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sathappan, Sathappan S.</creatorcontrib><creatorcontrib>Wasserman, Bradley</creatorcontrib><creatorcontrib>Jaffe, William L.</creatorcontrib><creatorcontrib>Bong, Matthew</creatorcontrib><creatorcontrib>Walsh, Michael</creatorcontrib><creatorcontrib>Di Cesare, Paul E.</creatorcontrib><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Arthroplasty, Replacement, Knee - instrumentation</subject><subject>dished polyethylene insert</subject><subject>Female</subject><subject>Humans</subject><subject>Knee Prosthesis</subject><subject>Male</subject><subject>Middle Aged</subject><subject>outcome</subject><subject>Polyethylene</subject><subject>Posterior Cruciate Ligament</subject><subject>Prosthesis Design</subject><subject>Retrospective Studies</subject><subject>total knee arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc2O1DAQhC0EYoeFF-CAfOKW0P7LJhKX1fC3YhCr1e7Z8tidHY-SeLAd0DwE74zDjMSNU0utr6vUVYS8ZlAzYM27fW1i3tUcQNXQ1MDaJ2TFlOBVK6F5SlbQtqJSEsQFeZHSHoAxpeRzcsGugF8pKVfk9zfvMsaR3mGah5xo6Olt9KOJR3ofshno1wmRXhejGA6DSflIH5KfHqmhH3zaoaO3YThi3h0HnJDeTAljpr983hXiDi2mVJgQFwO0-S-fiqMvq3WcrTcZ6cY_mhGn_JI8682Q8NV5XpKHTx_v11-qzffPN-vrTWWFkrlyCnhvrTKyA9a5vlPGbEXfbZUVDhm3dmscB2uE6YADcius7JsejTU9CiEuyduT7iGGHzOmrEefLA6DmTDMSTdtJwH4AvITaGNIKWKvD6dwNAO9lKD3eilBLyVoaHQpoRy9OavP2xHdv5Nz6gV4fwKw_PjTY9TJepwsOh9LRtoF_z_9PxwqnGk</recordid><startdate>20061001</startdate><enddate>20061001</enddate><creator>Sathappan, Sathappan S.</creator><creator>Wasserman, Bradley</creator><creator>Jaffe, William L.</creator><creator>Bong, Matthew</creator><creator>Walsh, Michael</creator><creator>Di Cesare, Paul E.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20061001</creationdate><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><author>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Arthroplasty, Replacement, Knee - instrumentation</topic><topic>dished polyethylene insert</topic><topic>Female</topic><topic>Humans</topic><topic>Knee Prosthesis</topic><topic>Male</topic><topic>Middle Aged</topic><topic>outcome</topic><topic>Polyethylene</topic><topic>Posterior Cruciate Ligament</topic><topic>Prosthesis Design</topic><topic>Retrospective Studies</topic><topic>total knee arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sathappan, Sathappan S.</creatorcontrib><creatorcontrib>Wasserman, Bradley</creatorcontrib><creatorcontrib>Jaffe, William L.</creatorcontrib><creatorcontrib>Bong, Matthew</creatorcontrib><creatorcontrib>Walsh, Michael</creatorcontrib><creatorcontrib>Di Cesare, Paul E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sathappan, Sathappan S.</au><au>Wasserman, Bradley</au><au>Jaffe, William L.</au><au>Bong, Matthew</au><au>Walsh, Michael</au><au>Di Cesare, Paul E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2006-10-01</date><risdate>2006</risdate><volume>21</volume><issue>7</issue><spage>1012</spage><epage>1016</epage><pages>1012-1016</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>17027544</pmid><doi>10.1016/j.arth.2005.06.018</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0883-5403 |
ispartof | The Journal of arthroplasty, 2006-10, Vol.21 (7), p.1012-1016 |
issn | 0883-5403 1532-8406 |
language | eng |
recordid | cdi_proquest_miscellaneous_68940023 |
source | MEDLINE; ScienceDirect Journals (5 years ago - present) |
subjects | Adult Aged Aged, 80 and over Arthroplasty, Replacement, Knee - instrumentation dished polyethylene insert Female Humans Knee Prosthesis Male Middle Aged outcome Polyethylene Posterior Cruciate Ligament Prosthesis Design Retrospective Studies total knee arthroplasty |
title | Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T15%3A37%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Midterm%20Results%20of%20Primary%20Total%20Knee%20Arthroplasty%20Using%20a%20Dished%20Polyethylene%20Insert%20with%20a%20Recessed%20or%20Resected%20Posterior%20Cruciate%20Ligament&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Sathappan,%20Sathappan%20S.&rft.date=2006-10-01&rft.volume=21&rft.issue=7&rft.spage=1012&rft.epage=1016&rft.pages=1012-1016&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2005.06.018&rft_dat=%3Cproquest_cross%3E68940023%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68940023&rft_id=info:pmid/17027544&rft_els_id=S0883540305007357&rfr_iscdi=true |