Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament

Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and func...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 2006-10, Vol.21 (7), p.1012-1016
Hauptverfasser: Sathappan, Sathappan S., Wasserman, Bradley, Jaffe, William L., Bong, Matthew, Walsh, Michael, Di Cesare, Paul E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1016
container_issue 7
container_start_page 1012
container_title The Journal of arthroplasty
container_volume 21
creator Sathappan, Sathappan S.
Wasserman, Bradley
Jaffe, William L.
Bong, Matthew
Walsh, Michael
Di Cesare, Paul E.
description Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.
doi_str_mv 10.1016/j.arth.2005.06.018
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68940023</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540305007357</els_id><sourcerecordid>68940023</sourcerecordid><originalsourceid>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</originalsourceid><addsrcrecordid>eNp9kc2O1DAQhC0EYoeFF-CAfOKW0P7LJhKX1fC3YhCr1e7Z8tidHY-SeLAd0DwE74zDjMSNU0utr6vUVYS8ZlAzYM27fW1i3tUcQNXQ1MDaJ2TFlOBVK6F5SlbQtqJSEsQFeZHSHoAxpeRzcsGugF8pKVfk9zfvMsaR3mGah5xo6Olt9KOJR3ofshno1wmRXhejGA6DSflIH5KfHqmhH3zaoaO3YThi3h0HnJDeTAljpr983hXiDi2mVJgQFwO0-S-fiqMvq3WcrTcZ6cY_mhGn_JI8682Q8NV5XpKHTx_v11-qzffPN-vrTWWFkrlyCnhvrTKyA9a5vlPGbEXfbZUVDhm3dmscB2uE6YADcius7JsejTU9CiEuyduT7iGGHzOmrEefLA6DmTDMSTdtJwH4AvITaGNIKWKvD6dwNAO9lKD3eilBLyVoaHQpoRy9OavP2xHdv5Nz6gV4fwKw_PjTY9TJepwsOh9LRtoF_z_9PxwqnGk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68940023</pqid></control><display><type>article</type><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</creator><creatorcontrib>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</creatorcontrib><description>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2005.06.018</identifier><identifier>PMID: 17027544</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee - instrumentation ; dished polyethylene insert ; Female ; Humans ; Knee Prosthesis ; Male ; Middle Aged ; outcome ; Polyethylene ; Posterior Cruciate Ligament ; Prosthesis Design ; Retrospective Studies ; total knee arthroplasty</subject><ispartof>The Journal of arthroplasty, 2006-10, Vol.21 (7), p.1012-1016</ispartof><rights>2006 Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</citedby><cites>FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.arth.2005.06.018$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17027544$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sathappan, Sathappan S.</creatorcontrib><creatorcontrib>Wasserman, Bradley</creatorcontrib><creatorcontrib>Jaffe, William L.</creatorcontrib><creatorcontrib>Bong, Matthew</creatorcontrib><creatorcontrib>Walsh, Michael</creatorcontrib><creatorcontrib>Di Cesare, Paul E.</creatorcontrib><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Arthroplasty, Replacement, Knee - instrumentation</subject><subject>dished polyethylene insert</subject><subject>Female</subject><subject>Humans</subject><subject>Knee Prosthesis</subject><subject>Male</subject><subject>Middle Aged</subject><subject>outcome</subject><subject>Polyethylene</subject><subject>Posterior Cruciate Ligament</subject><subject>Prosthesis Design</subject><subject>Retrospective Studies</subject><subject>total knee arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc2O1DAQhC0EYoeFF-CAfOKW0P7LJhKX1fC3YhCr1e7Z8tidHY-SeLAd0DwE74zDjMSNU0utr6vUVYS8ZlAzYM27fW1i3tUcQNXQ1MDaJ2TFlOBVK6F5SlbQtqJSEsQFeZHSHoAxpeRzcsGugF8pKVfk9zfvMsaR3mGah5xo6Olt9KOJR3ofshno1wmRXhejGA6DSflIH5KfHqmhH3zaoaO3YThi3h0HnJDeTAljpr983hXiDi2mVJgQFwO0-S-fiqMvq3WcrTcZ6cY_mhGn_JI8682Q8NV5XpKHTx_v11-qzffPN-vrTWWFkrlyCnhvrTKyA9a5vlPGbEXfbZUVDhm3dmscB2uE6YADcius7JsejTU9CiEuyduT7iGGHzOmrEefLA6DmTDMSTdtJwH4AvITaGNIKWKvD6dwNAO9lKD3eilBLyVoaHQpoRy9OavP2xHdv5Nz6gV4fwKw_PjTY9TJepwsOh9LRtoF_z_9PxwqnGk</recordid><startdate>20061001</startdate><enddate>20061001</enddate><creator>Sathappan, Sathappan S.</creator><creator>Wasserman, Bradley</creator><creator>Jaffe, William L.</creator><creator>Bong, Matthew</creator><creator>Walsh, Michael</creator><creator>Di Cesare, Paul E.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20061001</creationdate><title>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</title><author>Sathappan, Sathappan S. ; Wasserman, Bradley ; Jaffe, William L. ; Bong, Matthew ; Walsh, Michael ; Di Cesare, Paul E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c354t-d502fcc5a49019df95aab3f9b5c3de12ccbad20ca3a9020e2c3c4f6feacafe333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Arthroplasty, Replacement, Knee - instrumentation</topic><topic>dished polyethylene insert</topic><topic>Female</topic><topic>Humans</topic><topic>Knee Prosthesis</topic><topic>Male</topic><topic>Middle Aged</topic><topic>outcome</topic><topic>Polyethylene</topic><topic>Posterior Cruciate Ligament</topic><topic>Prosthesis Design</topic><topic>Retrospective Studies</topic><topic>total knee arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sathappan, Sathappan S.</creatorcontrib><creatorcontrib>Wasserman, Bradley</creatorcontrib><creatorcontrib>Jaffe, William L.</creatorcontrib><creatorcontrib>Bong, Matthew</creatorcontrib><creatorcontrib>Walsh, Michael</creatorcontrib><creatorcontrib>Di Cesare, Paul E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sathappan, Sathappan S.</au><au>Wasserman, Bradley</au><au>Jaffe, William L.</au><au>Bong, Matthew</au><au>Walsh, Michael</au><au>Di Cesare, Paul E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2006-10-01</date><risdate>2006</risdate><volume>21</volume><issue>7</issue><spage>1012</spage><epage>1016</epage><pages>1012-1016</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92° to 111°. Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>17027544</pmid><doi>10.1016/j.arth.2005.06.018</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2006-10, Vol.21 (7), p.1012-1016
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_68940023
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Adult
Aged
Aged, 80 and over
Arthroplasty, Replacement, Knee - instrumentation
dished polyethylene insert
Female
Humans
Knee Prosthesis
Male
Middle Aged
outcome
Polyethylene
Posterior Cruciate Ligament
Prosthesis Design
Retrospective Studies
total knee arthroplasty
title Midterm Results of Primary Total Knee Arthroplasty Using a Dished Polyethylene Insert with a Recessed or Resected Posterior Cruciate Ligament
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T15%3A37%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Midterm%20Results%20of%20Primary%20Total%20Knee%20Arthroplasty%20Using%20a%20Dished%20Polyethylene%20Insert%20with%20a%20Recessed%20or%20Resected%20Posterior%20Cruciate%20Ligament&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Sathappan,%20Sathappan%20S.&rft.date=2006-10-01&rft.volume=21&rft.issue=7&rft.spage=1012&rft.epage=1016&rft.pages=1012-1016&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2005.06.018&rft_dat=%3Cproquest_cross%3E68940023%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68940023&rft_id=info:pmid/17027544&rft_els_id=S0883540305007357&rfr_iscdi=true