Microplate-based screening methods for the efficient development of sandwich immunoassays

The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one spe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2005-01, Vol.130 (12), p.1580-1588
Hauptverfasser: KIENING, Martin, NIESSNER, Reinhard, WELLER, Michael G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1588
container_issue 12
container_start_page 1580
container_title Analyst (London)
container_volume 130
creator KIENING, Martin
NIESSNER, Reinhard
WELLER, Michael G
description The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one species or when monoclonal antibodies are only available as cell supernatants. Several microplate-based approaches for in situ labeling of detection antibodies were tested, in order to avoid time consuming purification of antibodies for enzyme conjugate synthesis. We investigated labeling with anti-species antibodies and Fab fragments thereof, labeling with protein G and biotinylation of cell supernatants without prior purification. Antibodies against peanut proteins were used as a model and signal-to-blank ratios were used in all cases as a measure of the antibody pair performance. Amongst the investigated approaches, preincubation of the detection antibody with labeled anti-species antibody turned out to be most suitable under our conditions. Diagrams, showing the performance of all possible antibody combinations, were generated with this method and were compared to results obtained with covalently labeled detection antibodies. Finally, a flowchart is presented, suggesting an efficient strategy for the development of highly sensitive sandwich immunoassays.
doi_str_mv 10.1039/b507794j
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68799977</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68799977</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-6d9a36ad6b268cde6e5e89f5aa023286bd1df10f3917905288454eb79071585e3</originalsourceid><addsrcrecordid>eNpFkEtLxDAUhYMozjgK_gLpRnFTTZomaZYy-IIRN7pwVdLkxsnQl72tMv_eDlZmdc-FjwPnI-Sc0RtGub4tBFVKp5sDMmdcprEQSXZI5pRSHidSpDNygrgZX0YFPSYzJpMslULMycdLsF3TlqaHuDAILkLbAdSh_owq6NeNw8g3XdSvIQLvgw1Q95GDbyibttrlxkdoavcT7DoKVTXUjUE0WzwlR96UCGfTXZD3h_u35VO8en18Xt6tYssZ62PptOHSOFkkMrMOJAjItBfG0IQnmSwcc55RzzVTmo67slSkUIxZMZEJ4Aty9dfbds3XANjnVUALZWlqaAbMZaa01kqN4PUfOA5G7MDnbRcq021zRvOdxvxf44heTJ1DUYHbg5O3EbicAIPWlL4ztQ245xSnggvGfwGYenqW</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68799977</pqid></control><display><type>article</type><title>Microplate-based screening methods for the efficient development of sandwich immunoassays</title><source>MEDLINE</source><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>KIENING, Martin ; NIESSNER, Reinhard ; WELLER, Michael G</creator><creatorcontrib>KIENING, Martin ; NIESSNER, Reinhard ; WELLER, Michael G</creatorcontrib><description>The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one species or when monoclonal antibodies are only available as cell supernatants. Several microplate-based approaches for in situ labeling of detection antibodies were tested, in order to avoid time consuming purification of antibodies for enzyme conjugate synthesis. We investigated labeling with anti-species antibodies and Fab fragments thereof, labeling with protein G and biotinylation of cell supernatants without prior purification. Antibodies against peanut proteins were used as a model and signal-to-blank ratios were used in all cases as a measure of the antibody pair performance. Amongst the investigated approaches, preincubation of the detection antibody with labeled anti-species antibody turned out to be most suitable under our conditions. Diagrams, showing the performance of all possible antibody combinations, were generated with this method and were compared to results obtained with covalently labeled detection antibodies. Finally, a flowchart is presented, suggesting an efficient strategy for the development of highly sensitive sandwich immunoassays.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/b507794j</identifier><identifier>PMID: 16284655</identifier><identifier>CODEN: ANALAO</identifier><language>eng</language><publisher>Cambridge: Royal Society of Chemistry</publisher><subject>Analytical chemistry ; Animals ; Antibodies - isolation &amp; purification ; Antigen-Antibody Reactions ; Chemistry ; Exact sciences and technology ; Immunoassay - instrumentation ; Immunoassay - methods ; Immunoglobulin Fab Fragments - immunology ; Mice ; Miscellaneous ; Peanut Agglutinin - immunology</subject><ispartof>Analyst (London), 2005-01, Vol.130 (12), p.1580-1588</ispartof><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-6d9a36ad6b268cde6e5e89f5aa023286bd1df10f3917905288454eb79071585e3</citedby><cites>FETCH-LOGICAL-c311t-6d9a36ad6b268cde6e5e89f5aa023286bd1df10f3917905288454eb79071585e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17305351$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16284655$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KIENING, Martin</creatorcontrib><creatorcontrib>NIESSNER, Reinhard</creatorcontrib><creatorcontrib>WELLER, Michael G</creatorcontrib><title>Microplate-based screening methods for the efficient development of sandwich immunoassays</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one species or when monoclonal antibodies are only available as cell supernatants. Several microplate-based approaches for in situ labeling of detection antibodies were tested, in order to avoid time consuming purification of antibodies for enzyme conjugate synthesis. We investigated labeling with anti-species antibodies and Fab fragments thereof, labeling with protein G and biotinylation of cell supernatants without prior purification. Antibodies against peanut proteins were used as a model and signal-to-blank ratios were used in all cases as a measure of the antibody pair performance. Amongst the investigated approaches, preincubation of the detection antibody with labeled anti-species antibody turned out to be most suitable under our conditions. Diagrams, showing the performance of all possible antibody combinations, were generated with this method and were compared to results obtained with covalently labeled detection antibodies. Finally, a flowchart is presented, suggesting an efficient strategy for the development of highly sensitive sandwich immunoassays.</description><subject>Analytical chemistry</subject><subject>Animals</subject><subject>Antibodies - isolation &amp; purification</subject><subject>Antigen-Antibody Reactions</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Immunoassay - instrumentation</subject><subject>Immunoassay - methods</subject><subject>Immunoglobulin Fab Fragments - immunology</subject><subject>Mice</subject><subject>Miscellaneous</subject><subject>Peanut Agglutinin - immunology</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkEtLxDAUhYMozjgK_gLpRnFTTZomaZYy-IIRN7pwVdLkxsnQl72tMv_eDlZmdc-FjwPnI-Sc0RtGub4tBFVKp5sDMmdcprEQSXZI5pRSHidSpDNygrgZX0YFPSYzJpMslULMycdLsF3TlqaHuDAILkLbAdSh_owq6NeNw8g3XdSvIQLvgw1Q95GDbyibttrlxkdoavcT7DoKVTXUjUE0WzwlR96UCGfTXZD3h_u35VO8en18Xt6tYssZ62PptOHSOFkkMrMOJAjItBfG0IQnmSwcc55RzzVTmo67slSkUIxZMZEJ4Aty9dfbds3XANjnVUALZWlqaAbMZaa01kqN4PUfOA5G7MDnbRcq021zRvOdxvxf44heTJ1DUYHbg5O3EbicAIPWlL4ztQ245xSnggvGfwGYenqW</recordid><startdate>20050101</startdate><enddate>20050101</enddate><creator>KIENING, Martin</creator><creator>NIESSNER, Reinhard</creator><creator>WELLER, Michael G</creator><general>Royal Society of Chemistry</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050101</creationdate><title>Microplate-based screening methods for the efficient development of sandwich immunoassays</title><author>KIENING, Martin ; NIESSNER, Reinhard ; WELLER, Michael G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-6d9a36ad6b268cde6e5e89f5aa023286bd1df10f3917905288454eb79071585e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analytical chemistry</topic><topic>Animals</topic><topic>Antibodies - isolation &amp; purification</topic><topic>Antigen-Antibody Reactions</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Immunoassay - instrumentation</topic><topic>Immunoassay - methods</topic><topic>Immunoglobulin Fab Fragments - immunology</topic><topic>Mice</topic><topic>Miscellaneous</topic><topic>Peanut Agglutinin - immunology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KIENING, Martin</creatorcontrib><creatorcontrib>NIESSNER, Reinhard</creatorcontrib><creatorcontrib>WELLER, Michael G</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KIENING, Martin</au><au>NIESSNER, Reinhard</au><au>WELLER, Michael G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microplate-based screening methods for the efficient development of sandwich immunoassays</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2005-01-01</date><risdate>2005</risdate><volume>130</volume><issue>12</issue><spage>1580</spage><epage>1588</epage><pages>1580-1588</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><coden>ANALAO</coden><abstract>The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one species or when monoclonal antibodies are only available as cell supernatants. Several microplate-based approaches for in situ labeling of detection antibodies were tested, in order to avoid time consuming purification of antibodies for enzyme conjugate synthesis. We investigated labeling with anti-species antibodies and Fab fragments thereof, labeling with protein G and biotinylation of cell supernatants without prior purification. Antibodies against peanut proteins were used as a model and signal-to-blank ratios were used in all cases as a measure of the antibody pair performance. Amongst the investigated approaches, preincubation of the detection antibody with labeled anti-species antibody turned out to be most suitable under our conditions. Diagrams, showing the performance of all possible antibody combinations, were generated with this method and were compared to results obtained with covalently labeled detection antibodies. Finally, a flowchart is presented, suggesting an efficient strategy for the development of highly sensitive sandwich immunoassays.</abstract><cop>Cambridge</cop><pub>Royal Society of Chemistry</pub><pmid>16284655</pmid><doi>10.1039/b507794j</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof Analyst (London), 2005-01, Vol.130 (12), p.1580-1588
issn 0003-2654
1364-5528
language eng
recordid cdi_proquest_miscellaneous_68799977
source MEDLINE; Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Analytical chemistry
Animals
Antibodies - isolation & purification
Antigen-Antibody Reactions
Chemistry
Exact sciences and technology
Immunoassay - instrumentation
Immunoassay - methods
Immunoglobulin Fab Fragments - immunology
Mice
Miscellaneous
Peanut Agglutinin - immunology
title Microplate-based screening methods for the efficient development of sandwich immunoassays
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T00%3A50%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microplate-based%20screening%20methods%20for%20the%20efficient%20development%20of%20sandwich%20immunoassays&rft.jtitle=Analyst%20(London)&rft.au=KIENING,%20Martin&rft.date=2005-01-01&rft.volume=130&rft.issue=12&rft.spage=1580&rft.epage=1588&rft.pages=1580-1588&rft.issn=0003-2654&rft.eissn=1364-5528&rft.coden=ANALAO&rft_id=info:doi/10.1039/b507794j&rft_dat=%3Cproquest_cross%3E68799977%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68799977&rft_id=info:pmid/16284655&rfr_iscdi=true