Cost-effectiveness of basal flow sevoflurane anaesthesia using the komesaroff vaporizer inside the circle system

After ethics committee approval, 51 consenting ASA physical status 1 or 2 adult patients were given basal flow sevoflurane anaesthesia using fresh gas flows of 150 to 300 ml x min(-1) oxygen. A Komesaroff vaporizer was placed on the inspiratory limb of the circle system. Basal flows were introduced...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anaesthesia and intensive care 2005-10, Vol.33 (5), p.609-615
Hauptverfasser: NANDALAN, S. P, ELTRINGHAM, R. J, FAN, Q. W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:After ethics committee approval, 51 consenting ASA physical status 1 or 2 adult patients were given basal flow sevoflurane anaesthesia using fresh gas flows of 150 to 300 ml x min(-1) oxygen. A Komesaroff vaporizer was placed on the inspiratory limb of the circle system. Basal flows were introduced immediately following intravenous induction of anaesthesia. The vaporizer was set to deliver the maximum concentration until the inspired sevoflurane concentration (FSI) reached 3%. The dial was then adjusted to maintain the FSI at 3%. After every 60 minutes, the circuit was washed out with 100% oxygen at a flow rate of 10 l x min(-1) for one minute. The FSI reached 3% after an average of 8.5 (3.8) [mean (SD)] minutes. The trends in FSI and the expired sevoflurane concentrations were significantly different (P
ISSN:0310-057X
1448-0271
DOI:10.1177/0310057X0503300510