Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects

Background: Cored autologous graft from the distal ipsilateral femur has been used to fill osteochondral defects in the talus. There are no studies that compare the articular morphology of potential donor sites on the distal femur with recipient sites on the talus. Methods: Using coronal MRI of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Foot & ankle international 2005-09, Vol.26 (9), p.708-712
Hauptverfasser: Marymont, John V., Shute, Gerald, Zhu, Hongseng, Varner, Kevin E., Paravic, Vibor, Haddad, John L., Noble, Philip C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 712
container_issue 9
container_start_page 708
container_title Foot & ankle international
container_volume 26
creator Marymont, John V.
Shute, Gerald
Zhu, Hongseng
Varner, Kevin E.
Paravic, Vibor
Haddad, John L.
Noble, Philip C.
description Background: Cored autologous graft from the distal ipsilateral femur has been used to fill osteochondral defects in the talus. There are no studies that compare the articular morphology of potential donor sites on the distal femur with recipient sites on the talus. Methods: Using coronal MRI of the talus and distal femur of five matched cadaver, computer reconstructions of the articular surfaces were prepared. From these, six 10-mm in diameter donor sites from the nonweightbearing surfaces of the medial and lateral aspects of the femoral condyles were matched to three recipient sites on the anterior, middle, and posterior aspects of the corresponding medial talus using customized computer software that minimized differences between the articular surfaces of the graft and the talus. After matching the femoral to the talar graft, the average and maximal distances between the surfaces (surface contour) and the average and maximal distances of the offset at the outer 1 mm of the graft periphery (step-off) were determined. Results: For all graft combinations, the average step-off was 0.24 +/−0.03 mm and the maximum 0.60 mm. The average surface contour was 0.32 +/−0.04 mm and the maximum was 1.16 mm. In all cases, the best donor site was from the superolateral femur for any medial talar lesion. Conclusion: In this study of grafts from the femoral condyles, the superolateral femur was the optimal location for an osteochondral graft for any medial talar lesion.
doi_str_mv 10.1177/107110070502600908
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68600458</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_107110070502600908</sage_id><sourcerecordid>68600458</sourcerecordid><originalsourceid>FETCH-LOGICAL-c341t-1d3e220c800859ca26f0d3ce68a84adf2e28f4de48fbeb3f135e1a798bdcf5663</originalsourceid><addsrcrecordid>eNp9kD1v2zAURYmgReMm_QMZAk7d1LynL1Kj4dZpARtZnFmgyUdbhiQ6JDW0vz4UbKBDgU7vDede4B7GHhC-IQrxhCAQAQRUkNcADcgbtsCmLDMhRf0h_QnIZuKWfQ7hBICiwOYTu8UaRVkBLthp5YbzFMl3f8jwrYr62I0H7ixfTtH17uCmwNc0OK96_uyVjYFb53k8Et95UnGgMc74lkyXkJ3qlecvIZLTRzeaOfadLOkY7tlHq_pAX673jr2uf-xWP7PNy_Ov1XKT6aLEmKEpKM9BSwBZNVrltQVTaKqlkqUyNqdc2tJQKe2e9oXFoiJUopF7o21V18Ud-3rpPXv3NlGI7dAFTX2vRkpr2lomWWUlE5hfQO1dCJ5se_bdoPzvFqGdDbf_Gk6hx2v7tB_I_I1clSbg6QIEdaD25CY_prX_q3wHXNuEtQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68600458</pqid></control><display><type>article</type><title>Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects</title><source>MEDLINE</source><source>SAGE Complete A-Z List</source><creator>Marymont, John V. ; Shute, Gerald ; Zhu, Hongseng ; Varner, Kevin E. ; Paravic, Vibor ; Haddad, John L. ; Noble, Philip C.</creator><creatorcontrib>Marymont, John V. ; Shute, Gerald ; Zhu, Hongseng ; Varner, Kevin E. ; Paravic, Vibor ; Haddad, John L. ; Noble, Philip C.</creatorcontrib><description>Background: Cored autologous graft from the distal ipsilateral femur has been used to fill osteochondral defects in the talus. There are no studies that compare the articular morphology of potential donor sites on the distal femur with recipient sites on the talus. Methods: Using coronal MRI of the talus and distal femur of five matched cadaver, computer reconstructions of the articular surfaces were prepared. From these, six 10-mm in diameter donor sites from the nonweightbearing surfaces of the medial and lateral aspects of the femoral condyles were matched to three recipient sites on the anterior, middle, and posterior aspects of the corresponding medial talus using customized computer software that minimized differences between the articular surfaces of the graft and the talus. After matching the femoral to the talar graft, the average and maximal distances between the surfaces (surface contour) and the average and maximal distances of the offset at the outer 1 mm of the graft periphery (step-off) were determined. Results: For all graft combinations, the average step-off was 0.24 +/−0.03 mm and the maximum 0.60 mm. The average surface contour was 0.32 +/−0.04 mm and the maximum was 1.16 mm. In all cases, the best donor site was from the superolateral femur for any medial talar lesion. Conclusion: In this study of grafts from the femoral condyles, the superolateral femur was the optimal location for an osteochondral graft for any medial talar lesion.</description><identifier>ISSN: 1071-1007</identifier><identifier>EISSN: 1944-7876</identifier><identifier>DOI: 10.1177/107110070502600908</identifier><identifier>PMID: 16174501</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Bone Transplantation - methods ; Cadaver ; Computer Simulation ; Female ; Femur - transplantation ; Humans ; Male ; Middle Aged ; Orthopedic Procedures - methods ; Osteochondritis Dissecans - surgery ; Talus - transplantation ; Transplantation, Autologous</subject><ispartof>Foot &amp; ankle international, 2005-09, Vol.26 (9), p.708-712</ispartof><rights>2005 American Orthopaedic Foot &amp; Ankle Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c341t-1d3e220c800859ca26f0d3ce68a84adf2e28f4de48fbeb3f135e1a798bdcf5663</citedby><cites>FETCH-LOGICAL-c341t-1d3e220c800859ca26f0d3ce68a84adf2e28f4de48fbeb3f135e1a798bdcf5663</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/107110070502600908$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/107110070502600908$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21817,27922,27923,43619,43620</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16174501$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Marymont, John V.</creatorcontrib><creatorcontrib>Shute, Gerald</creatorcontrib><creatorcontrib>Zhu, Hongseng</creatorcontrib><creatorcontrib>Varner, Kevin E.</creatorcontrib><creatorcontrib>Paravic, Vibor</creatorcontrib><creatorcontrib>Haddad, John L.</creatorcontrib><creatorcontrib>Noble, Philip C.</creatorcontrib><title>Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects</title><title>Foot &amp; ankle international</title><addtitle>Foot Ankle Int</addtitle><description>Background: Cored autologous graft from the distal ipsilateral femur has been used to fill osteochondral defects in the talus. There are no studies that compare the articular morphology of potential donor sites on the distal femur with recipient sites on the talus. Methods: Using coronal MRI of the talus and distal femur of five matched cadaver, computer reconstructions of the articular surfaces were prepared. From these, six 10-mm in diameter donor sites from the nonweightbearing surfaces of the medial and lateral aspects of the femoral condyles were matched to three recipient sites on the anterior, middle, and posterior aspects of the corresponding medial talus using customized computer software that minimized differences between the articular surfaces of the graft and the talus. After matching the femoral to the talar graft, the average and maximal distances between the surfaces (surface contour) and the average and maximal distances of the offset at the outer 1 mm of the graft periphery (step-off) were determined. Results: For all graft combinations, the average step-off was 0.24 +/−0.03 mm and the maximum 0.60 mm. The average surface contour was 0.32 +/−0.04 mm and the maximum was 1.16 mm. In all cases, the best donor site was from the superolateral femur for any medial talar lesion. Conclusion: In this study of grafts from the femoral condyles, the superolateral femur was the optimal location for an osteochondral graft for any medial talar lesion.</description><subject>Bone Transplantation - methods</subject><subject>Cadaver</subject><subject>Computer Simulation</subject><subject>Female</subject><subject>Femur - transplantation</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Orthopedic Procedures - methods</subject><subject>Osteochondritis Dissecans - surgery</subject><subject>Talus - transplantation</subject><subject>Transplantation, Autologous</subject><issn>1071-1007</issn><issn>1944-7876</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kD1v2zAURYmgReMm_QMZAk7d1LynL1Kj4dZpARtZnFmgyUdbhiQ6JDW0vz4UbKBDgU7vDede4B7GHhC-IQrxhCAQAQRUkNcADcgbtsCmLDMhRf0h_QnIZuKWfQ7hBICiwOYTu8UaRVkBLthp5YbzFMl3f8jwrYr62I0H7ixfTtH17uCmwNc0OK96_uyVjYFb53k8Et95UnGgMc74lkyXkJ3qlecvIZLTRzeaOfadLOkY7tlHq_pAX673jr2uf-xWP7PNy_Ov1XKT6aLEmKEpKM9BSwBZNVrltQVTaKqlkqUyNqdc2tJQKe2e9oXFoiJUopF7o21V18Ud-3rpPXv3NlGI7dAFTX2vRkpr2lomWWUlE5hfQO1dCJ5se_bdoPzvFqGdDbf_Gk6hx2v7tB_I_I1clSbg6QIEdaD25CY_prX_q3wHXNuEtQ</recordid><startdate>20050901</startdate><enddate>20050901</enddate><creator>Marymont, John V.</creator><creator>Shute, Gerald</creator><creator>Zhu, Hongseng</creator><creator>Varner, Kevin E.</creator><creator>Paravic, Vibor</creator><creator>Haddad, John L.</creator><creator>Noble, Philip C.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050901</creationdate><title>Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects</title><author>Marymont, John V. ; Shute, Gerald ; Zhu, Hongseng ; Varner, Kevin E. ; Paravic, Vibor ; Haddad, John L. ; Noble, Philip C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c341t-1d3e220c800859ca26f0d3ce68a84adf2e28f4de48fbeb3f135e1a798bdcf5663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Bone Transplantation - methods</topic><topic>Cadaver</topic><topic>Computer Simulation</topic><topic>Female</topic><topic>Femur - transplantation</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Orthopedic Procedures - methods</topic><topic>Osteochondritis Dissecans - surgery</topic><topic>Talus - transplantation</topic><topic>Transplantation, Autologous</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marymont, John V.</creatorcontrib><creatorcontrib>Shute, Gerald</creatorcontrib><creatorcontrib>Zhu, Hongseng</creatorcontrib><creatorcontrib>Varner, Kevin E.</creatorcontrib><creatorcontrib>Paravic, Vibor</creatorcontrib><creatorcontrib>Haddad, John L.</creatorcontrib><creatorcontrib>Noble, Philip C.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Foot &amp; ankle international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marymont, John V.</au><au>Shute, Gerald</au><au>Zhu, Hongseng</au><au>Varner, Kevin E.</au><au>Paravic, Vibor</au><au>Haddad, John L.</au><au>Noble, Philip C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects</atitle><jtitle>Foot &amp; ankle international</jtitle><addtitle>Foot Ankle Int</addtitle><date>2005-09-01</date><risdate>2005</risdate><volume>26</volume><issue>9</issue><spage>708</spage><epage>712</epage><pages>708-712</pages><issn>1071-1007</issn><eissn>1944-7876</eissn><abstract>Background: Cored autologous graft from the distal ipsilateral femur has been used to fill osteochondral defects in the talus. There are no studies that compare the articular morphology of potential donor sites on the distal femur with recipient sites on the talus. Methods: Using coronal MRI of the talus and distal femur of five matched cadaver, computer reconstructions of the articular surfaces were prepared. From these, six 10-mm in diameter donor sites from the nonweightbearing surfaces of the medial and lateral aspects of the femoral condyles were matched to three recipient sites on the anterior, middle, and posterior aspects of the corresponding medial talus using customized computer software that minimized differences between the articular surfaces of the graft and the talus. After matching the femoral to the talar graft, the average and maximal distances between the surfaces (surface contour) and the average and maximal distances of the offset at the outer 1 mm of the graft periphery (step-off) were determined. Results: For all graft combinations, the average step-off was 0.24 +/−0.03 mm and the maximum 0.60 mm. The average surface contour was 0.32 +/−0.04 mm and the maximum was 1.16 mm. In all cases, the best donor site was from the superolateral femur for any medial talar lesion. Conclusion: In this study of grafts from the femoral condyles, the superolateral femur was the optimal location for an osteochondral graft for any medial talar lesion.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>16174501</pmid><doi>10.1177/107110070502600908</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1071-1007
ispartof Foot & ankle international, 2005-09, Vol.26 (9), p.708-712
issn 1071-1007
1944-7876
language eng
recordid cdi_proquest_miscellaneous_68600458
source MEDLINE; SAGE Complete A-Z List
subjects Bone Transplantation - methods
Cadaver
Computer Simulation
Female
Femur - transplantation
Humans
Male
Middle Aged
Orthopedic Procedures - methods
Osteochondritis Dissecans - surgery
Talus - transplantation
Transplantation, Autologous
title Computerized Matching of Autologous Femoral Grafts for the Treatment of Medial Talar Osteochondral Defects
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T03%3A03%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computerized%20Matching%20of%20Autologous%20Femoral%20Grafts%20for%20the%20Treatment%20of%20Medial%20Talar%20Osteochondral%20Defects&rft.jtitle=Foot%20&%20ankle%20international&rft.au=Marymont,%20John%20V.&rft.date=2005-09-01&rft.volume=26&rft.issue=9&rft.spage=708&rft.epage=712&rft.pages=708-712&rft.issn=1071-1007&rft.eissn=1944-7876&rft_id=info:doi/10.1177/107110070502600908&rft_dat=%3Cproquest_cross%3E68600458%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68600458&rft_id=info:pmid/16174501&rft_sage_id=10.1177_107110070502600908&rfr_iscdi=true