Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry

A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC–MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B 2005-10, Vol.825 (1), p.72-78
Hauptverfasser: Villain, Marion, Concheiro, Marta, Cirimele, Vincent, Kintz, Pascal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 78
container_issue 1
container_start_page 72
container_title Journal of chromatography. B
container_volume 825
creator Villain, Marion
Concheiro, Marta
Cirimele, Vincent
Kintz, Pascal
description A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC–MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zolpidem). The method involves decontamination of hair with methylene chloride, hair cut into small pieces, incubation of 20 mg in phosphate buffer (pH 8.4) in the presence of 1 ng diazepam-d 5 used as internal standard, liquid–liquid extraction with diethyl ether/methylene chloride (10/90) and separation using liquid chromatography–tandem mass spectrometry. The limits of quantification for all benzodiazepines and hypnotics range from 0.5 to 5 pg/mg using a 20-mg hair sample. Linearity is observed from the limit of quantification of each compound to 200 pg/mg ( r 2 > 0.99). Coefficients of variation measured on six points and at two concentrations (10 and 50 pg/mg) range from 5 to 20% for all drugs but one. Extraction recovery, measured at the two same concentrations range from 32 to 76%. These results were found suitable to screen for 16 benzodiazepines in hair and detect them at very low concentrations, making this method suitable to monitor single dose.
doi_str_mv 10.1016/j.jchromb.2004.12.036
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68571683</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S157002320500036X</els_id><sourcerecordid>68571683</sourcerecordid><originalsourceid>FETCH-LOGICAL-c488t-744ccaec41e458324a231fe9d064ff01407249f8684e82a35193134ec6f0f75e3</originalsourceid><addsrcrecordid>eNqFkU1v1DAQhiNERUvhJ4B8gVuy_ortPSFUFYpUiUNB4mZ5nfHGq8RO7Wyl9MSRe_9hf0mzbKQeOHCa0cwzH3rfonhHcEUwEatdtbNtiv2mohjzitAKM_GiOCNKspJJ8evlnNcSl5gyelq8znmHMZFYslfFKRGk5jWtz4o_NzYBBB-2qIexjQ1yMaENhPvYeHMPgw-QkQkNaqchxNHbjHxArfEJmREN21W_RR3cQYc2E-r87d436O9jZozbZIZ2evz90JucUR7AjnMDxjSt_qm8KU6c6TK8XeJ58fPL5Y-Lq_L6-9dvF5-vS8uVGkvJubUGLCfAa8UoN5QRB-sGC-4cJhxLytdOCcVBUcNqsmaEcbDCYSdrYOfFx-PeIcXbPeRR9z5b6DoTIO6zFqqWRCg2g_URtCnmnMDpIfnepEkTrA8W6J1eLNAHCzSherZgnnu_HNhvemiepxbNZ-DDAphsTeeSCdbnZ04SiqU8LPp05GCW485D0tl6CBYan2bddBP9f155ApRPq3c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68571683</pqid></control><display><type>article</type><title>Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Villain, Marion ; Concheiro, Marta ; Cirimele, Vincent ; Kintz, Pascal</creator><creatorcontrib>Villain, Marion ; Concheiro, Marta ; Cirimele, Vincent ; Kintz, Pascal</creatorcontrib><description>A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC–MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zolpidem). The method involves decontamination of hair with methylene chloride, hair cut into small pieces, incubation of 20 mg in phosphate buffer (pH 8.4) in the presence of 1 ng diazepam-d 5 used as internal standard, liquid–liquid extraction with diethyl ether/methylene chloride (10/90) and separation using liquid chromatography–tandem mass spectrometry. The limits of quantification for all benzodiazepines and hypnotics range from 0.5 to 5 pg/mg using a 20-mg hair sample. Linearity is observed from the limit of quantification of each compound to 200 pg/mg ( r 2 &gt; 0.99). Coefficients of variation measured on six points and at two concentrations (10 and 50 pg/mg) range from 5 to 20% for all drugs but one. Extraction recovery, measured at the two same concentrations range from 32 to 76%. These results were found suitable to screen for 16 benzodiazepines in hair and detect them at very low concentrations, making this method suitable to monitor single dose.</description><identifier>ISSN: 1570-0232</identifier><identifier>EISSN: 1873-376X</identifier><identifier>DOI: 10.1016/j.jchromb.2004.12.036</identifier><identifier>PMID: 16154525</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysis ; Analytical, structural and metabolic biochemistry ; Benzodiazepines ; Benzodiazepines - analysis ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Fundamental and applied biological sciences. Psychology ; General pharmacology ; Hair ; Hair - chemistry ; Humans ; Hypnotics ; Hypnotics and Sedatives - analysis ; LC–MS/MS ; Mass Spectrometry - methods ; Medical sciences ; Pharmacology. Drug treatments ; Reference Standards ; Reproducibility of Results ; Sensitivity and Specificity</subject><ispartof>Journal of chromatography. B, 2005-10, Vol.825 (1), p.72-78</ispartof><rights>2005 Elsevier B.V.</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c488t-744ccaec41e458324a231fe9d064ff01407249f8684e82a35193134ec6f0f75e3</citedby><cites>FETCH-LOGICAL-c488t-744ccaec41e458324a231fe9d064ff01407249f8684e82a35193134ec6f0f75e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jchromb.2004.12.036$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,3550,23930,23931,25140,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17120776$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16154525$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Villain, Marion</creatorcontrib><creatorcontrib>Concheiro, Marta</creatorcontrib><creatorcontrib>Cirimele, Vincent</creatorcontrib><creatorcontrib>Kintz, Pascal</creatorcontrib><title>Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry</title><title>Journal of chromatography. B</title><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><description>A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC–MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zolpidem). The method involves decontamination of hair with methylene chloride, hair cut into small pieces, incubation of 20 mg in phosphate buffer (pH 8.4) in the presence of 1 ng diazepam-d 5 used as internal standard, liquid–liquid extraction with diethyl ether/methylene chloride (10/90) and separation using liquid chromatography–tandem mass spectrometry. The limits of quantification for all benzodiazepines and hypnotics range from 0.5 to 5 pg/mg using a 20-mg hair sample. Linearity is observed from the limit of quantification of each compound to 200 pg/mg ( r 2 &gt; 0.99). Coefficients of variation measured on six points and at two concentrations (10 and 50 pg/mg) range from 5 to 20% for all drugs but one. Extraction recovery, measured at the two same concentrations range from 32 to 76%. These results were found suitable to screen for 16 benzodiazepines in hair and detect them at very low concentrations, making this method suitable to monitor single dose.</description><subject>Analysis</subject><subject>Analytical, structural and metabolic biochemistry</subject><subject>Benzodiazepines</subject><subject>Benzodiazepines - analysis</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General pharmacology</subject><subject>Hair</subject><subject>Hair - chemistry</subject><subject>Humans</subject><subject>Hypnotics</subject><subject>Hypnotics and Sedatives - analysis</subject><subject>LC–MS/MS</subject><subject>Mass Spectrometry - methods</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><issn>1570-0232</issn><issn>1873-376X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1v1DAQhiNERUvhJ4B8gVuy_ortPSFUFYpUiUNB4mZ5nfHGq8RO7Wyl9MSRe_9hf0mzbKQeOHCa0cwzH3rfonhHcEUwEatdtbNtiv2mohjzitAKM_GiOCNKspJJ8evlnNcSl5gyelq8znmHMZFYslfFKRGk5jWtz4o_NzYBBB-2qIexjQ1yMaENhPvYeHMPgw-QkQkNaqchxNHbjHxArfEJmREN21W_RR3cQYc2E-r87d436O9jZozbZIZ2evz90JucUR7AjnMDxjSt_qm8KU6c6TK8XeJ58fPL5Y-Lq_L6-9dvF5-vS8uVGkvJubUGLCfAa8UoN5QRB-sGC-4cJhxLytdOCcVBUcNqsmaEcbDCYSdrYOfFx-PeIcXbPeRR9z5b6DoTIO6zFqqWRCg2g_URtCnmnMDpIfnepEkTrA8W6J1eLNAHCzSherZgnnu_HNhvemiepxbNZ-DDAphsTeeSCdbnZ04SiqU8LPp05GCW485D0tl6CBYan2bddBP9f155ApRPq3c</recordid><startdate>20051015</startdate><enddate>20051015</enddate><creator>Villain, Marion</creator><creator>Concheiro, Marta</creator><creator>Cirimele, Vincent</creator><creator>Kintz, Pascal</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20051015</creationdate><title>Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry</title><author>Villain, Marion ; Concheiro, Marta ; Cirimele, Vincent ; Kintz, Pascal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c488t-744ccaec41e458324a231fe9d064ff01407249f8684e82a35193134ec6f0f75e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analysis</topic><topic>Analytical, structural and metabolic biochemistry</topic><topic>Benzodiazepines</topic><topic>Benzodiazepines - analysis</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General pharmacology</topic><topic>Hair</topic><topic>Hair - chemistry</topic><topic>Humans</topic><topic>Hypnotics</topic><topic>Hypnotics and Sedatives - analysis</topic><topic>LC–MS/MS</topic><topic>Mass Spectrometry - methods</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Villain, Marion</creatorcontrib><creatorcontrib>Concheiro, Marta</creatorcontrib><creatorcontrib>Cirimele, Vincent</creatorcontrib><creatorcontrib>Kintz, Pascal</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatography. B</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Villain, Marion</au><au>Concheiro, Marta</au><au>Cirimele, Vincent</au><au>Kintz, Pascal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry</atitle><jtitle>Journal of chromatography. B</jtitle><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><date>2005-10-15</date><risdate>2005</risdate><volume>825</volume><issue>1</issue><spage>72</spage><epage>78</epage><pages>72-78</pages><issn>1570-0232</issn><eissn>1873-376X</eissn><abstract>A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC–MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zolpidem). The method involves decontamination of hair with methylene chloride, hair cut into small pieces, incubation of 20 mg in phosphate buffer (pH 8.4) in the presence of 1 ng diazepam-d 5 used as internal standard, liquid–liquid extraction with diethyl ether/methylene chloride (10/90) and separation using liquid chromatography–tandem mass spectrometry. The limits of quantification for all benzodiazepines and hypnotics range from 0.5 to 5 pg/mg using a 20-mg hair sample. Linearity is observed from the limit of quantification of each compound to 200 pg/mg ( r 2 &gt; 0.99). Coefficients of variation measured on six points and at two concentrations (10 and 50 pg/mg) range from 5 to 20% for all drugs but one. Extraction recovery, measured at the two same concentrations range from 32 to 76%. These results were found suitable to screen for 16 benzodiazepines in hair and detect them at very low concentrations, making this method suitable to monitor single dose.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>16154525</pmid><doi>10.1016/j.jchromb.2004.12.036</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1570-0232
ispartof Journal of chromatography. B, 2005-10, Vol.825 (1), p.72-78
issn 1570-0232
1873-376X
language eng
recordid cdi_proquest_miscellaneous_68571683
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Analysis
Analytical, structural and metabolic biochemistry
Benzodiazepines
Benzodiazepines - analysis
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Fundamental and applied biological sciences. Psychology
General pharmacology
Hair
Hair - chemistry
Humans
Hypnotics
Hypnotics and Sedatives - analysis
LC–MS/MS
Mass Spectrometry - methods
Medical sciences
Pharmacology. Drug treatments
Reference Standards
Reproducibility of Results
Sensitivity and Specificity
title Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography–mass spectrometry/mass spectrometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T05%3A55%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Screening%20method%20for%20benzodiazepines%20and%20hypnotics%20in%20hair%20at%20pg/mg%20level%20by%20liquid%20chromatography%E2%80%93mass%20spectrometry/mass%20spectrometry&rft.jtitle=Journal%20of%20chromatography.%20B&rft.au=Villain,%20Marion&rft.date=2005-10-15&rft.volume=825&rft.issue=1&rft.spage=72&rft.epage=78&rft.pages=72-78&rft.issn=1570-0232&rft.eissn=1873-376X&rft_id=info:doi/10.1016/j.jchromb.2004.12.036&rft_dat=%3Cproquest_cross%3E68571683%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68571683&rft_id=info:pmid/16154525&rft_els_id=S157002320500036X&rfr_iscdi=true