Exhaled breath condensate: methodological recommendations and unresolved questions

Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The European respiratory journal 2005-09, Vol.26 (3), p.523-548
Hauptverfasser: Horvath, I, Hunt, J, Barnes, P. J, On behalf of ATS/ERS Task Force on Exhaled Breath Condensate
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 548
container_issue 3
container_start_page 523
container_title The European respiratory journal
container_volume 26
creator Horvath, I
Hunt, J
Barnes, P. J
On behalf of ATS/ERS Task Force on Exhaled Breath Condensate
description Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1-2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
doi_str_mv 10.1183/09031936.05.00029705
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68544914</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68544914</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-b6110f3488ec818ab58d4c6c837d8ea0ea0330cbfd62a0a3bbdc802b067e462d3</originalsourceid><addsrcrecordid>eNpFkMFq3DAQhkVpaDZp36AUX5qbtzMeS5Z7KyFtCoFCac9Clsaxg2ylkrdt3j7eZMPCwBzm-_-BT4j3CFtETZ-gBcKW1BbkFgCqtgH5SmyQ2rYkAHotNnuk3DOn4iznOwBUNeEbcYoKSTbUbMTPq_-DDeyLLrFdhsLF2fOc7cKfi4mXIfoY4u3obCgSuzhNPHu7jHHOhZ19sZsT5xj-rgV_dpyfDm_FSW9D5neHfS5-f736dXld3vz49v3yy03pasSl7BQi9FRrzU6jtp3UvnbKaWq8ZgvrEIHreq8qC5a6zjsNVQeq4VpVns7FxXPvfYpPz800Zsch2JnjLhulZV23WK9g_Qy6FHNO3Jv7NE42PRgEs3dpXlwakObF5Rr7cOjfdRP7Y-ggbwU-HgCbV0F9srMb85FrQElCeeSG8Xb4NyY2ebIhrLVoON1VypCRFdEj4LWKRg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68544914</pqid></control><display><type>article</type><title>Exhaled breath condensate: methodological recommendations and unresolved questions</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Horvath, I ; Hunt, J ; Barnes, P. J ; On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</creator><creatorcontrib>Horvath, I ; Hunt, J ; Barnes, P. J ; On behalf of ATS/ERS Task Force on Exhaled Breath Condensate ; ATS/ERS Task Force on Exhaled Breath Condensate</creatorcontrib><description>Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1-2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.</description><identifier>ISSN: 0903-1936</identifier><identifier>EISSN: 1399-3003</identifier><identifier>DOI: 10.1183/09031936.05.00029705</identifier><identifier>PMID: 16135737</identifier><language>eng</language><publisher>Leeds: Eur Respiratory Soc</publisher><subject>Biological and medical sciences ; Biomarkers - metabolism ; Breath Tests - methods ; Humans ; Lung Diseases - diagnosis ; Lung Diseases - metabolism ; Medical sciences ; Oxidative Stress - physiology ; Pneumology ; Reproducibility of Results</subject><ispartof>The European respiratory journal, 2005-09, Vol.26 (3), p.523-548</ispartof><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-b6110f3488ec818ab58d4c6c837d8ea0ea0330cbfd62a0a3bbdc802b067e462d3</citedby><cites>FETCH-LOGICAL-c411t-b6110f3488ec818ab58d4c6c837d8ea0ea0330cbfd62a0a3bbdc802b067e462d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17065315$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16135737$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Horvath, I</creatorcontrib><creatorcontrib>Hunt, J</creatorcontrib><creatorcontrib>Barnes, P. J</creatorcontrib><creatorcontrib>On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</creatorcontrib><creatorcontrib>ATS/ERS Task Force on Exhaled Breath Condensate</creatorcontrib><title>Exhaled breath condensate: methodological recommendations and unresolved questions</title><title>The European respiratory journal</title><addtitle>Eur Respir J</addtitle><description>Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1-2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.</description><subject>Biological and medical sciences</subject><subject>Biomarkers - metabolism</subject><subject>Breath Tests - methods</subject><subject>Humans</subject><subject>Lung Diseases - diagnosis</subject><subject>Lung Diseases - metabolism</subject><subject>Medical sciences</subject><subject>Oxidative Stress - physiology</subject><subject>Pneumology</subject><subject>Reproducibility of Results</subject><issn>0903-1936</issn><issn>1399-3003</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMFq3DAQhkVpaDZp36AUX5qbtzMeS5Z7KyFtCoFCac9Clsaxg2ylkrdt3j7eZMPCwBzm-_-BT4j3CFtETZ-gBcKW1BbkFgCqtgH5SmyQ2rYkAHotNnuk3DOn4iznOwBUNeEbcYoKSTbUbMTPq_-DDeyLLrFdhsLF2fOc7cKfi4mXIfoY4u3obCgSuzhNPHu7jHHOhZ19sZsT5xj-rgV_dpyfDm_FSW9D5neHfS5-f736dXld3vz49v3yy03pasSl7BQi9FRrzU6jtp3UvnbKaWq8ZgvrEIHreq8qC5a6zjsNVQeq4VpVns7FxXPvfYpPz800Zsch2JnjLhulZV23WK9g_Qy6FHNO3Jv7NE42PRgEs3dpXlwakObF5Rr7cOjfdRP7Y-ggbwU-HgCbV0F9srMb85FrQElCeeSG8Xb4NyY2ebIhrLVoON1VypCRFdEj4LWKRg</recordid><startdate>20050901</startdate><enddate>20050901</enddate><creator>Horvath, I</creator><creator>Hunt, J</creator><creator>Barnes, P. J</creator><creator>On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</creator><general>Eur Respiratory Soc</general><general>Maney</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050901</creationdate><title>Exhaled breath condensate: methodological recommendations and unresolved questions</title><author>Horvath, I ; Hunt, J ; Barnes, P. J ; On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-b6110f3488ec818ab58d4c6c837d8ea0ea0330cbfd62a0a3bbdc802b067e462d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Biological and medical sciences</topic><topic>Biomarkers - metabolism</topic><topic>Breath Tests - methods</topic><topic>Humans</topic><topic>Lung Diseases - diagnosis</topic><topic>Lung Diseases - metabolism</topic><topic>Medical sciences</topic><topic>Oxidative Stress - physiology</topic><topic>Pneumology</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Horvath, I</creatorcontrib><creatorcontrib>Hunt, J</creatorcontrib><creatorcontrib>Barnes, P. J</creatorcontrib><creatorcontrib>On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</creatorcontrib><creatorcontrib>ATS/ERS Task Force on Exhaled Breath Condensate</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The European respiratory journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Horvath, I</au><au>Hunt, J</au><au>Barnes, P. J</au><au>On behalf of ATS/ERS Task Force on Exhaled Breath Condensate</au><aucorp>ATS/ERS Task Force on Exhaled Breath Condensate</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exhaled breath condensate: methodological recommendations and unresolved questions</atitle><jtitle>The European respiratory journal</jtitle><addtitle>Eur Respir J</addtitle><date>2005-09-01</date><risdate>2005</risdate><volume>26</volume><issue>3</issue><spage>523</spage><epage>548</epage><pages>523-548</pages><issn>0903-1936</issn><eissn>1399-3003</eissn><abstract>Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1-2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.</abstract><cop>Leeds</cop><pub>Eur Respiratory Soc</pub><pmid>16135737</pmid><doi>10.1183/09031936.05.00029705</doi><tpages>26</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0903-1936
ispartof The European respiratory journal, 2005-09, Vol.26 (3), p.523-548
issn 0903-1936
1399-3003
language eng
recordid cdi_proquest_miscellaneous_68544914
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Biological and medical sciences
Biomarkers - metabolism
Breath Tests - methods
Humans
Lung Diseases - diagnosis
Lung Diseases - metabolism
Medical sciences
Oxidative Stress - physiology
Pneumology
Reproducibility of Results
title Exhaled breath condensate: methodological recommendations and unresolved questions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T22%3A02%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exhaled%20breath%20condensate:%20methodological%20recommendations%20and%20unresolved%20questions&rft.jtitle=The%20European%20respiratory%20journal&rft.au=Horvath,%20I&rft.aucorp=ATS/ERS%20Task%20Force%20on%20Exhaled%20Breath%20Condensate&rft.date=2005-09-01&rft.volume=26&rft.issue=3&rft.spage=523&rft.epage=548&rft.pages=523-548&rft.issn=0903-1936&rft.eissn=1399-3003&rft_id=info:doi/10.1183/09031936.05.00029705&rft_dat=%3Cproquest_cross%3E68544914%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68544914&rft_id=info:pmid/16135737&rfr_iscdi=true